BACKGROUND. Dose reduction strategies for coronary CTA (CCTA) have been underused in clinical practice given concern that the strategies may lower image quality.OBJECTIVE. The purpose of this study... Show moreBACKGROUND. Dose reduction strategies for coronary CTA (CCTA) have been underused in clinical practice given concern that the strategies may lower image quality.OBJECTIVE. The purpose of this study was to explore associations between dose reduction strategies and CCTA image quality in real-world clinical practice.METHODS. This subanalysis of the international Prospective Multicenter Registry on Radiation Dose Estimates of Cardiac CT Angiography in Daily Practice in 2017 (PROTECTION VI) study included 3725 patients (2109 men, 1616 women; median age, 59 years) who underwent CCTA for coronary artery evaluation performed at 55 sites in 32 countries. CCTA image sets were reviewed at a core laboratory. A range of patient and scan characteristics, including use of three dose reduction strategies (prospective ECG triggering, low tube potential, and iterative image reconstruction) and image dose, were recorded. A single core laboratory member reviewed all examinations for quantitative image quality measures, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and reviewed 50% of examinations to assign a qualitative CCTA image quality score and a semiquantitative coronary calcification measure. Multivariable logistic regression models were used to identify predictors of image quality. A second core laboratory member repeated quantitative measures for 100 examinations and the qualitative measure for 383 (approximately 20%) examinations to assess interreader agreement.RESULTS. Independent predictors (p < .05) of SNR were female sex (effect size, 2.70), lower body mass index (0.38 per 1-unit decrease), stable sinus rhythm (1.71), and scanner manufacturer (variable effect across manufacturers). These factors were also the only independent predictors of CNR. Independent predictors (p < .05) of CCTA image quality were heart rate (0.17 per 10 beats/min reduction) and coronary calcification (0.15 per coronary calcification grade). None of the three dose-saving strategies or dose-length product was an independent predictor of any image quality measure. Interreader agreement analysis showed intraclass correlation coefficients of 0.874 for SNR and 0.891 for CNR and a kappa value of 0.812 for the qualitative score.CONCLUSION. This large international multicenter study shows that three dose reduction strategies were not associated with decreased CCTA image quality.CLINICAL IMPACT. The dose reduction strategies should be routinely implemented in clinical CCTA. Show less
Stocker, T.J.; Leipsic, J.; Hadamitzky, M.; Chen, M.Y.; Rubinshtein, R.; Deseive, S.; ... ; Hausleiter, J. 2020
OBJECTIVES The aim of this study was to assess the use of low tube potentials for coronary computed tomography angiography (CCTA) in worldwide clinical practice and its influence on radiation... Show moreOBJECTIVES The aim of this study was to assess the use of low tube potentials for coronary computed tomography angiography (CCTA) in worldwide clinical practice and its influence on radiation exposure, contrast agent volume, and image quality.BACKGROUND CCTA is frequently used in clinical practice. Lowering of tube potential is a potent method to reduce radiation exposure and to economize contrast agent volume.METHODS CCTAs of 4,006 patients from 61 international study sites were analyzed regarding very-tow (<= 80 kVp), tow (90 to100 kVp), conventional (110 to 120 kVp), and high (>= 130 kVp) tube potentials. The impact on dose-length product (DLP) and contrast agent volume was analyzed. Image quality was determined by evaluation of the diagnostic applicability and assessment of the objective image parameters signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR).RESULTS When compared with conventional tube potentials, low tube potentials were used in 56% of CCTAs (<= 80 kVp 9%; 90 to 100 kVp: 47%), which varied among sites from 0% to 100%. Tube potential reduction was associated with low-cardiovascular risk profile, low body mass index (BMI), and new-generation scanners. Median radiation exposure was lowered by 68% or 50% and median contrast agent volume by 25% or 13% for tube potential protocols of <= 80 kVp or 90 to 100 kVp when compared with conventional tube potentials, respectively (all p < 0.001). With the use of lower tube potentials, the frequency of diagnostic scans was maintained (p = 0.41), whereas SNR and CNR significantly improved (both p < 0.001). Considering BMI eligibility criteria, 58% (n = 946) of conventionally scanned patients would have been suitable for low tube potential protocols, and 44% (n = 831) of patients scanned with 90 to 100 kVp would have been eligible for very-low tube potential CCTA imaging of <= 80 kVp.CONCLUSIONS This large international registry confirms the feasibility of tube potential reduction in clinical practice leading to rower radiation exposure and lower contrast volumes. The current registry also demonstrates that this strategy is stilt underused in daily practice. (C) 2020 by the American College of Cardiology Foundation. Show less
Kok, J.L.; Teepen, J.C.; Leeuwen, F.E. van; Tissing, W.J.E.; Neggers, S.J.C.M.M.; Pal, H.J. van der; ... ; DCOG-LATER Study Group 2019