Objective. To determine the incidence, management, complications, and outcome in neonates with thrombotic events. Study Design. We performed a retrospective study of all neonates with thrombotic... Show moreObjective. To determine the incidence, management, complications, and outcome in neonates with thrombotic events. Study Design. We performed a retrospective study of all neonates with thrombotic events admitted to our neonatal intensive care unit from January 2004 to July 2010. Results. Thrombotic events were identified in 32 of 4734 neonates (0.7%). Seven neonates were managed expectantly and 25 neonates received anticoagulant treatment. Complete resolution of the clot within 3 months of age was found in 68% (17/25) of the treated and in 86% (6/7) of the nontreated neonates. Major complications due to anticoagulant therapy occurred in 3/25 cases (12%) and included severe hemorrhage (n = 2) and abscess at the injection site (n = 1). Conclusion. Complete or partial clot resolution in neonatal thrombosis occurred in both the treated group and nontreated group. Randomized controlled trials are warranted to determine the optimal management in neonatal thrombosis. Show less
This study compares the methods of Dunn and Shukla in determining the appropriate insertion length of umbilical catheters. In July 2007 we changed our policy for umbilical catheter insertions from... Show moreThis study compares the methods of Dunn and Shukla in determining the appropriate insertion length of umbilical catheters. In July 2007 we changed our policy for umbilical catheter insertions from the method of Dunn to the method of Shukla. We report our percentage of inaccurate placement of umbilical-vein catheters (UVCs) and umbilical-artery catheters (UACs) before and after the change of policy. In the Dunn-group, 41% (28/69) of UVCs were placed directly in the correct position against 24% (20/84) in the Shukla-group. The position of the catheter-tip of UVCs in the Dunn-group and the Shukla-group was too high in 57% (39/69) and 75% (63/84) of neonates, respectively. UACs in the Dunn-group were placed directly in the correct position in 63% (24/38) compared to the Shukla-group in 87% (39/45) of cases. The position of the catheter-tip of UACs in the Dunn-group and the Shukla-group was too high in 34% (13/38) and 13% (6/45) of neonates, respectively. In conclusion, the Dunn-method is more accurate than the Shukla-method in predicting the insertion length for UVCs, whereas the Shukla-method is more accurate for UACs. Show less