Introduction Previous studies indicated that location and amount of detected sentinel lymph nodes (SLNs) in prostate cancer (PCa) are influenced where SLN-tracer is deposited within the prostate.... Show moreIntroduction Previous studies indicated that location and amount of detected sentinel lymph nodes (SLNs) in prostate cancer (PCa) are influenced where SLN-tracer is deposited within the prostate. To validate whether intratumoral (IT) tracer injection helps to increase identification of tumor-positive lymph nodes (LNs) better than intraprostatic (IP) tracer injection, a prospective randomized phase II trial was performed.Methods PCa patients with a > 5% risk of lymphatic involvement were randomized between ultrasound-guided transrectal injection of indocyanine green-[Tc-99m]Tc-nanocolloid in 2 depots of 1 mL in the tumor (n = 55, IT-group) or in 4 depots of 0.5 mL in the peripheral zone of the prostate (n = 58, IP-group). Preoperative lymphoscintigraphy and SPECT/CT were used to define the location of the SLNs. SLNs were dissected using combination of radio- and fluorescence-guidance, followed by extended pelvic LN dissection and robot-assisted radical prostatectomy. Outcome measurements were number of tumor-bearing SNs, tumor-bearing LNs, removed nodes, number of patients with nodal metastases, and metastasis-free survival (MFS) of 4-7-year follow-up data.Results IT-injection did not result in significant difference of removed SLNs (5.0 vs 6.0, p = 0.317) and histologically positive SLNs (28 vs 22, p = 0.571). However, in IT-group, the SLN-positive nodes were 73.7% of total positive nodes compared to 37.3% in IP-group (p = 0.015). Moreover, significantly more node-positive patients were found in IT-group (42% vs 24%, p = 0.045), which did not result in worse MFS. In two patients (3.6%) from whom the IT-tracer injection only partly covered intraprostatic tumor spread, nodal metastases in ePLND without tumor-positive SNs were yielded.Conclusions The percentage-positive SLNs found after IT-injection were significantly higher compared to IP-injection. Significantly more node-positive patients were found using IT-injection, which did not affect MFS. IT-injection failed to detect nodal metastases from non-index satellite lesions. Therefore, we suggest to combine IT- and IP-tracer injections in men with visible tumor on imaging. Show less
Background: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the... Show moreBackground: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the DROP-IN promotes the implementation of radioguided surgery in the robotic setting.Objective: To confirm the utility and safety profile of the DROP-IN gamma probe and to perform a comparison with the traditional laparoscopic gamma probe and fluorescence guidance.Design, setting, and participants: Twenty-five prostate cancer patients were scheduled for a robot-assisted sentinel lymph node (SN) procedure, extended pelvic lymph node dissection, and prostatectomy at a single European centre.Surgical procedure: After intraprostatic injection of indocyanine green (ICG)-Tc-99m-nanocolloid (n = 12) or Tc-99m-nanocolloid + ICG (n = 13), SN locations were defined using preoperative imaging. Surgical excision of SNs was performed under image guidance using the DROP-IN gamma probe, the traditional laparoscopic gamma probe, and fluorescence imaging.Measurements: Intraoperative SN detection was assessed for the different modalities and related to anatomical locations. Patient follow-up was included (a median of 18 mo).Results and limitations: Overall, 47 SNs were pursued in vivo by the DROP-IN gamma probe, of which 100% were identified. No adverse events related to its use were observed. In vivo fluorescence imaging identified 91% of these SNs. The laparoscopic gamma probe identified only 76% of these SNs, where the detection inaccuracies appeared to be related to specific anatomical regions.Conclusions: Owing to improved manoeuvrability, the DROP-IN probe yielded improved SN detection rates compared with the traditional gamma probe and fluorescence imaging. These findings underline that the DROP-IN technology provides a valuable tool for radioguided surgery in the robotic setting.Patient summary: Radioguided robot-assisted surgery with the novel DROP-IN gamma probe is feasible and safe. It enables more efficient intraoperative identification of sentinel lymph nodes than can be achieved with a traditional laparoscopic gamma probe. The use of the DROP-IN probe in combination with fluorescence imaging allows for a complementary optical confirmation of node localisations. (C) 2020 The Author(s). Published by Elsevier B.V. on behalf of European Association of Urology. Show less