Purpose Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore... Show morePurpose Prostate-specific membrane antigen (PSMA) is increasingly considered as a molecular target to achieve precision surgery for prostate cancer. A Delphi consensus was conducted to explore expert views in this emerging field and to identify knowledge and evidence gaps as well as unmet research needs that may help change practice and improve oncological outcomes for patients.Methods One hundred and five statements (scored by a 9-point Likert scale) were distributed through SurveyMonkey (R). Following evaluation, a consecutive second round was performed to evaluate consensus (16 statements; 89% response rate). Consensus was defined using the disagreement index, assessed by the research and development project/University of California, Los Angeles appropriateness method.Results Eighty-six panel participants (72.1% clinician, 8.1% industry, 15.1% scientists, and 4.7% other) participated, most with a urological background (57.0%), followed by nuclear medicine (22.1%). Consensus was obtained on the following: (1) The diagnostic PSMA-ligand PET/CT should ideally be taken < 1 month before surgery, 1-3 months is acceptable; (2) a 16-20-h interval between injection of the tracer and surgery seems to be preferred; (3) PSMA targeting is most valuable for identification of nodal metastases; (4) gamma, fluorescence, and hybrid imaging are the preferred guidance technologies; and (5) randomized controlled clinical trials are required to define oncological value. Regarding surgical margin assessment, the view on the value of PSMA-targeted surgery was neutral or inconclusive. A high rate of "cannot answer" responses indicates further study is necessary to address knowledge gaps (e.g., Cerenkov or beta-emissions).Conclusions This Delphi consensus provides guidance for clinicians and researchers that implement or develop PSMA-targeted surgery technologies. Ultimately, however, the consensus should be backed by randomized clinical trial data before it may be implemented within the guidelines. Show less
Background: It has been proven that intraoperative prostate-specific membrane antigen (PSMA)-targeted radioguidance is valuable for the detection of prostate cancer (PCa) lesions during open... Show moreBackground: It has been proven that intraoperative prostate-specific membrane antigen (PSMA)-targeted radioguidance is valuable for the detection of prostate cancer (PCa) lesions during open surgery. Rapid extension of robot-assisted, minimally invasive surgery has increased the need to make PSMA-radioguided surgery (RGS) robot-compliant.Objective: To evaluate whether the miniaturized DROP-IN gamma probe facilitates translation of PSMA-RGS to robotic surgery in men with recurrent PCa.Design, setting, and participants: This prospective feasibility study included 20 patients with up to three pelvic PCa recurrences (nodal or local) on staging PSMA positron emission tomography (PET) after previous curative-intent therapy.Surgical procedure: Robot-assisted PSMA-RGS using the DROP-IN gamma probe was carried out 19-23 h after intravenous injection of (99m)technetium PSMA-Investigation & Surgery (Tc-99m-PSMA-I&S).Measurements: The primary endpoint was the feasibility of robot-assisted PSMA-RGS. Secondary endpoints were a comparison of the radioactive status (positive or negative) of resected specimens and final histopathology results, prostate-specific antigen (PSA) response following PSMA-RGS, and complications according to the Clavien-Dindo classification.Results and limitations: Using the DROP-IN probe, 19/21 (90%) PSMA-avid lesions could be resected robotically. On a per-lesion basis, the sensitivity and specificity of robot-assisted PSMA-RGS was 86% and 100%, respectively. A prostate-specific antigen (PSA) reduction of >50% and a complete biochemical response (PSA <0.2 ng/ml) were seen in 12/18 (67%) and 4/18 (22%) patients, respectively. During follow-up of up to 15 mo,* Corresponding author. Department of Urology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, Amsterdam 1066 CX, The Netherlands. Tel. +31 205126988. E-mail address: h.d.barros@nki.nl (H.A. de Barros) Show less
Background: With the rise of prostate-specific membrane antigen (PSMA) radioguided surgery, which is performed using a microdosing regime, demand for visual target confirmation via fluorescence... Show moreBackground: With the rise of prostate-specific membrane antigen (PSMA) radioguided surgery, which is performed using a microdosing regime, demand for visual target confirmation via fluorescence guidance is growing. While proven very effective for radiotracers, microdosing approaches the detection limit for fluorescence imaging. Thus, utility will be highly dependent on the tracer performance, the sensitivity of the fluorescence camera used, and the degree of background signal. Using a porcine model the ability to perform robot-assisted radical prostatectomy under fluorescence guidance using the bimodal or rather hybrid PSMA tracer (Tc-99m-EuK-(SO3)Cy5-mas(3)) was studied, while employing the tracer in a microdosing regime. This was followed by ex vivo evaluation in surgical specimens obtained from prostate cancer patients. Results: T-50% blood and T-50% urine were reached at 85 min and 390 min, in, respectively, blood and urine. Surgical fluorescence imaging allowed visualization of the prostate gland based on the basal PSMA-expression in porcine prostate. Together, in vivo visualization of the prostate and urinary excretion suggests at least an interval of > 7 h between tracer administration and surgery. Confocal microscopy of excised tissues confirmed tracer uptake in kidney and prostate, which was confirmed with PSMA IHC. No fluorescence was detected in other excised tissues. Tumor identification based on ex vivo fluorescence imaging of human prostate cancer specimens correlated with PSMA IHC. Conclusion: Intraoperative PSMA-mediated fluorescence imaging with a microdosing approach was shown to be feasible. Furthermore, EuK-(SO3)Cy5-mas(3) allowed tumor identification in human prostate samples, underlining the translational potential of this novel tracer. Trial registration Approval for use of biological material for research purposes was provided by the Translational Research Board of the Netherlands Cancer Institute-Antoni van Leeuwenhoek hospital (NKI-AvL) under reference IRBm19-273 (22/10/2019). Show less
Background: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the... Show moreBackground: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the DROP-IN promotes the implementation of radioguided surgery in the robotic setting.Objective: To confirm the utility and safety profile of the DROP-IN gamma probe and to perform a comparison with the traditional laparoscopic gamma probe and fluorescence guidance.Design, setting, and participants: Twenty-five prostate cancer patients were scheduled for a robot-assisted sentinel lymph node (SN) procedure, extended pelvic lymph node dissection, and prostatectomy at a single European centre.Surgical procedure: After intraprostatic injection of indocyanine green (ICG)-Tc-99m-nanocolloid (n = 12) or Tc-99m-nanocolloid + ICG (n = 13), SN locations were defined using preoperative imaging. Surgical excision of SNs was performed under image guidance using the DROP-IN gamma probe, the traditional laparoscopic gamma probe, and fluorescence imaging.Measurements: Intraoperative SN detection was assessed for the different modalities and related to anatomical locations. Patient follow-up was included (a median of 18 mo).Results and limitations: Overall, 47 SNs were pursued in vivo by the DROP-IN gamma probe, of which 100% were identified. No adverse events related to its use were observed. In vivo fluorescence imaging identified 91% of these SNs. The laparoscopic gamma probe identified only 76% of these SNs, where the detection inaccuracies appeared to be related to specific anatomical regions.Conclusions: Owing to improved manoeuvrability, the DROP-IN probe yielded improved SN detection rates compared with the traditional gamma probe and fluorescence imaging. These findings underline that the DROP-IN technology provides a valuable tool for radioguided surgery in the robotic setting.Patient summary: Radioguided robot-assisted surgery with the novel DROP-IN gamma probe is feasible and safe. It enables more efficient intraoperative identification of sentinel lymph nodes than can be achieved with a traditional laparoscopic gamma probe. The use of the DROP-IN probe in combination with fluorescence imaging allows for a complementary optical confirmation of node localisations. (C) 2020 The Author(s). Published by Elsevier B.V. on behalf of European Association of Urology. Show less