BACKGROUND. Dose reduction strategies for coronary CTA (CCTA) have been underused in clinical practice given concern that the strategies may lower image quality.OBJECTIVE. The purpose of this study... Show moreBACKGROUND. Dose reduction strategies for coronary CTA (CCTA) have been underused in clinical practice given concern that the strategies may lower image quality.OBJECTIVE. The purpose of this study was to explore associations between dose reduction strategies and CCTA image quality in real-world clinical practice.METHODS. This subanalysis of the international Prospective Multicenter Registry on Radiation Dose Estimates of Cardiac CT Angiography in Daily Practice in 2017 (PROTECTION VI) study included 3725 patients (2109 men, 1616 women; median age, 59 years) who underwent CCTA for coronary artery evaluation performed at 55 sites in 32 countries. CCTA image sets were reviewed at a core laboratory. A range of patient and scan characteristics, including use of three dose reduction strategies (prospective ECG triggering, low tube potential, and iterative image reconstruction) and image dose, were recorded. A single core laboratory member reviewed all examinations for quantitative image quality measures, including signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and reviewed 50% of examinations to assign a qualitative CCTA image quality score and a semiquantitative coronary calcification measure. Multivariable logistic regression models were used to identify predictors of image quality. A second core laboratory member repeated quantitative measures for 100 examinations and the qualitative measure for 383 (approximately 20%) examinations to assess interreader agreement.RESULTS. Independent predictors (p < .05) of SNR were female sex (effect size, 2.70), lower body mass index (0.38 per 1-unit decrease), stable sinus rhythm (1.71), and scanner manufacturer (variable effect across manufacturers). These factors were also the only independent predictors of CNR. Independent predictors (p < .05) of CCTA image quality were heart rate (0.17 per 10 beats/min reduction) and coronary calcification (0.15 per coronary calcification grade). None of the three dose-saving strategies or dose-length product was an independent predictor of any image quality measure. Interreader agreement analysis showed intraclass correlation coefficients of 0.874 for SNR and 0.891 for CNR and a kappa value of 0.812 for the qualitative score.CONCLUSION. This large international multicenter study shows that three dose reduction strategies were not associated with decreased CCTA image quality.CLINICAL IMPACT. The dose reduction strategies should be routinely implemented in clinical CCTA. Show less
PurposeTo study the feasibility of a channelized Hotelling observer (CHO) to predict human observer performance in detecting calcification-like signals in mammography images of an anthropomorphic... Show morePurposeTo study the feasibility of a channelized Hotelling observer (CHO) to predict human observer performance in detecting calcification-like signals in mammography images of an anthropomorphic breast phantom, as part of a quality control (QC) framework.MethodsA prototype anthropomorphic breast phantom with inserted gold disks of 0.25 mm diameter was imaged with two different digital mammography x-ray systems at four different dose levels. Regions of interest (ROIs) were extracted from the acquired processed and unprocessed images, signal-present and signal-absent. The ROIs were evaluated by a CHO using four different formulations of the difference of Gaussian (DoG) channel sets. Three human observers scored the ROIs in a two-alternative forced-choice experiment. We compared the human and the CHO performance on the simple task to detect calcification-like disks in ROIs with and without postprocessing. The proportion of correct responses of the human reader (PCH) and the CHO (PCCHO) was calculated and the correlation between the two was analyzed using a mixed-effect regression model. To address the signal location uncertainty, the impact of shifting the DoG channel sets in all directions up to two pixels was evaluated. Correlation results including the goodness of fit (r(2)) of PCH and PCCHO for all different parameters were evaluated.ResultsSubanalysis by system yielded strong correlations between PCH and PCCHO, with r(2) between PCH and PCCHO was found to be between 0.926 and 0.958 for the unshifted and between 0.759 and 0.938 for the shifted channel sets, respectively. However, the linear fit suggested a slight system dependence. PCCHO with shifted channel sets increased CHO performance but the correlation with humans was decreased. These correlations were not considerably affected by of the DoG channel set used.ConclusionsThere is potential for the CHO to be used in QC for the evaluation of detectability of calcification-like signals. The CHO can predict the PC of humans in images of calcification-like signals of two different systems. However, a global model to be used for all systems requires further investigation. Show less
Ba, A.; Abbey, C.K.; Baek, J.; Han, M.; Bouwman, R.W.; Balta, C.; ... ; Bochud, F.O. 2018