Background: It has been proven that intraoperative prostate-specific membrane antigen (PSMA)-targeted radioguidance is valuable for the detection of prostate cancer (PCa) lesions during open... Show moreBackground: It has been proven that intraoperative prostate-specific membrane antigen (PSMA)-targeted radioguidance is valuable for the detection of prostate cancer (PCa) lesions during open surgery. Rapid extension of robot-assisted, minimally invasive surgery has increased the need to make PSMA-radioguided surgery (RGS) robot-compliant.Objective: To evaluate whether the miniaturized DROP-IN gamma probe facilitates translation of PSMA-RGS to robotic surgery in men with recurrent PCa.Design, setting, and participants: This prospective feasibility study included 20 patients with up to three pelvic PCa recurrences (nodal or local) on staging PSMA positron emission tomography (PET) after previous curative-intent therapy.Surgical procedure: Robot-assisted PSMA-RGS using the DROP-IN gamma probe was carried out 19-23 h after intravenous injection of (99m)technetium PSMA-Investigation & Surgery (Tc-99m-PSMA-I&S).Measurements: The primary endpoint was the feasibility of robot-assisted PSMA-RGS. Secondary endpoints were a comparison of the radioactive status (positive or negative) of resected specimens and final histopathology results, prostate-specific antigen (PSA) response following PSMA-RGS, and complications according to the Clavien-Dindo classification.Results and limitations: Using the DROP-IN probe, 19/21 (90%) PSMA-avid lesions could be resected robotically. On a per-lesion basis, the sensitivity and specificity of robot-assisted PSMA-RGS was 86% and 100%, respectively. A prostate-specific antigen (PSA) reduction of >50% and a complete biochemical response (PSA <0.2 ng/ml) were seen in 12/18 (67%) and 4/18 (22%) patients, respectively. During follow-up of up to 15 mo,* Corresponding author. Department of Urology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, Amsterdam 1066 CX, The Netherlands. Tel. +31 205126988. E-mail address: h.d.barros@nki.nl (H.A. de Barros) Show less
Background: With the rise of prostate-specific membrane antigen (PSMA) radioguided surgery, which is performed using a microdosing regime, demand for visual target confirmation via fluorescence... Show moreBackground: With the rise of prostate-specific membrane antigen (PSMA) radioguided surgery, which is performed using a microdosing regime, demand for visual target confirmation via fluorescence guidance is growing. While proven very effective for radiotracers, microdosing approaches the detection limit for fluorescence imaging. Thus, utility will be highly dependent on the tracer performance, the sensitivity of the fluorescence camera used, and the degree of background signal. Using a porcine model the ability to perform robot-assisted radical prostatectomy under fluorescence guidance using the bimodal or rather hybrid PSMA tracer (Tc-99m-EuK-(SO3)Cy5-mas(3)) was studied, while employing the tracer in a microdosing regime. This was followed by ex vivo evaluation in surgical specimens obtained from prostate cancer patients. Results: T-50% blood and T-50% urine were reached at 85 min and 390 min, in, respectively, blood and urine. Surgical fluorescence imaging allowed visualization of the prostate gland based on the basal PSMA-expression in porcine prostate. Together, in vivo visualization of the prostate and urinary excretion suggests at least an interval of > 7 h between tracer administration and surgery. Confocal microscopy of excised tissues confirmed tracer uptake in kidney and prostate, which was confirmed with PSMA IHC. No fluorescence was detected in other excised tissues. Tumor identification based on ex vivo fluorescence imaging of human prostate cancer specimens correlated with PSMA IHC. Conclusion: Intraoperative PSMA-mediated fluorescence imaging with a microdosing approach was shown to be feasible. Furthermore, EuK-(SO3)Cy5-mas(3) allowed tumor identification in human prostate samples, underlining the translational potential of this novel tracer. Trial registration Approval for use of biological material for research purposes was provided by the Translational Research Board of the Netherlands Cancer Institute-Antoni van Leeuwenhoek hospital (NKI-AvL) under reference IRBm19-273 (22/10/2019). Show less
Collamati, F.; Oosterom, M.N. van; Simoni, M. de; Faccini, R.; Fischetti, M.; Terracciano, C.M.; ... ; Morganti, S. 2020
Background Recently, a flexible DROP-IN gamma-probe was introduced for robot-assisted radioguided surgery, using traditional low-energy SPECT-isotopes. In parallel, a novel approach to achieve... Show moreBackground Recently, a flexible DROP-IN gamma-probe was introduced for robot-assisted radioguided surgery, using traditional low-energy SPECT-isotopes. In parallel, a novel approach to achieve sensitive radioguidance using beta-emitting PET isotopes has been proposed. Integration of these two concepts would allow to exploit the use of PET tracers during robot-assisted tumor-receptor-targeted. In this study, we have engineered and validated the performance of a novel DROP-IN beta particle (DROP-IN beta) detector. Methods Seven prostate cancer patients with PSMA-PET positive tumors received an additional intraoperative injection of similar to 70 MBq(68)Ga-PSMA-11, followed by robot-assisted prostatectomy and extended pelvic lymph node dissection. The surgical specimens from these procedures were used to validate the performance of our DROP-IN(beta)probe prototype, which merged a scintillating detector with a housing optimized for a 12-mm trocar and prograsp instruments. Results After optimization of the detector and probe housing via Monte Carlo simulations, the resulting DROP-IN(beta)probe prototype was tested in a robotic setting. In the ex vivo setting, the probe-positioned by the robot-was able to identify(68)Ga-PSMA-11 containing hot-spots in the surgical specimens: signal-to-background (S/B) was > 5 when pathology confirmed that the tumor was located < 1 mm below the specimen surface.Ga-68-PSMA-11 containing (and PET positive) lymph nodes, as found in two patients, were also confirmed with the DROP-IN(beta)probe (S/B > 3). The rotational freedom of the DROP-IN design and the ability to manipulate the probe with the prograsp tool allowed the surgeon to perform autonomous beta-tracing. Conclusions This study demonstrates the feasibility of beta-radioguided surgery in a robotic context by means of a DROP-IN(beta)detector. When translated to an in vivo setting in the future, this technique could provide a valuable tool in detecting tumor remnants on the prostate surface and in confirmation of PSMA-PET positive lymph nodes. Show less
In the quest for precision surgery, this thesis introduces several novel detection and navigation modalities for the localization of cancer-related tissues in the operating room. The engineering... Show moreIn the quest for precision surgery, this thesis introduces several novel detection and navigation modalities for the localization of cancer-related tissues in the operating room. The engineering efforts have focused on image-guided surgery modalities that use the complementary tracer signatures of nuclear and fluorescence radiation. The first part of the thesis covers the use of “GPS-like” navigation concepts to navigate fluorescence cameras during surgery, based on SPECT images of the patient. The second part of the thesis introduces several new imaging modalities such as a hybrid 3D freehand Fluorescence and freehand SPECT imaging and navigation device. Furthermore, to improve the detection of radioactive tracer-emissions during robot-assisted laparoscopic surgery, a tethered DROP-IN gamma probe is introduced. The clinical indications that are used to evaluate the new technologies were all focused on sentinel lymph node procedures in urology (i.e. prostate and penile cancer). Nevertheless, all presented techniques are of such a nature, that they can be applied to different surgical indications, including sentinel lymph node and tumor-receptor-targeted procedures, localization the primary tumor and metastatic spread. This will hopefully contribute towards more precise, less invasive and more effective surgical procedures in the field of oncology. Show less
KleinJan, G.H.; Berg, N.S. van den; Jong, J. de; Wit, E.M.; Thygessen, H.; Vegt, E.; ... ; Leeuwen, F.W.B. van 2016