Background and aims: Accurate classification of plaque composition is essential for treatment planning. Intravascular ultrasound (IVUS) has limited efficacy in assessing tissue types, while near... Show moreBackground and aims: Accurate classification of plaque composition is essential for treatment planning. Intravascular ultrasound (IVUS) has limited efficacy in assessing tissue types, while near-infrared spectroscopy (NIRS) provides complementary information to IVUS but lacks depth information. The aim of this study is to train and assess the efficacy of a machine learning classifier for plaque component classification that relies on IVUS echogenicity and NIRS-signal, using histology as reference standard. Methods: Matched NIRS-IVUS and histology images from 15 cadaveric human coronary arteries were analyzed (10 vessels were used for training and 5 for testing). Fibrous/pathological intimal thickening (F-PIT), early necrotic core (ENC), late necrotic core (LNC), and calcific tissue regions-of-interest were detected on histology and superimposed onto IVUS frames. The pixel intensities of these tissue types from the training set were used to train a J48 classifier for plaque characterization (ECHO-classification). To aid differentiation of F-PIT from necrotic cores, the NIRS-signal was used to classify non-calcific pixels outside yellow-spot regions as F-PIT (ECHO-NIRS classification). The performance of ECHO and ECHO-NIRS classifications were validated against histology. Results: 262 matched frames were included in the analysis (162 constituted the training set and 100 the test set). The pixel intensities of F-PIT and ENC were similar and thus these two tissues could not be differentiated by echogenicity. With ENC and LNC as a single class, ECHO-classification showed good agreement with histology for detecting calcific and F-PIT tissues but had poor efficacy for necrotic cores (recall 0.59 and precision 0.29). Similar results were found when F-PIT and ENC were treated as a single class (recall and precision for LNC 0.78 and 0.33, respectively). ECHO-NIRS classification improved necrotic core and LNC detection, resulting in an increase of the overall accuracy of both models, from 81.4% to 91.8%, and from 87.9% to 94.7%, respectively. Comparable performance of the two models was seen in the test set where the overall accuracy of ECHO-NIRS classification was 95.0% and 95.5%, respectively. Conclusions: The combination of echogenicity with NIRS-signal appears capable of overcoming limitations of echogenicity, enabling more accurate characterization of plaque components. Show less
Aims: The aim of this study is to develop and validate a deep learning (DL) methodology capable of automated and accurate segmentation of intravascular ultrasound (IVUS) image sequences in real... Show moreAims: The aim of this study is to develop and validate a deep learning (DL) methodology capable of automated and accurate segmentation of intravascular ultrasound (IVUS) image sequences in real-time. Methods and results: IVUS segmentation was performed by two experts who manually annotated the external elastic membrane (EEM) and lumen borders in the end-diastolic frames of 197 IVUS sequences portraying the native coronary arteries of 65 patients. The IVUS sequences of 177 randomly-selected vessels were used to train and optimise a novel DL model for the segmentation of IVUS images. Validation of the developed methodology was performed in 20 vessels using the estimations of two expert analysts as the reference standard. The mean difference for the EEM, lumen and plaque area between the DL-methodology and the analysts was <0.23mm2 (standard deviation <0.85mm2), while the Hausdorff and mean distance differences for the EEM and lumen borders was <0.19 mm (standard deviation<0.17 mm). The agreement between DL and experts was similar to experts' agreement (Williams Index ranges: 0.754-1.061) with similar results in frames portraying calcific plaques or side branches. Conclusions: The developed DL-methodology appears accurate and capable of segmenting high-resolution realworld IVUS datasets. These features are expected to facilitate its broad adoption and enhance the applications of IVUS in clinical practice and research. Show less
Coronary luminal dimensions change during the cardiac cycle. However, contemporary volumetric intravascular ultrasound (IVUS) analysis is performed in non-gated images as existing methods to... Show moreCoronary luminal dimensions change during the cardiac cycle. However, contemporary volumetric intravascular ultrasound (IVUS) analysis is performed in non-gated images as existing methods to acquire gated or to retrospectively gate IVUS images have failed to dominate in research. We developed a novel deep learning (DL)-methodology for end-diastolic frame detection in IVUS and compared its efficacy against expert analysts and a previously established methodology using electrocardiographic (ECG)-estimations as reference standard. Near-infrared spectroscopy-IVUS (NIRS-IVUS) data were prospectively acquired from 20 coronary arteries and co-registered with the concurrent ECG-signal to identify end-diastolic frames. A DL-methodology which takes advantage of changes in intensity of corresponding pixels in consecutive NIRS-IVUS frames and consists of a network model designed in a bidirectional gated-recurrent-unit (Bi-GRU) structure was trained to detect end-diastolic frames. The efficacy of the DL-methodology in identifying end-diastolic frames was compared with two expert analysts and a conventional image-based (CIB)-methodology that relies on detecting vessel movement to estimate phases of the cardiac cycle. A window of +/- 100 ms from the ECG estimations was used to define accurate end-diastolic frames detection. The ECG-signal identified 3,167 end-diastolic frames. The mean difference between DL and ECG estimations was 3 +/- 112 ms while the mean differences between the 1st-analyst and ECG, 2nd-analyst and ECG and CIB-methodology and ECG were 86 +/- 192 ms, 78 +/- 183 ms and 59 +/- 207 ms, respectively. The DL-methodology was able to accurately detect 80.4%, while the two analysts and the CIB-methodology detected 39.0%, 43.4% and 42.8% of end-diastolic frames, respectively (P < 0.05). The DL-methodology can identify NIRS-IVUS end-diastolic frames accurately and should be preferred over expert analysts and CIB-methodologies, which have limited efficacy. Show less