Background Advances in four-dimensional fow cardiovascular magnetic resonance (4D fow CMR) have allowed quantifcation of left ventricular (LV) and right ventricular (RV) blood fow. We aimed to (1)... Show moreBackground Advances in four-dimensional fow cardiovascular magnetic resonance (4D fow CMR) have allowed quantifcation of left ventricular (LV) and right ventricular (RV) blood fow. We aimed to (1) investigate age and sex diferences of 4D fow CMR-derived LV and RV relative fow components and kinetic energy (KE) parameters indexed to end-diastolic volume (KEiEDV) in healthy subjects; and (2) assess the efects of age and sex on these parameters. Methods We performed 4D fow analysis in 163 healthy participants (42% female; mean age 43±13 years) of a pro‑ spective registry study (NCT03217240) who were free of cardiovascular diseases. Relative fow components (direct fow, retained infow, delayed ejection fow, residual volume) and multiple phasic KEiEDV (global, peak systolic, average systolic, average diastolic, peak E-wave, peak A-wave) for both LV and RV were analysed. Results Compared with men, women had lower median LV and RV residual volume, and LV peak and average systolic KEiEDV, and higher median values of RV direct fow, RV global KEiEDV, RV average diastolic KEiEDV, and RV peak E-wave KEiEDV. ANOVA analysis found there were no diferences in fow components, peak and average systolic, average diastolic and global KEiEDV for both LV and RV across age groups. Peak A-wave KEiEDV increased signifcantly (r=0.458 for LV and 0.341 for RV), whereas peak E-wave KEiEDV (r=− 0.355 for LV and − 0.318 for RV), and KEiEDV E/A ratio (r=− 0.475 for LV and − 0.504 for RV) decreased signifcantly, with age. Conclusion These data using state-of-the-art 4D fow CMR show that biventricular fow components and kinetic energy parameters vary signifcantly by age and sex. Age and sex trends should be considered in the interpretation of quantitative measures of biventricular fow. Show less
Background Cardiovascular magnetic resonance (CMR) offers comprehensive right ventricular (RV) evaluation in pulmonary arterial hypertension (PAH). Emerging four-dimensional (4D) flow CMR allows... Show moreBackground Cardiovascular magnetic resonance (CMR) offers comprehensive right ventricular (RV) evaluation in pulmonary arterial hypertension (PAH). Emerging four-dimensional (4D) flow CMR allows visualization and quantification of intracardiac flow components and calculation of phasic blood kinetic energy (KE) parameters but it is unknown whether these parameters are associated with cardiopulmonary exercise test (CPET)-assessed exercise capacity, which is a surrogate measure of survival in PAH. We compared 4D flow CMR parameters in PAH with healthy controls, and investigated the association of these parameters with RV remodelling, RV functional and CPET outcomes. Methods PAH patients and healthy controls from two centers were prospectively enrolled to undergo on-site cine and 4D flow CMR, and CPET within one week. RV remodelling index was calculated as the ratio of RV to left ventricular (LV) end-diastolic volumes (EDV). Phasic (peak systolic, average systolic, and peak E-wave) LV and RV blood flow KE indexed to EDV (KEIEDV) and ventricular LV and RV flow components (direct flow, retained inflow, delayed ejection flow, and residual volume) were calculated. Oxygen uptake (VO2), carbon dioxide production (VCO2) and minute ventilation (VE) were measured and recorded. Results 45 PAH patients (46 +/- 11 years; 7 M) and 51 healthy subjects (46 +/- 14 years; 17 M) with no significant differences in age and gender were analyzed. Compared with healthy controls, PAH had significantly lower median RV direct flow, RV delayed ejection flow, RV peak E-wave KEIEDV, peak VO2, and percentage (%) predicted peak VO2, while significantly higher median RV residual volume and VE/VCO2 slope. RV direct flow and RV residual volume were significantly associated with RV remodelling, function, peak VO2, % predicted peak VO2 and VE/VCO2 slope (all P < 0.01). Multiple linear regression analyses showed RV direct flow to be an independent marker of RV function, remodelling and exercise capacity. Conclusion In this 4D flow CMR and CPET study, RV direct flow provided incremental value over RVEF for discriminating adverse RV remodelling, impaired exercise capacity, and PAH with intermediate and high risk based on risk score. These data suggest that CMR with 4D flow CMR can provide comprehensive assessment of PAH severity, and may be used to monitor disease progression and therapeutic response. Show less
Demirkiran, A.; Geest, R.J. van der; Hopman, L.H.G.A.; Robbers, L.F.H.J.; Handoko, M.L.; Nijveldt, R.; ... ; Garg, P. 2022
Background: Myocardial infarction leads to complex changes in left ventricular (LV) hemodynamics. It remains unknown how four-dimensional acute changes in LV-cavity blood flow kinetic energy... Show moreBackground: Myocardial infarction leads to complex changes in left ventricular (LV) hemodynamics. It remains unknown how four-dimensional acute changes in LV-cavity blood flow kinetic energy affects LV-remodeling.Methods and results: In total, 69 revascularised ST-segment elevation myocardial infarction (STEMI) patients were enrolled. All patients underwent cardiovascular magnetic resonance (CMR) examination within 2 days of the index event and at 3-month. CMR examination included cine, late gadolinium enhancement, and whole-heart four-dimensional flow acquisitions. LV volume-function, infarct size (indexed to body surface area), microvas-cular obstruction, mitral inflow, and blood flow KEi (kinetic energy indexed to end-diastolic volume) charac-teristics were obtained. Adverse LV-remodeling was defined and categorized according to increase in LV end -diastolic volume of at least 10%, 15%, and 20%. Twenty-four patients (35%) developed at least 10%, 17 pa-tients (25%) at least 15%, 11 patients (16%) at least 20% LV-remodeling. Demographics and clinical history were comparable between patients with/without LV-remodeling. In univariable regression-analysis, A-wave KEi was associated with at least 10%, 15%, and 20% LV-remodeling (p = 0.03, p = 0.02, p = 0.02, respectively), whereas infarct size only with at least 10% LV-remodeling (p = 0.02). In multivariable regression-analysis, A-wave KEi was identified as an independent marker for at least 10%, 15%, and 20% LV-remodeling (p = 0.09, p < 0.01, p < 0.01, respectively), yet infarct size only for at least 10% LV-remodeling (p = 0.03).Conclusion: In patients with STEMI, LV hemodynamic assessment by LV blood flow kinetic energetics demon-strates a significant inverse association with adverse LV-remodeling. Late-diastolic LV blood flow kinetic ener-getics early after acute MI was independently associated with adverse LV-remodeling. Show less
Background: Left ventricular thrombus (LVT) formation is a frequent and serious complication of myocardial infarction (MI). How global LV flow characteristics are related to this phenomenon is yet... Show moreBackground: Left ventricular thrombus (LVT) formation is a frequent and serious complication of myocardial infarction (MI). How global LV flow characteristics are related to this phenomenon is yet uncertain. In this study, we investigated LV flow differences using 4D flow cardiovascular magnetic resonance (CMR) between chronic MI patients with LVT [MI-LVT(+)] and without LVT [MI-LVT(-)], and healthy controls. Methods: In this prospective cohort study, the 4D flow CMR data were acquired in 19 chronic MI patients (MI-LVT (+), n = 9 and MI-LVT(-), n = 10) and 9 age-matched controls. All included subjects were in sinus rhythm. The following LV flow parameters were obtained: LV flow components (direct, retained, delayed, residual), mean and peak kinetic energy (KE) values (indexed to instantaneous LV volume), mean and peak vorticity values, and diastolic vortex ring properties (position, orientation, shape). Results: The MI patients demonstrated a significantly larger amount of delayed and residual flow, and a smaller amount of direct flow compared to controls (p = 0.02, p = 0.03, and p < 0.001, respectively). The MI-LVT(+) patients demonstrated numerically increased residual flow and reduced retained and direct flow in comparison to MI-LVT(-) patients. Systolic mean and peak LV blood flow KE values were significantly lower in MI patients compared to controls (p = 0.04, p = 0.03, respectively). Overall, the mean and peak LV vorticity values were significantly lower in MI patients compared to controls. The mean and peak systolic vorticity at the basal level were significantly higher in MI-LVT(+) than in MI-LVT(-) patients (p < 0.01, for both). The vortex ring core during E-wave in MI-LVT(+) group was located in a less tilted orientation to the LV compared to MI-LVT(-) group (p < 0.01). Conclusions: Chronic MI patients with LVT express a different distribution of LV flow components, irregular vorticity vector fields, and altered diastolic vortex ring geometric properties as assessed by 4D flow CMR. Larger prospective studies are warranted to further evaluate the significance of these initial observations. Show less
Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it remains... Show moreFour-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it remains unclear whether 4D flow parameters can predict cardiopulmonary exercise testing (CPET) as a clinical outcome in repaired tetralogy of Fallot (rTOF). Current study aimed to (1) compare 4D flow CMR parameters in rTOF with age- and gender-matched healthy controls, (2) investigate associations of 4D flow parameters with functional and volumetric right ventricular (RV) remodelling markers, and CPET outcome. Show less
Background: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it... Show moreBackground: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) allows quantification of biventricular blood flow by flow components and kinetic energy (KE) analyses. However, it remains unclear whether 4D flow parameters can predict cardiopulmonary exercise testing (CPET) as a clinical outcome in repaired tetralogy of Fallot (rTOF). Current study aimed to (1) compare 4D flow CMR parameters in rTOF with age- and gender-matched healthy controls, (2) investigate associations of 4D flow parameters with functional and volumetric right ventricular (RV) remodelling markers, and CPET outcome.Methods: Sixty-three rTOF patients (14 paediatric, 49 adult; 30 +/- 15 years; 29 M) and 63 age- and gender-matched healthy controls (14 paediatric, 49 adult; 31 +/- 15 years) were prospectively recruited at four centers. All underwent cine and 4D flow CMR, and all adults performed standardized CPET same day or within one week of CMR. RV remodelling index was calculated as the ratio of RV to left ventricular (LV) end-diastolic volumes. Four flow components were analyzed: direct flow, retained inflow, delayed ejection flow and residual volume. Additionally, three phasic KE parameters normalized to end-diastolic volume (KEi(EDV)), were analyzed for both LV and RV: peak systolic, average systolic and peak E-wave.Results: In comparisons of rTOF vs. healthy controls, median LV retained inflow (18% vs. 16%, P = 0.005) and median peak E-wave KEi(EDV) (34.9 mu J/ml vs. 29.2 mu J/ml, P = 0.006) were higher in rTOF; median RV direct flow was lower in rTOF (25% vs. 35%, P < 0.001); median RV delayed ejection flow (21% vs. 17%, P < 0.001) and residual volume (39% vs. 31%, P < 0.001) were both greater in rTOF. RV KEi(EDV) parameters were all higher in rTOF than healthy controls (all P < 0.001). On multivariate analysis, RV direct flow was an independent predictor of RV function and CPET outcome. RV direct flow and RV peak E-wave KEi(EDV) were independent predictors of RV remodelling index.Conclusions: In this multi-scanner multicenter 4D flow CMR study, reduced RV direct flow was independently associated with RV dysfunction, remodelling and, to a lesser extent, exercise intolerance in rTOF patients. This supports its utility as an imaging parameter for monitoring disease progression and therapeutic response in rTOF. Show less
Background: Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) allows quantification of left ventricular (LV) blood flow. We aimed to 1) establish reference ranges for 4D flow... Show moreBackground: Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) allows quantification of left ventricular (LV) blood flow. We aimed to 1) establish reference ranges for 4D flow CMR-derived LV relative flow components and kinetic energy parameters indexed to end-diastolic volume (KEiEDV) among healthy Asian subjects, 2) assess effects of age and sex on these parameters, and 3) compare these parameters between Asian and Caucasian subjects.Methods: 74 healthy Asian subjects underwent cine and 4D flow CMR. Relative flow components (direct flow, retained inflow, delayed ejection flow, residual volume) and multiple phasic KEiEDV (LV global, peak systolic, systolic, diastolic, peak E-wave, peak A-wave) were analyzed. Sex-and age-specific reference ranges were reported.Results: Relative flow components and systolic phase KEiEDV did not vary with age. Women had higher retained inflow and peak E-wave KEiEDV, lower residual volume, peak systolic and systolic KEiEDV than men. Peak A-wave KEiEDV increased significantly (r = 0.474) whereas peak E-wave KEiEDV (r = -0.458) and E-wave/A-wave ratio (r = -0.528) decreased with age. A sub-population (n = 44) was compared with 44 sex-and age-matched Caucasian subjects: no significant group differences were observed for all 4D flow CMR parameters.Conclusion: Asian sex-and age-specific 4D flow CMR reference ranges were established. Sex differences in retained inflow, residual volume, peak systolic, systolic KEiEDV and peak E-wave KEiEDV were observed. Ageing influenced diastolic KEiEDV but not systolic phase KEiEDV or relative flow components. All studied parameters were similar between sex-and age-matched Asian and Caucasian subjects, implying generalizability of the ranges. (C) 2021 Elsevier B.V. All rights reserved. Show less
OBJECTIVES In patients with the Fontan circulation, systemic venous return flows passively towards the lungs. Because of the absence of the subpulmonary ventricle, favourable blood flow patterns... Show moreOBJECTIVES In patients with the Fontan circulation, systemic venous return flows passively towards the lungs. Because of the absence of the subpulmonary ventricle, favourable blood flow patterns with minimal energy loss are clinically relevant. The region where the inferior vena cava, the hepatic veins and the extracardiac conduit join (IVC-conduit junction) is a potential source of increased energy loss. The aim of this study was to evaluate the relationship between geometry and blood flow patterns in the IVC-conduit junction with associated kinetic energy and energy loss using 4-dimensional flow magnetic resonance imaging (MRI).METHODS Fourteen extracardiac conduit-Fontan patients underwent 4-dimensional flow MRI. The IVC-conduit junctions were ranked into 3 groups for 3 categories: the geometry, the flow complexity and the conduit mean velocity. The relative increase in the mean velocity from the IVC to the conduit (representing IVC-conduit mismatch) was determined. The peak kinetic energy and mean kinetic energy and energy loss were determined and normalized for volume.RESULTS In 4 of 14 patients, adverse geometries led to helical flow patterns and/or acute changes in flow direction. For each category, the most adverse IVC-conduit junctions were associated with an approximate 2.3-3.2-fold and 2.0-2.9-fold increase in kinetic energy and energy loss, respectively. The IVC-conduit mismatch is strongly correlated with the mean kinetic energy and energy loss (r=0.80, P=0.001 and rho=0.83, P<0.001, respectively) and with body surface area in patients with 16-mm conduits (r=0.88, P=0.010).CONCLUSIONS The IVC-conduit junction is a potential source of increased energy loss. Junctions with increased energy loss showed: (i) a distorted geometry leading to adverse blood flow patterns and/or (ii) the IVC-conduit mismatch. Sixteen-millimetre conduits appear to be inadequate for older patients. Show less
Kamphuis, V.P.; Westenberg, J.M.; Palen, R.L.F. van der; Boogaard, P.J. van den; Geest, R.J. van der; Roos, A. de; ... ; Elbaz, M.S.M. 2018