Purpose To assess whether combined analysis of specular microscopy and Scheimpflug imaging improves detection of an upcoming allograft rejection following Descemet membrane endothelial keratoplasty... Show morePurpose To assess whether combined analysis of specular microscopy and Scheimpflug imaging improves detection of an upcoming allograft rejection following Descemet membrane endothelial keratoplasty (DMEK).Methods Retrospective analysis of 22 eyes that had developed a clinical proven allograft rejection 28 (+/- 22) months (range: 4-84 months) after DMEK. Specular microscopy and Scheimpflug images routinely made after DMEK were retrospectively analysed for changes in endothelial cell morphology (e.g. nuclear activation), cell density (>10%) and pachymetry (>7%), and/or the presence of subclinical keratic precipitates. The same parameters were evaluated for 22 control eyes matched for age, gender and surgery indication.Results A total of 20/22 eyes (91%) showed detectable changes 0.25-75 months before allograft rejection became clinically manifest: 13/22 (59%) showed both specular microscopy and Scheimpflug imaging changes; 5/22 (23%) only had changes on Scheimpflug imaging; and 2/22 (9%) only had specular microscopy changes. In 18/22 (82%) and 14/22 (64%) eyes, subclinical keratic precipitates and endothelial cell morphology changes could be detected, respectively. A total of 11/22 (50%) eyes concurrently showed a >10% drop in endothelial cell density and 4/22 (18%) a >7% pachymetry increase. Of the control eyes, 7/22 (32%) showed changes with specular microscopy but not with Scheimpflug imaging.Conclusions Combined analysis of specular microscopy and Scheimpflug imaging may allow recognizing an upcoming allograft rejection in over 90% of eyes and up to 6 years before rejection becomes clinically manifest. Early recognition of eyes at risk may allow for targeted intensified steroid treatment to prevent endothelial cell damage associated with rejection. Show less
Introduction: During our clinical practice and research, we encountered an interchangeability problem when using the SP-2000P and SP-3000P TopCon corneal specular microscopes (CSMs) (TopCon Medical... Show moreIntroduction: During our clinical practice and research, we encountered an interchangeability problem when using the SP-2000P and SP-3000P TopCon corneal specular microscopes (CSMs) (TopCon Medical Systems, Tokyo, Japan) regarding the endothelial cell count (ECC). We describe a method to improve interchangeability between these CSMs.Methods: Five consecutive good-quality endothelial cell photographs were obtained in 22 eyes of 11 subjects. An ECC comparison between the two CSMs was performed after (I) gauging and calibration by the manufacturer, (II) adjustment of the magnification, (III) correction after external horizontal and vertical calibration.Results: There was a statistically significant difference between the ECC of the SP-2000P and SP-3000P at the start. The SP-2000P counted an average of 500 cells/mm(2) more than the SP-3000P (p=0.00). After correction for magnification and determining a correction factor based on external calibration, the difference between the ECC of the SP-2000P and the SP-3000P was then found to be 0.4 cells/mm(2) and was not statistically significant (p=0.98).Discussion: We propose a method for improving interchangeability, which involves checking magnification settings, re-checking magnification calibration with external calibration devices, and then calculating correction factors. This method can be applied to various specular or confocal microscopes and their associated endothelial cell analysis software packages to be able to keep performing precise endothelial cell counts and to enable comparison of ECCs when a CSM needs to be replaced or when results from different microscopes need to be compared. Show less