Objective: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to... Show moreObjective: Conventionally, ocular proton therapy (PT) is planned using measurements obtained by an ophthalmologist using ultrasound, fundoscopy, biometry, and intraoperative assessments. Owing to the recent advances in magnetic resonance imaging (MRI) of uveal melanoma (UM), it is possible to acquire high-resolution 3-dimensional images of the eye, providing the opportunity to incorporate MRI in ocular PT planning. In this study, we described how these measurements can be obtained using MRI, compared the MRI-based measurements with conventional ophthalmic measurements, and identified potential pitfalls for both modalities. Design: Cross-sectional study. Subjects: Data from 23 consecutive patients with UM treated with PT were retrospectively evaluated. Methods: Magnetic resonance imaging-based measurements of axial length, tumor height and basal diameter, and marker-tumor distances were compared with the conventional ophthalmic measurements, and discrepancies were evaluated in a multidisciplinary setting. Main Outcome Measures: Tumor prominence and basal diameters on MRI and ultrasound, axial length on MRI and biometry, tumor-marker distances on MRI and measured intraoperatively. Results: The mean absolute differences of the tumor height and basal diameter measurements between ultrasound and MRI were 0.57 mm and 1.44 mm, respectively. Larger absolute differences in height and basal diameter were observed when the full tumor extent was not visible on ultrasound (0.92 mm and 1.67 mm, respectively) compared with when the full tumor extent was visible (0.44 mm and 1.15 mm, respectively). When the full tumor was not visible on ultrasound, MRI was considered more reliable. Tumor-marker distances measured using MRI and intraoperative techniques differed < 1 mm in 55% of the markers. For anteriorly located and mushroom-shaped tumors (25% of the markers), MRI provided more accurate measurements. In flat UM (15% of the markers), however, it was difficult to delineate the tumor on MRI. The mean absolute difference in axial length between optical biometry and MRI was 0.50 mm. The presence of the tumor was found to influence optical biometry in 15 of 22 patients; the remaining patients showed a better agreement (0.30 mm). Magnetic resonance imaging-based biometry was considered more reliable in patients with UM. Conclusions: Magnetic resonance imaging allowed for the 3-dimensional assessment of the tumor and surrounding tissue. In specific patients, it provided a more reliable measurement of axial length, tumor dimensions, and marker-tumor distances and could contribute to a more accurate treatment planning. Never-theless, a combined evaluation remains advised, especially for flat UM. Show less
Background and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension... Show moreBackground and Purpose: Three-dimensional (3D) Magnetic Resonance Imaging (MRI) is increasingly used to complement conventional two-dimensional ultrasound in the assessment of tumour dimension measurement of uveal melanoma. However, the lack of definitions of the 3D measurements of these tumour dimensions hinders further adaptation of MRI in ocular radiotherapy planning. In this study, we composed 3D MR-based definitions of tumour prominence and basal diameter and compared them to conventional ultrasound. Materials and methods: Tumours were delineated on 3DT2 and contrast-enhanced 3DT1 (T1gd) MRI for 25 pa-tients. 3D definitions of tumour prominence and diameter were composed and evaluated automatically on the T1gd and T2 contours. Automatic T1gd measurements were compared to manual MRI measurements, to auto-matic T2 measurements and to manual ultrasound measurements. Results: Prominence measurements were similar for all modalities (median absolute difference 0.3 mm). Auto-matic T1gd diameter measurements were generally larger than manual MRI, automatic T2 and manual ultra-sound measurements (median absolute differences of 0.5, 1.6 and 1.1 mm respectively), mainly due to difficulty defining the axis of the largest diameter. Largest differences between ultrasound and MRI for both prominence and diameter were found in anteriorly located tumours (up to 1.6 and 4.5 mm respectively), for which the tumour extent could not entirely be visualized with ultrasound. Conclusions: The proposed 3D definitions for tumour prominence and diameter agreed well with ultrasound measurements for tumours for which the extent was visible on ultrasound. 3D MRI measurements generally provided larger diameter measurements than ultrasound. In anteriorly located tumours, the MRI measurements were considered more accurate than conventional ultrasound. Show less
Berg, R. van den; Ohrndorf, S.; Kortekaas, M.C.; Helm-van Mil, A.H.M. van der 2018
Atherosclerotic changes of the carotid artery are associated with elevated cardiovascular risk. Non-invasive imaging studies of the artery can provide information on the presence or absence of... Show moreAtherosclerotic changes of the carotid artery are associated with elevated cardiovascular risk. Non-invasive imaging studies of the artery can provide information on the presence or absence of abnormalities. Although the techniques are extensively used in clinical research their implementation in common practice is not widespread. In this thesis the potential benefits and challenges of carotid imaging in clinical practice are studied. Ultrasound and magnetic resonance imaging are the two modalities of interest. The findings suggest that ultrasound can be performed by the clinician in a routine outpatient setting. Clinicians are able to detect atherosclerotic plaques but not intima-media thickness. Plaques are highly prevalent in asymptomatic primary prevention patients. Magnetic resonance imaging is a new highly reproducible modality but requires further clinical validation. Its utility in individual patient risk assessment is unclear and ultrasound validity cannot be extrapolated to magnetic resonance. The use of a combination of the two imaging modalities may allow for estimation of the lamina adventitia in vivo. Finally, interpretation of the imaging parameters must be done in conjunction with all cardiovascular risk factors and treatment decision should not be based on imaging results alone. Show less
This thesis focuses on epidemiological studies of hand OA in secondary care, erosive OA as a subset of hand OA and the added value of imaging in hand OA to understand better the pathophysiology of... Show moreThis thesis focuses on epidemiological studies of hand OA in secondary care, erosive OA as a subset of hand OA and the added value of imaging in hand OA to understand better the pathophysiology of hand OA and seek for opportunities to define progression in an earlier stage. Chapter 2 gives an overview about the current knowledge on hand OA and it is clear that hand OA is a prevalent, heterogeneous disorder (including several hand OA subsets) that can cause considerable pain and disability. Much less is known about the risk factors of progression in hand OA. Moderate evidence for an abnormal scintigram at baseline was found as a risk factor for radiographic progression in a systematic review as described in chapter 3. In rheumatology practice, the most prevalent phenotype of OA is hand OA as depicted in chapter 4. This symptomatic population experience a substantial lower health-related quality of life compared to the general population. The collaborations with the Rotterdam Study and NorStOP Study (chapter 5, 6, 7) revealed that 2.8% of the general population rising to 10.2% in the symptomatic population is affected by erosive disease in the interphalangeal joints (IPJs). Furthermore, erosions are not present in IPJs only and prevalence of erosive disease in 1st carpometacarpal joints (CMCJs) is also given. Persons with erosive OA in the interphalangeal joints report more pain and functional limitations, however to a lesser extent than persons with other rheumatic inflammatory diseases. Inflammation does play a role in OA joints with erosions, as assessed with Power Doppler Signal, greyscale synovitis and effusion on ultrasound (chapter 8). Also in OA joints without erosions, inflammatory signs are visible on ultrasound (chapter 9). Regarding other imaging modalities used in hand OA research, quantitative joint space width (JSW) measurements in hand OA joints have been shown to be associated with self-reported pain, functional ability and structural abnormalities (chapter 10), whereas features on Magnetic Resonance Imaging (MRI, such as abnormal collateral ligaments and bone marrow lesions) are also associated with pain upon palpation in individual joints (chapter 11). Finally, the health-related quality of life in hand OA patients in rheumatology practice can be improved with a protocol-led consultation about increasing the use of helping aids and acetaminophen given by a clinical nurse specialist (chapter 12). Show less
We have developed several methods for automated analysis of echocardiographic images. This thesis describes these methods and their evaluation and use. It is shown that semiautomatic detection... Show moreWe have developed several methods for automated analysis of echocardiographic images. This thesis describes these methods and their evaluation and use. It is shown that semiautomatic detection based on Dynamic Programming and Pattern Matching provides a useful and reliable way of analyzing 2D echocardiographic sequences of different cross sections. Main conclusion is that the new detection tools based on statistical models (Active Appearance Models) provide superior possibilities for automated analysis of echocardiographic images, since they are capable of realistically modeling both the typical problems and artifacts of cardiac ultrasound and the variability between patients. Also, these tools can be extended towards multi-view and multi-stage applications (e.g. stress echo), higher dimensions (3D echo), and simultaneous detection of multiple structures (LV, RV, atria, epicardium, valves). They also offer possibilities for computer-aided diagnosis, such as wall motion abnormality classification (stress echo and Cardiac Resynchronization Therapy). Further development and integration with other border detection and tracking approaches is certainly feasible and will offer a range of new research opportunities. The difficulties have not yet been completely overcome, but we are confident that fully automated, reliable analysis of echocardiographic images will eventually become a definite reality. Show less
This thesis describes aspects of the epidemiology and attempts to control infection and pathology due to the nematode parasite Oesophagostomum bifurcum . In northern Ghana and Togo O. bifurcum is... Show moreThis thesis describes aspects of the epidemiology and attempts to control infection and pathology due to the nematode parasite Oesophagostomum bifurcum . In northern Ghana and Togo O. bifurcum is an important parasite of humans; elsewhere it is predominantly seen as a parasite of non-human primates. It is shown that frequency and severity of colonic pathology, measured by ultrasound, is associated with the intensity of infection as measured with coproculture. Females are more infected than males but convincing explanations for the gender-dependent difference of infection rates are not found. Details of the route of transmission remain obscure. Mass treatment with Albendazole resulted in a very important reduction of both prevalence and morbidity of infection. Elimination of human oesophagostomiasis is within reach. The impact on hookworms, also effectively killed by the drug, is considerably smaller. Interruption of Albendazole treatment results of rapidly increasing infection rates in hookworm but not in Oesophagostomum. Integration of control activities in the filariasis elimination programme is likely to result in elimination of human oesophagostomiasis but not of human hookworm infection. Show less
Venous thrombosis is a well-known complication of central vein catheters (CVCs), which may cause serious morbidity and may result in potentially lethal complications such as pulmonary embolism. In... Show moreVenous thrombosis is a well-known complication of central vein catheters (CVCs), which may cause serious morbidity and may result in potentially lethal complications such as pulmonary embolism. In this thesis the general risk of CVC related thrombosis has been assessed, i.e., what is the overall risk of developing CVC related thrombosis? Which patients are prone to develop thrombosis with its associated morbidity? Are we able to predict this risk by routine surveillance in "high-risk" patients? Better knowledge of the incidence of CVC related thrombosis and identification of high-risk groups will assist clinicians in decision making about CVC use in the various patient-groups and in whom anticoagulant prophylaxis may be warranted. In summary, the a priori determination of common inherited and acquired risk factors may form a basis to guide (prophylactic) treatment decisions. Vulnerable patients may benefit the most, i.e. those who have a high risk of clinically manifest thrombosis, and who are at risk of hemorrhage, such as patients who undergo intensive chemotherapy. Besides, surveillance of these patients with screening by ultrasound, or alternatively surveillances cultures, may be useful to identify patients at high or low risk for clinically manifest CVC related thrombosis, and focused early intervention may be initiated. Show less