BackgroundBalloon atrial septostomy (BAS) is an emergent and essential cardiac intervention to enhance intercirculatory mixing at atrial level in deoxygenated patients diagnosed with transposition... Show moreBackgroundBalloon atrial septostomy (BAS) is an emergent and essential cardiac intervention to enhance intercirculatory mixing at atrial level in deoxygenated patients diagnosed with transposition of the great arteries (TGA) and restrictive foramen ovale. The recent recall of several BAS catheters and the changes in the European legal framework for medical devices (MDR 2017/745), has led to an overall scarcity of BAS catheters and raised questions about the use, safety, and experience of the remaining NuMED Z-5 BAS catheter.AimsTo evaluate and describe the practice and safety of the Z-5 BAS catheter, and to compare it to the performance of other BAS catheters.MethodsA retrospective single-center cohort encompassing all BAS procedures performed with the Z-5 BAS catheter in TGA patients between 1999 and 2022.ResultsA total of 182 BAS procedures were performed in 179 TGA-newborns at Day 1 (IQR 0–5) days after birth, with median weight of 3.4 (IQR 1.2–5.7) kg. The need for BAS was urgent in 90% of patients. The percentage of BAS procedures performed at bedside increased over time from 9.8% (before 2010) to 67% (2017–2022). Major complication rate was 2.2%, consisting of cerebral infarction (1.6%) and hypovolemic shock (0.5%). The rate of minor complications was 9.3%, including temporary periprocedural AV-block (3.8%), femoral vein thrombosis (2.7%), transient intracardiac thrombus (0.5%), and atrial flutter (2.2%). BAS procedures performed at bedside and in the cardiac catheterization laboratory had similar complication rates.ConclusionsBAS using the Z-5 BAS catheter is both feasible and safe at bedside and at the cardiac catheterization laboratory with minimal major complications. Show less
AimsEarly healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin... Show moreAimsEarly healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). Methods and ResultsA total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). ConclusionsThe early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage. Show less
Huang, J.Y.; Tu, S.X.; Masuda, S.; Ninomiya, K.; Dijkstra, J.; Chu, M.; ... ; Wijns, W. 2022
ObjectivesThe objective of the present study was to compare plaque burden (PB) calculated from optical coherence tomography (OCT) using deep learning (DL) with PB derived from co-registered... Show moreObjectivesThe objective of the present study was to compare plaque burden (PB) calculated from optical coherence tomography (OCT) using deep learning (DL) with PB derived from co-registered intravascular ultrasound (IVUS). BackgroundA DL algorithm was developed for automated plaque characterization and PB quantification from OCT images. However, the performance of this algorithm for PB quantification has not been validated. MethodsFive-year follow-up OCT and IVUS images from 15 patients implanted with bioresorbable vascular scaffold (BVS) at baseline were analyzed. Precise co-registration for 72 anatomical slices was achieved utilizing unique BVS radiopaque markers. PB derived from OCT DL and IVUS were compared. OCT cross-sections were divided into four subgroups with different media visibility level. The impact of media visibility on the numerical difference between OCT-derived and IVUS-derived PB was investigated. The stent sizes selected by OCT DL and IVUS were compared. ResultsSixty-four paired OCT and IVUS cross-sections were compared. OCT DL showed good concordance with IVUS for PB assessment (ICC = 0.81, difference = -3.53 +/- 6.17%, p < 0.001). The numerical difference between OCT DL-derived PB and IVUS-derived PB was not substantially impacted by missing segments of media visualization (p = 0.21). OCT DL showed a diagnostic accuracy of 92% in identifying PB > 65%. The stent sizes selected by OCT DL were smaller compared to the ones selected by IVUS (difference = 0.30 +/- 0.34 mm, p < 0.001). ConclusionsThe DL algorithm provides a feasible and reliable method for automated PB estimation from OCT, irrespective of media visibility. OCT DL showed good diagnostic accuracy in identifying PB > 65%, revealing its potential to complement conventional OCT imaging. Show less
Bingen, B.O.; Amri, I. al; Montero Cabezas, J.M.; Kley, F. van der 2022
Coronary access difficulty and stent compression by the juxtaposed aortic valve leaflet hamper percutaneous management of delayed coronary artery obstruction (CAO) after valve-in-valve (Edwards... Show moreCoronary access difficulty and stent compression by the juxtaposed aortic valve leaflet hamper percutaneous management of delayed coronary artery obstruction (CAO) after valve-in-valve (Edwards Sapien 3 in St. Jude Trifecta) transcatheter aortic valve replacement (TAVR). Here, we present a case of delayed post-TAVR CAO treated with intravascular lithotripsy and multistenting to overcome stent compression by the adjacent calcified leaflet. Show less
Objective The present study evaluated the effect of endovascular administration of calcium chloride to the carotid artery of swines, to create a model of arterial calcification. Methods Fifteen... Show moreObjective The present study evaluated the effect of endovascular administration of calcium chloride to the carotid artery of swines, to create a model of arterial calcification. Methods Fifteen Large White pigs were used for the study. Via endovascular treatment, carotid arteries were exposed during 9 min to either calcium chloride (experimental artery) or saline (control artery) with the use of the TAPAS catheter. Intravascular ultrasound (IVUS) imaging was obtained at baseline, postprocedure and at 30 days. Optical coherence tomography (OCT) imaging was obtained in vitro after carotids were harvested. Longitudinally cut parallel arterial segments were placed in a system of delicate clamps and underwent uniaxial strain test. All arteries underwent histopathological examination. Results Calcium chloride treated segments showed extensive circumferential parietal calcification evident on both IVUS and OCT. Reduction in minimal lumen area on IVUS was evident in experimental arteries both at 24 hr and 30 days postprocedure. Histopathologic assessment (Von Kossa stain) confirmed medial calcification with mild intimal thickening. Biomechanical testing showed treated segments to have smaller breaking strength and less elastic deformation than controls. Conclusion We developed a nonexpensive, reproducible model of early carotid medial calcification in pigs. Our model has the potential to help the development of research to unravel mechanisms underlying arterial calcification, the use of current or new devices to treat calcified lesions as well as to serve as an option for training interventionalists on the use of such devices. Show less
Objectives We aimed to evaluate the effect of technical aspects of fetal aortic valvuloplasty (FAV) on procedural risks and pregnancy outcomes.Background FAV is performed in cases of severe mid... Show moreObjectives We aimed to evaluate the effect of technical aspects of fetal aortic valvuloplasty (FAV) on procedural risks and pregnancy outcomes.Background FAV is performed in cases of severe mid-gestation aortic stenosis with the goal of preventing hypoplastic left heart syndrome (HLHS).Methods The International Fetal Cardiac Intervention Registry was queried for fetuses who underwent FAV from 2002 to 2018, excluding one high-volume center.Results The 108 fetuses had an attempted cardiac puncture (mean gestational age [GA] 26.1 +/- 3.3 weeks). 83.3% of attempted interventions were technically successful (increased forward flow/new aortic insufficiency). The interventional cannula was larger than 19 g in 70.4%. More than one cardiac puncture was performed in 25.0%. Intraprocedural complications occurred in 48.1%, including bradycardia (34.1%), pericardial (22.2%) or pleural effusion (2.7%) requiring drainage, and balloon rupture (5.6%). Death within 48 hr occurred in 16.7% of fetuses. Of the 81 patients born alive, 59 were discharged home, 34 of whom had biventricular circulation. More than one cardiac puncture was associated with higher complication rates (p < .001). Larger cannula size was associated with higher pericardial effusion rates (p = .044). On multivariate analysis, technical success (odds ratio [OR] = 10.9, 95% confidence interval [CI] = 2.2-53.5, p = .003) and later GA at intervention (OR = 1.5, 95% CI = 1.2-1.9, p = .002) were associated with increased odds of live birth.Conclusions FAV is an often successful but high-risk procedure. Multiple cardiac punctures are associated with increased complication and fetal mortality rates. Later GA at intervention and technical success were independently associated with increased odds of live birth. However, performing the procedure later in gestation may miss the window to prevent progression to HLHS. Show less