Objectives To report the variation in computed tomography perfusion (CTP) arterial input function (AIF) in a multicenter stroke study and to assess the impact this has on CTP results. Methods CTP... Show moreObjectives To report the variation in computed tomography perfusion (CTP) arterial input function (AIF) in a multicenter stroke study and to assess the impact this has on CTP results. Methods CTP datasets from 14 different centers were included from the DUtch acute STroke (DUST) study. The AIF was taken as a direct measure to characterize contrast bolus injection. Statistical analysis was applied to evaluate differences in amplitude, area under the curve (AUC), bolus arrival time (BAT), and time to peak (TTP). To assess the clinical relevance of differences in AIF, CTP acquisitions were simulated with a realistic anthropomorphic digital phantom. Perfusion parameters were extracted by CTP analysis using commercial software (IntelliSpace Portal (ISP), version 10.1) as well as an in-house method based on block-circulant singular value decomposition (bSVD). Results A total of 1422 CTP datasets were included, ranging from 6 to 322 included patients per center. The measured values of the parameters used to characterize the AIF differed significantly with approximate interquartile ranges of 200-750 HU for the amplitude, 2500-10,000 HU center dot s for the AUC, 0-17 s for the BAT, and 10-26 s for the TTP. Mean infarct volumes of the phantom were significantly different between centers for both methods of perfusion analysis. Conclusions Although guidelines for the acquisition protocol are often provided for centers participating in a multicenter study, contrast medium injection protocols still vary. The resulting volumetric differences in infarct core and penumbra may impact clinical decision making in stroke diagnosis. Show less
Speelman, E.S.; Brocx, B.; Wilbers, J.E.; Bie, M.J. de; Ivashchenko, O.; Tank, Y.; Molen, A.J. van der 2019
Purpose Whole-body computed tomography (WBCT) is the standard diagnostic method for evaluating polytrauma patients. When patients are unable to elevate their arms, the arms are placed along the... Show morePurpose Whole-body computed tomography (WBCT) is the standard diagnostic method for evaluating polytrauma patients. When patients are unable to elevate their arms, the arms are placed along the body, which affects the image quality negatively. Aim of this systematic review is to evaluate the influence of below the shoulder arm positions on image quality of WBCT. Methods Literature in PubMed and Scopus databases was systematically searched. Results of the papers were stratified into 4 categories: arms elevated, 1 arm up 1 arm down, arms ventrally supported, arms along the body. A qualitative analysis was performed on subjective image quality and a quantitative analysis on objective quality (image noise). Results Eight studies were included with 1421 participants. Various studies reported significantly higher quality scores with arms elevated, compared to arms along the body. Significant differences in objective image quality were found between the arms elevated and the arms ventrally on support group. The arms ventrally supported group had a significantly higher image quality than the arms along the body group. A statistically significant difference was found in objective image quality between the 1 arm up 1 arm down and arms along the body group. No preferential below the shoulders position could be identified. Conclusion Positioning the arms alongside the body results in a poor image quality. Placing the arms on a pillow ventrally to the chest improves image quality. Interestingly, asymmetrical arm positioning has potential to improve the image quality for patients that are unable to elevate the arms. Show less
Horeweg, N.; Rosmalen, J. van; Heuvelmans, M.; Aalst, C.M. van der; Vliegenthart, R.; Scholten, E.T.; ... ; Oudkerk, M. 2013