Background: The IMI-APPROACH cohort is an exploratory, 5-centre, 2-year prospective follow-up study of knee osteoarthritis (OA). Aim was to describe baseline multi-tissue semiquantitative MRI... Show moreBackground: The IMI-APPROACH cohort is an exploratory, 5-centre, 2-year prospective follow-up study of knee osteoarthritis (OA). Aim was to describe baseline multi-tissue semiquantitative MRI evaluation of index knees and to describe change for different MRI features based on number of subregion-approaches and change in maximum grades over a 24-month period.Methods: MRIs were acquired using 1.5 T or 3 T MRI systems and assessed using the semi-quantitative MRI OA Knee Scoring (MOAKS) system. MRIs were read at baseline and 24-months for cartilage damage, bone marrow lesions (BML), osteophytes, meniscal damage and extrusion, and Hoffa- and effusion-synovitis. In descriptive fashion, the frequencies of MRI features at baseline and change in these imaging biomarkers over time are presented for the entire sample in a subregional and maximum score approach for most features. Differences between knees without and with structural radiographic (R) OA are analyzed in addition.Results: Two hundred eighty-nine participants had readable baseline MRI examinations. Mean age was 66.6 +/- 7.1 years and participants had a mean BMI of 28.1 +/- 5.3 kg/m(2). The majority (55.3%) of included knees had radiographic OA. Any change in total cartilage MOAKS score was observed in 53.1% considering full-grade changes only, and in 73.9% including full-grade and within-grade changes. Any medial cartilage progression was seen in 23.9% and any lateral progression on 22.1%. While for the medial and lateral compartments numbers of subregions with improvement and worsening of BMLs were very similar, for the PFJ more improvement was observed compared to worsening (15.5% vs. 9.0%). Including within grade changes, the number of knees showing BML worsening increased from 42.2% to 55.6%. While for some features 24-months change was rare, frequency of change was much more common in knees with vs. without ROA (e.g. worsening of total MOAKS score cartilage in 68.4% of ROA knees vs. 36.7% of no-ROA knees, and 60.7% vs. 21.8% for an increase in maximum BML score per knee).Conclusions: A wide range of MRI-detected structural pathologies was present in the IMI-APPROACH cohort. Baseline prevalence and change of features was substantially more common in the ROA subgroup compared to the knees without ROA. Show less
Willik, E.M. van der; Breda, F. van; Jaarsveld, B.C. van; Putte, M. van de; Jetten, I.W.; Dekker, F.W.; ... ; Terwee, C.B. 2022
Background The Patient-Reported Outcomes Measurement Information System (PROMIS (R)) has been recommended for computerized adaptive testing (CAT) of health-related quality of life. This study... Show moreBackground The Patient-Reported Outcomes Measurement Information System (PROMIS (R)) has been recommended for computerized adaptive testing (CAT) of health-related quality of life. This study compared the content, validity, and reliability of seven PROMIS CATs to the 12-item Short-Form Health Survey (SF-12) in patients with advanced chronic kidney disease.Methods Adult patients with chronic kidney disease and an estimated glomerular filtration rate under 30 mL/min/1.73 m(2) who were not receiving dialysis treatment completed seven PROMIS CATs (assessing physical function, pain interference, fatigue, sleep disturbance, anxiety, depression, and the ability to participate in social roles and activities), the SF-12, and the PROMIS Pain Intensity single item and Dialysis Symptom Index at inclusion and 2 weeks. A content comparison was performed between PROMIS CATs and the SF-12. Construct validity of PROMIS CATs was assessed using Pearson's correlations. We assessed the test-retest reliability of all patient-reported outcome measures by calculating the intraclass correlation coefficient and minimal detectable change.Results In total, 207 patients participated in the study. A median of 45 items (10 minutes) were completed for PROMIS CATs. All PROMIS CATs showed evidence of sufficient construct validity. PROMIS CATs, most SF-12 domains and summary scores, and Dialysis Symptom Index showed sufficient test-retest reliability (intraclass correlation coefficient >= 0.70). PROMIS CATs had a lower minimal detectable change compared with the SF-12 (range, 5.7-7.4 compared with 11.3-21.7 across domains, respectively).Conclusion PROMIS CATs showed sufficient construct validity and test-retest reliability in patients with advanced chronic kidney disease. PROMIS CATs required more items but showed better reliability than the SF-12. Future research is needed to investigate the feasibility of PROMIS CATs for routine nephrology care. Show less
Stadt, L.A. van de; Kroon, F.P.B.; Rosendaal, F.R.; Heijde, D. van der; Reijnierse, M.; Riyazi, N.; ... ; Kortekaas, M.C. 2021
Objectives Agreement between real-time and static ultrasonography has not been studied in musculoskeletal diseases. We studied this agreement in inflammatory hand OA. Methods Ultrasonography was... Show moreObjectives Agreement between real-time and static ultrasonography has not been studied in musculoskeletal diseases. We studied this agreement in inflammatory hand OA. Methods Ultrasonography was performed blinded to clinical information of 30 joints of 75 patients with hand OA, treated with prednisolone in a randomized placebo-controlled double-blind trial. Images were scored real-time at acquisition and stored images were scored static (paired in known chronological order) for inflammatory features and osteophytes (score 0-3). Agreement between methods was studied at joint level with quadratic weighted kappa. At patient level intra-class correlations (ICC) of sum scores and change in sum-scores (delta baseline-week 6) were calculated. Responsiveness of scoring methods was analysed with generalized estimating equations (GEE) with treatment as independent and ultrasonography findings as dependent variable. Results Agreement at baseline was good to excellent at joint level (kappa 0.72-0.88) and moderate to excellent at patient level (ICC 0.58-0.91). Agreement for change in sum scores was poor to fair for synovial thickening and effusion (ICC 0.18 and 0.34, respectively), while excellent for Doppler signal (ICC 0.80). Real-time ultrasonography discriminated between prednisolone and placebo with a mean between-group difference of synovial thickening of -2.5 (95% CI: -4.7, -0.3). Static ultrasonography did not show a decrease in synovial thickening. Conclusion While cross-sectional agreement between real-time and static ultrasonography is good, static ultrasonography measurement of synovial thickening did not show responsiveness to prednisone therapy while real-time ultrasonography did. Therefore, when ultrasonography is used in clinical trials, real-time dynamic scoring should remain the standard for now. Show less
Objective: Injury coding is well known for lack of completeness and accuracy. The objective of this study was to perform a nationwide assessment of accuracy and reliability on Abbreviated Injury... Show moreObjective: Injury coding is well known for lack of completeness and accuracy. The objective of this study was to perform a nationwide assessment of accuracy and reliability on Abbreviated Injury Scale (AIS) coding by Dutch Trauma Registry (DTR) coders and to determine the effect on Injury Severity Score (ISS). Additionally, the coders' characteristics were surveyed.Methods: Three fictional trauma cases were presented to all Dutch trauma coders in a nationwide survey (response rate 69%). The coders were asked to extract and code the cases' injuries according to the AIS manual (version 2005, update 2008). Reference standard was set by three highly experienced coders. Summary statistics were used to describe the registered AIS codes and ISS distribution. The primary outcome measures were accuracy of injury coding and inter-rater agreement on AIS codes. Secondary outcome measures were characteristics of coders: profession, work setting, experience in injury coding and training level in injury coding.Results: The total number of different AIS codes used to describe 14 separate injuries in the three cases was 89. Mean accuracy per AIS code was 42.2% (range 2.4-92.7%). Mean accuracy on number of AIS codes was 23%. Overall inter-rater agreement per AIS code was 49.1% (range 2.4-92.7%). The number of assigned AIS codes varied between 0 and 18 per injury. Twenty-seven percentage of injuries were overlooked. ISS was correctly scored in 42.4%. In 31.7%, the AIS coding of the two more complex cases led to incorrect classification of the patient as ISS < 16 or ISS >= 16. Half (47%) of the coders had no (para)medical degree, 26% were working in level I trauma centers, 37% had less than 2 years of experience and 40% had no training in AIS coding.Conclusions: Accuracy of and inter-rater agreement on AIS injury scoring by DTR coders is limited. This may in part be due to the heterogeneous backgrounds and training levels of the coders. As a result of the inconsistent coding, the number of major trauma patients in the DTR may be over- or underestimated. Conclusions based on DTR data should therefore be drawn with caution. Show less
Healthy individuals perform a task such as hitting the head of a nail with an infinite coordination spectrum. This motor redundancy is healthy and allows for learning through exploration and... Show moreHealthy individuals perform a task such as hitting the head of a nail with an infinite coordination spectrum. This motor redundancy is healthy and allows for learning through exploration and uniform load distribution across muscles. Assessing movement complexity within repetitive movement trajectories may provide insight into the available motor redundancy during aging. We quantified complexity of repetitive arm elevation trajectories in the aging shoulder and assessed test-retest reliability of this quantification. In a cross-sectional study using 3D-electromagnetic tracking, 120 asymptomatic subjects, aged between 18 and 70 years performed repetitive abduction and forward/anteflexion movements. Movement complexity was calculated using the Approximate Entropy (ApEn-value): [0,2], where lower values indicate reduced complexity. Thirty-three participants performed the protocol twice, to determine reliability (intraclass correlation coefficient [ICC]). The association between age and ApEn was corrected for task characteristics (e.g., sample length) with multiple linear regression analysis. Reproducibility was determined using scatter plots and ICC's. Higher age was associated with lower ApEn-values during abduction (unstandardized estimate: -0.003/year; 95% confidence interval: [-0.005; -0.002]; p < .001). ICC's revealed poor to good reliability depending on differences in sample length between repeated measurements. The results may imply more stereotype movement during abduction in the ageing shoulder, making this movement prone to the development of shoulder complaints. Future studies may investigate the pathophysiology and clinical course of shoulder complaints by assessment of movement complexity. To this end, the ApEn-value calculated over repetitive movement trajectories may be used, although biasing factors such as sample length should be taken into account. Show less
OBJECTIVE The 6-minute walking test (6WT) is used to determine restrictions in a subject's 6-minute walking distance (6WD) due to lumbar degenerative disc disease. To facilitate simple and... Show moreOBJECTIVE The 6-minute walking test (6WT) is used to determine restrictions in a subject's 6-minute walking distance (6WD) due to lumbar degenerative disc disease. To facilitate simple and convenient patient self-measurement, a free and reliable smartphone app using Global Positioning System coordinates was previously designed. The authors aimed to determine normative values for app-based 6WD measurements.METHODS The maximum 6WD was determined three times using app-based measurement in a sample of 330 volunteers without previous spine surgery or current spine-related disability, recruited at 8 centers in 5 countries (mean subject age 44.2 years, range 16-91 years; 48.5% male; mean BMI 24.6 kg/m(2), range 16.3-40.2 kg/m(2); 67.9% working; 14.2% smokers). Subjects provided basic demographic information, including comorbidities and patient-reported outcome measures (PROMs): visual analog scale (VAS) for both low-back and lower-extremity pain, Core Outcome Measures Index (COMI), Zurich Claudication Questionnaire (ZCQ), and subjective walking distance and duration. The authors determined the test-retest reliability across three measurements (intraclass correlation coefficient [ICC], standard error of measurement [SEM], and mean 6WD [95% CI]) stratified for age and sex, and content validity (linear regression coefficients) between 6WD and PROMs.RESULTS The ICC for repeated app-based 6WD measurements was 0.89 (95% CI 0.87-0.91, p < 0.001) and the SEM was 34 meters. The overall mean 6WD was 585.9 meters (95% CI 574.7-597.0 meters), with significant differences across age categories (p < 0.001). The 6WD was on average about 32 meters less in females (570.5 vs 602.2 meters, p = 0.005). There were linear correlations between average 6WD and VAS back pain, VAS leg pain, COMI Back and COMI subscores of pain intensity and disability, ZCQ symptom severity, ZCQ physical function, and ZCQ pain and neuroischemic symptoms subscores, as well as with subjective walking distance and duration, indicating that subjects with higher pain, higher disability, and lower subjective walking capacity had significantly lower 6WD (all p < 0.001).CONCLUSIONS This study provides normative data for app-based 6WD measurements in a multicenter sample from 8 institutions and 5 countries. These values can now be used as reference to compare 6WT results and quantify objective functional impairment in patients with degenerative diseases of the spine using z-scores. The authors found a good to excellent test-retest reliability of the 6WT app, a low area of uncertainty, and high content validity of the average 6WD with commonly used PROMs. Show less
Background Structural brain MRI measures are frequently examined in both healthy and clinical groups, so an understanding of how these measures vary over time is desirable.Purpose To test the... Show moreBackground Structural brain MRI measures are frequently examined in both healthy and clinical groups, so an understanding of how these measures vary over time is desirable.Purpose To test the stability of structural brain MRI measures over time.Population In all, 112 healthy volunteers across four sites.Study Type Retrospective analysis of prospectively acquired data.Field Strength/Sequence 3 T, magnetization prepared - rapid gradient echo, and single-shell diffusion sequence.Assessment Diffusion, cortical thickness, and volume data from the sensorimotor network were assessed for stability over time across 3 years. Two sites used a Siemens MRI scanner, two sites a Philips scanner.Statistical Tests The stability of structural measures across timepoints was assessed using intraclass correlation coefficients (ICC) for absolute agreement, cutoff >= 0.80, indicating high reliability. Mixed-factorial analysis of variance (ANOVA) was used to examine between-site and between-scanner type differences in individuals over time.Results All cortical thickness and gray matter volume measures in the sensorimotor network, plus all diffusivity measures (fractional anisotropy plus mean, axial and radial diffusivities) for primary and premotor cortices, primary somatosensory thalamic connections, and the cortico-spinal tract met ICC. The majority of measures differed significantly between scanners, with a trend for sites using Siemens scanners to produce larger values for connectivity, cortical thickness, and volume measures than sites using Phillips scanners.Data Conclusion Levels of reliability over time for all tested structural MRI measures were generally high, indicating that any differences between measurements over time likely reflect underlying biological differences rather than inherent methodological variability.Level of Evidence 4.Technical Efficacy Stage 1. Show less
Introduction Accurate assessment of joint health in persons with haemophilia is crucial. Several haemophilia-specific measurement tools are available, but an overview of the measurement properties... Show moreIntroduction Accurate assessment of joint health in persons with haemophilia is crucial. Several haemophilia-specific measurement tools are available, but an overview of the measurement properties is lacking. Aim To provide an overview of the measurement properties of haemophilia-specific measurement tools to assess clinical joint health. Methods MEDLINE and EMBASE were searched for reports on reliability, validity or responsiveness of the World Federation of Haemophilia Orthopedic Joint Score (WFH), Colorado Physical Examination Score (CPE), joint examination score by Petrini (PJS) and Hemophilia Joint Health Score (HJHS). Methodological quality of the studies was assessed using an adapted COSMIN checklist. Results The search yielded 2905 unique hits, and 98 papers were included. The methodological quality of the included studies was limited. The HJHS was studied most extensively, which yielded limited evidence for good internal consistency and structural validity, moderate evidence for hypothesis testing in adults and conflicting evidence for hypothesis testing in children. Reliability, measurement error and responsiveness were rated unknown due to low COSMIN scores. For the CPE and PJS, we found limited to moderate evidence for good responsiveness and conflicting evidence for hypothesis testing. Conclusion Only patchy evidence is available on the quality of measurement properties of all haemophilia-specific joint health scores. Although significant gaps in the evidence for all instruments remain, measurement properties of the HJHS were most extensively studied and show no drawbacks for use in clinical practice. This review forms the basis for further research aimed at the assessment of measurement properties of measurement tools to assess joint health. Show less
Introduction: Standardized assessments are widely used by speech pathologists in clinical and research settings to evaluate the language abilities of school-aged children and inform decisions about... Show moreIntroduction: Standardized assessments are widely used by speech pathologists in clinical and research settings to evaluate the language abilities of school-aged children and inform decisions about diagnosis, eligibility for services and intervention. Given the significance of these decisions, it is important that assessments have sound psychometric properties.Objective: The aim of this systematic review was to examine the psychometric quality of currently available comprehensive language assessments for school-aged children and identify assessments with the best evidence for use.Methods: Using the PRISMA framework as a guideline, a search of five databases and a review of websites and textbooks was undertaken to identify language assessments and published material on the reliability and validity of these assessments. The methodological quality of selected studies was evaluated using the COSMIN taxonomy and checklist.Results: Fifteen assessments were evaluated. For most assessments evidence of hypothesis testing (convergent and discriminant validity) was identified; with a smaller number of assessments having some evidence of reliability and content validity. No assessments presented with evidence of structural validity, internal consistency or error measurement. Overall, all assessments were identified as having limitations with regards to evidence of psychometric quality.Conclusions: Further research is required to provide good evidence of psychometric quality for currently available language assessments. Of the assessments evaluated, the Assessment of Literacy and Language, the Clinical Evaluation of Language Fundamentals-5th Edition, the Clinical Evaluation of Language Fundamentals-Preschool: 2nd Edition and the Preschool Language Scales-5th Edition presented with most evidence and are thus recommended for use. Show less
Galen, K.P.M. van; Timmer, M.A.; Kleijn, P. de; Fischer, K.; Foppen, W.; Schutgens, R.E.G.; ... ; Win Study Grp 2017