AimsDuring the diagnostic work-up of patients with idiopathic ventricular fibrillation (VF), next-generation sequencing panels can be considered to identify genotypes associated with arrhythmias.... Show moreAimsDuring the diagnostic work-up of patients with idiopathic ventricular fibrillation (VF), next-generation sequencing panels can be considered to identify genotypes associated with arrhythmias. However, consensus for gene panel testing is still lacking, and variants of uncertain significance (VUS) are often identified. The aim of this study was to evaluate genetic testing and its results in idiopathic VF patients.Methods and resultsWe investigated 419 patients with available medical records from the Dutch Idiopathic VF Registry. Genetic testing was performed in 379 (91%) patients [median age at event 39 years (27–51), 60% male]. Single-gene testing was performed in 87 patients (23%) and was initiated more often in patients with idiopathic VF before 2010. Panel testing was performed in 292 patients (77%). The majority of causal (likely) pathogenic variants (LP/P, n = 56, 15%) entailed the DPP6 risk haplotype (n = 39, 70%). Moreover, 10 LP/P variants were found in cardiomyopathy genes (FLNC, MYL2, MYH7, PLN (two), TTN (four), RBM20), and 7 LP/P variants were identified in genes associated with cardiac arrhythmias (KCNQ1, SCN5A (2), RYR2 (four)). For eight patients (2%), identification of an LP/P variant resulted in a change of diagnosis. In 113 patients (30%), a VUS was identified. Broad panel testing resulted in a higher incidence of VUS in comparison to single-gene testing (38% vs. 3%, P < 0.001).ConclusionAlmost all patients from the registry underwent, albeit not broad, genetic testing. The genetic yield of causal LP/P variants in idiopathic VF patients is 5%, increasing to 15% when including DPP6. In specific cases, the LP/P variant is the underlying diagnosis. A gene panel specifically for idiopathic VF patients is proposed. Show less
AimsSudden cardiac death (SCD) is challenging to predict. Electrocardiogram (ECG)-derived heart rate-corrected QT-interval (QTc) is used for SCD-risk assessment. QTc is preferably determined... Show moreAimsSudden cardiac death (SCD) is challenging to predict. Electrocardiogram (ECG)-derived heart rate-corrected QT-interval (QTc) is used for SCD-risk assessment. QTc is preferably determined manually, but vendor-provided automatic results from ECG recorders are convenient. Agreement between manual and automatic assessments is unclear for populations with aberrant QTc. We aimed to systematically assess pairwise agreement of automatic and manual QT-intervals and QTc.Methods and resultsA multi-centre cohort enriching aberrant QTc comprised ECGs of healthy controls and long-QT syndrome (LQTS) patients. Manual QT-intervals and QTc were determined by the tangent and threshold methods and compared to automatically generated, vendor-provided values. We assessed agreement globally by intra-class correlation coefficients and pairwise by Bland–Altman analyses and 95% limits of agreement (LoA). Further, manual results were compared to a novel automatic QT-interval algorithm. ECGs of 1263 participants (720 LQTS patients; 543 controls) were available [median age 34 (inter-quartile range 35) years, 55% women]. Comparing cohort means, automatic and manual QT-intervals and QTc were similar. However, pairwise Bland–Altman-based agreement was highly discrepant. For QT-interval, LoAs spanned 95 (tangent) and 92 ms (threshold), respectively. For QTc, the spread was 108 and 105 ms, respectively. LQTS patients exhibited more pronounced differences. For automatic QTc results from 440–540 ms (tangent) and 430–530 ms (threshold), misassessment risk was highest. Novel automatic QT-interval algorithms may narrow this range.ConclusionPairwise vendor-provided automatic and manual QT-interval and QTc results can be highly discrepant. Novel automatic algorithms may improve agreement. Within the above ranges, automatic QT-interval and QTc results require manual confirmation, particularly if T-wave morphology is challenging. Show less
BACKGROUND:Genetic variants in TNNI3K (troponin-I interacting kinase) have previously been associated with dilated cardiomyopathy (DCM), cardiac conduction disease, and supraventricular... Show moreBACKGROUND:Genetic variants in TNNI3K (troponin-I interacting kinase) have previously been associated with dilated cardiomyopathy (DCM), cardiac conduction disease, and supraventricular tachycardias. However, the link between TNNI3K variants and these cardiac phenotypes shows a lack of consensus concerning phenotype and protein function. METHODS:We describe a systematic retrospective study of a cohort of patients undergoing genetic testing for cardiac arrhythmias and cardiomyopathy including TNNI3K. We further performed burden testing of TNNI3K in the UK Biobank. For 2 novel TNNI3K variants, we tested cosegregation. TNNI3K kinase function was estimated by TNNI3K autophosphorylation assays. RESULTS:We demonstrate enrichment of rare coding TNNI3K variants in DCM patients in the Amsterdam cohort. In the UK Biobank, we observed an association between TNNI3K missense (but not loss-of-function) variants and DCM and atrial fibrillation. Furthermore, we demonstrate genetic segregation for 2 rare variants, TNNI3K-p.Ile512Thr and TNNI3K-p.His592Tyr, with phenotypes consisting of DCM, cardiac conduction disease, and supraventricular tachycardia, together with increased autophosphorylation. In contrast, TNNI3K-p.Arg556_Asn590del, a likely benign variant, demonstrated depleted autophosphorylation. CONCLUSIONS:Our findings demonstrate an increased burden of rare coding TNNI3K variants in cardiac patients with DCM. Furthermore, we present 2 novel likely pathogenic TNNI3K variants with increased autophosphorylation, suggesting that enhanced autophosphorylation is likely to drive pathogenicity. Show less
BackgroundAdequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical... Show moreBackgroundAdequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing.ObjectiveThe purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort.MethodsIn this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ≤2.0 V at implantation and without ≥1.5-V increase at the last follow-up visit.ResultsA total of 179 patients were included (mean age 79 ± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 ± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0–88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%).ConclusionThe long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold. Show less
Bos, T.A.; Piers, S.R.D.; Wessels, M.W.; Houweling, A.C.; Bökenkamp, R.; Bootsma, M.; ... ; European Reference Network Rare 2023
BackgroundThe arrhythmogenic cardiomyopathy (ACM) phenotype, with life-threatening ventricular arrhythmias and heart failure, varies according to genetic aetiology. We aimed to characterise the... Show moreBackgroundThe arrhythmogenic cardiomyopathy (ACM) phenotype, with life-threatening ventricular arrhythmias and heart failure, varies according to genetic aetiology. We aimed to characterise the phenotype associated with the variant c.1211dup (p.Val406Serfs*4) in the plakophilin-2 gene (PKP2) and compare it with previously reported Dutch PKP2 founder variants.MethodsClinical data were collected retrospectively from medical records of 106 PKP2 c.1211dup heterozygous carriers. Using data from the Netherlands ACM Registry, c.1211dup was compared with 3 other truncating PKP2 variants (c.235C > T (p.Arg79*), c.397C > T (p.Gln133*) and c.2489+1G > A (p.?)).ResultsOf the 106 carriers, 47 (44%) were diagnosed with ACM, at a mean age of 41 years. By the end of follow-up, 29 (27%) had experienced sustained ventricular arrhythmias and 12 (11%) had developed heart failure, with male carriers showing significantly higher risks than females on these endpoints (p < 0.05). Based on available cardiac magnetic resonance imaging and echocardiographic data, 46% of the carriers showed either right ventricular dilatation and/or dysfunction, whereas a substantial minority (37%) had some form of left ventricular involvement. Both geographical distribution of carriers and haplotype analysis suggested PKP2 c.1211dup to be a founder variant originating from the South-Western coast of the Netherlands. Finally, a Cox proportional hazards model suggested significant differences in ventricular arrhythmia-free survival between 4 PKP2 founder variants, including c.1211dup.ConclusionsThe PKP2 c.1211dup variant is a Dutch founder variant associated with a typical right-dominant ACM phenotype, but also left ventricular involvement, and a possibly more severe phenotype than other Dutch PKP2 founder variants. Show less
BackgroundAn elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes... Show moreBackgroundAn elegant bedside provocation test has been shown to aid the diagnosis of long‐QT syndrome (LQTS) in a retrospective cohort by evaluation of QT intervals and T‐wave morphology changes resulting from the brief tachycardia provoked by standing. We aimed to prospectively determine the potential diagnostic value of the standing test for LQTS.Methods and ResultsIn adults suspected for LQTS who had a standing test, the QT interval was assessed manually and automated. In addition, T‐wave morphology changes were determined. A total of 167 controls and 131 genetically confirmed patients with LQTS were included. A prolonged heart rate–corrected QT interval (QTc) (men ≥430 ms, women ≥450 ms) at baseline before standing yielded a sensitivity of 61% (95% CI, 47–74) in men and 54% (95% CI, 42–66) in women, with a specificity of 90% (95% CI, 80–96) and 89% (95% CI, 81–95), respectively. In both men and women, QTc≥460 ms after standing increased sensitivity (89% [95% CI, 83–94]) but decreased specificity (49% [95% CI, 41–57]). Sensitivity further increased (P<0.01) when a prolonged baseline QTc was accompanied by a QTc≥460 ms after standing in both men (93% [95% CI, 84–98]) and women (90% [95% CI, 81–96]). However, the area under the curve did not improve. T‐wave abnormalities after standing did not further increase the sensitivity or the area under the curve significantly.ConclusionsDespite earlier retrospective studies, a baseline ECG and the standing test in a prospective evaluation displayed a different diagnostic profile for congenital LQTS but no unequivocal synergism or advantage. This suggests that there is markedly reduced penetrance and incomplete expression in genetically confirmed LQTS with retention of repolarization reserve in response to the brief tachycardia provoked by standing. Show less
Background: Variants in KCNH2, encoding the human ether a-go-go (hERG) channel that is responsible for the rapid component of the cardiac delayed rectifier K+ current (IKr), are causal to long QT... Show moreBackground: Variants in KCNH2, encoding the human ether a-go-go (hERG) channel that is responsible for the rapid component of the cardiac delayed rectifier K+ current (IKr), are causal to long QT syndrome type 2 (LQTS2). We identified eight index patients with a new variant of unknown significance (VUS), KCNH2:c.2717C > T:p.(Ser906Leu). We aimed to elucidate the biophysiological effect of this variant, to enable reclassification and consequent clinical decision-making.Methods: A genotype-phenotype overview of the patients and relatives was created. The biophysiological effects were assessed independently by manual-, and automated calibrated patch clamp. HEK293a cells expressing (i) wild-type (WT) KCNH2, (ii) KCNH2-p.S906L alone (homozygous, Hm) or (iii) KCNH2-p.S906L in combination with WT (1:1) (heterozygous, Hz) were used for manual patching. Automated patch clamp measured the variants function against known benign and pathogenic variants, using Flp-In T-rex HEK293 KCNH2-variant cell lines.Results: Incomplete penetrance of LQTS2 in KCNH2:p.(Ser906Leu) carriers was observed. In addition, some patients were heterozygous for other VUSs in CACNA1C, PKP2, RYR2 or AKAP9. The phenotype of carriers of KCNH2:p.(Ser906Leu) ranged from asymptomatic to life-threatening arrhythmic events. Manual patch clamp showed a reduced current density by 69.8 and 60.4% in KCNH2-p.S906L-Hm and KCNH2-p.S906L-Hz, respectively. The time constant of activation was significantly increased with 80.1% in KCNH2-p.S906L-Hm compared with KCNH2-WT. Assessment of KCNH2-p.S906L-Hz by calibrated automatic patch clamp assay showed a reduction in current density by 35.6%.Conclusion: The reduced current density in the KCNH2-p.S906L-Hz indicates a moderate loss-of-function. Combined with the reduced penetrance and variable phenotype, we conclude that KCNH2:p.(Ser906Leu) is a low penetrant likely pathogenic variant for LQTS2. Show less
Aims: Stereotactic arrhythmia radiotherapy (STAR) is suggested as potentially effective and safe treatment for patients with therapy-refractory ventricular tachycardia (VT). However, the current... Show moreAims: Stereotactic arrhythmia radiotherapy (STAR) is suggested as potentially effective and safe treatment for patients with therapy-refractory ventricular tachycardia (VT). However, the current prospective knowledge base and experience with STAR is limited. In this study we aimed to prospectively evaluate the efficacy and safety of STAR. Methods and results: The StereoTactic Arrhythmia Radiotherapy in the Netherlands no.1 was a pre-post intervention study to prospectively evaluate efficacy and safety of STAR. In patients with therapy-refractory VT, the pro-arrhythmic region was treated with a 25 Gy single radiotherapy fraction. The main efficacy measure was a reduction in the number of treated VT-episodes by >= 50%, comparing the 12 months before and after treatment (or end of follow-up, excluding a 6-week blanking period). The study was deemed positive when >= 50% of patients would meet this criterion. Safety evaluation included left ventricular ejection fraction, pulmonary function, and adverse events. Six male patients with an ischaemic cardiomyopathy were enrolled, and median age was 73 years (range 54-83). Median left ventricular ejection fraction was 38% (range 24-52). The median planning target volume was 187 mL (range 93-372). Four (67%) patients completed the 12-month follow-up, and two patients died (not STAR related) during follow-up. The main efficacy measure of >= 50% reduction in treated VT-episodes at the end of follow-up was achieved in four patients (67%). The median number of treated VT-episodes was reduced by 87%. No reduction in left ventricular ejection fraction or pulmonary function was observed. No treatment related serious adverse events occurred. Conclusions: STAR resulted in a >= 50% reduction in treated VT-episodes in 4/6 (67%) patients. No reduction in cardiac and pulmonary function nor treatment-related serious adverse events were observed during follow-up. Show less
Peltenburg, P.J.; Pultoo, S.N.J.; Tobert, K.E.; Bos, J.M.; Lieve, K.V.V.; Tanck, M.; ... ; Werf, C. van der 2023
Aims In catecholaminergic polymorphic ventricular tachycardia (CPVT), the exercise-stress test (EST) is the cornerstone for the diagnosis, risk stratification, and assessment of therapeutic... Show moreAims In catecholaminergic polymorphic ventricular tachycardia (CPVT), the exercise-stress test (EST) is the cornerstone for the diagnosis, risk stratification, and assessment of therapeutic efficacy, but its repeatability is unknown. We aimed to test the repeatability of ventricular arrhythmia characteristics on the EST in patients with CPVT. Methods and results EST-pairs (ESTs performed within 18 months between 2005 and 2021, on the same protocol, and without or on the exact same treatment) of patients with RYR2-mediated CPVT from two specialized centres were included. The primary endpoint was the repeatability of the maximum ventricular arrhythmia score [VAS: 0 for the absence of premature ventricular contractions (PVCs); 1 for isolated PVCs; 2 for bigeminal PVCs; 3 for couplets; and 4 for non-sustained ventricular tachycardia]. Secondary outcomes were the repeatability of the heart rate at the first PVC and the Delta VAS (the absolute difference in VAS between the EST-pairs). A total of 104 patients with 349 EST-pairs were included. The median duration between ESTs was 343 (interquartile range, 189-378) days. Sixty (17.2%) EST-pairs were off therapy. The repeatability of the VAS was moderate {Krippendorf alpha, 0.56 [95% confidence interval (CI), 0.48-0.64]}, and the repeatability of the heart rate at the first PVC was substantial [intra-class correlation coefficient, 0.78 (95% CI, 0.71-0.84)]. The use of medication was associated with a higher odds for a Delta VAS > 1 (odds ratio = 3.52; 95% CI, 2.46-4.57; P = 0.020). Conclusion The repeatability of ventricular arrhythmia characteristics was moderate to substantial. This underlines the need for multiple ESTs in CPVT patients and CPVT suspicious patients and it provides the framework for assessing the therapeutic efficacy of novel CPVT therapies. Show less
Background:Truncating variants in desmoplakin (DSPtv) are an important cause of arrhythmogenic cardiomyopathy; however the genetic architecture and genotype-specific risk factors are incompletely... Show moreBackground:Truncating variants in desmoplakin (DSPtv) are an important cause of arrhythmogenic cardiomyopathy; however the genetic architecture and genotype-specific risk factors are incompletely understood. We evaluated phenotype, risk factors for ventricular arrhythmias, and underlying genetics of DSPtv cardiomyopathy. Methods:Individuals with DSPtv and any cardiac phenotype, and their gene-positive family members were included from multiple international centers. Clinical data and family history information were collected. Event-free survival from ventricular arrhythmia was assessed. Variant location was compared between cases and controls, and literature review of reported DSPtv performed. Results:There were 98 probands and 72 family members (mean age at diagnosis 43 +/- 8 years, 59% women) with a DSPtv, of which 146 were considered clinically affected. Ventricular arrhythmia (sudden cardiac arrest, sustained ventricular tachycardia, appropriate implantable cardioverter defibrillator therapy) occurred in 56 (33%) individuals. DSPtv location and proband status were independent risk factors for ventricular arrhythmia. Further, gene region was important with variants in cases (cohort n=98; Clinvar n=167) more likely to occur in the regions resulting in nonsense mediated decay of both major DSP isoforms, compared with n=124 genome aggregation database control variants (148 [83.6%] versus 29 [16.4%]; P<0.0001). Conclusions:In the largest series of individuals with DSPtv, we demonstrate that variant location is a novel risk factor for ventricular arrhythmia, can inform variant interpretation, and provide critical insights to allow for precision-based clinical management. Show less
Gasperetti, A.; Carrick, R.T.; Costa, S.; Compagnucci, P.; Bosman, L.P.; Chivulescu, M.; ... ; Cadrin-Tourigny, J. 2022
Background: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with... Show moreBackground: A novel risk calculator based on clinical characteristics and noninvasive tests that predicts the onset of clinical sustained ventricular arrhythmias (VA) in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) has been proposed and validated by recent studies. It remains unknown whether programmed ventricular stimulation (PVS) provides additional prognostic value. Methods: All patients with a definite ARVC diagnosis, no history of sustained VAs at diagnosis, and PVS performed at baseline were extracted from 6 international ARVC registries. The calculator-predicted risk for sustained VA (sustained or implantable cardioverter defibrillator treated ventricular tachycardia [VT] or fibrillation, [aborted] sudden cardiac arrest) was assessed in all patients. Independent and combined performance of the risk calculator and PVS on sustained VA were assessed during a 5-year follow-up period. Results: Two hundred eighty-eight patients (41.0 +/- 14.5 years, 55.9% male, right ventricular ejection fraction 42.5 +/- 11.1%) were enrolled. At PVS, 137 (47.6%) patients had inducible ventricular tachycardia. During a median of 5.31 [2.89-10.17] years of follow-up, 83 (60.6%) patients with a positive PVS and 37 (24.5%) with a negative PVS experienced sustained VA (P<0.001). Inducible ventricular tachycardia predicted clinical sustained VA during the 5-year follow-up and remained an independent predictor after accounting for the calculator-predicted risk (HR, 2.52 [1.58-4.02]; P<0.001). Compared with ARVC risk calculator predictions in isolation (C-statistic 0.72), addition of PVS inducibility showed improved prediction of VA events (C-statistic 0.75; log-likelihood ratio for nested models, P<0.001). PVS inducibility had a 76% [67-84] sensitivity and 68% [61-74] specificity, corresponding to log-likelihood ratios of 2.3 and 0.36 for inducible (likelihood ratio+) and noninducible (likelihood ratio-) patients, respectively. In patients with a ARVC risk calculator-predicted risk of clinical VA events <25% during 5 years (ie, low/intermediate subgroup), PVS had a 92.6% negative predictive value. Conclusions: PVS significantly improved risk stratification above and beyond the calculator-predicted risk of VA in a primary prevention cohort of patients with ARVC, mainly for patients considered to be at low and intermediate risk by the clinical risk calculator. Show less
Brugada syndrome (BrS) is a rare inherited arrhythmia syndrome. Affected children may experience life-threatening symptoms, mainly during fever. The percentage of SCN5A variant carriers in children... Show moreBrugada syndrome (BrS) is a rare inherited arrhythmia syndrome. Affected children may experience life-threatening symptoms, mainly during fever. The percentage of SCN5A variant carriers in children is higher than in adults. Current diagnostic and follow-up policies for children with (a family history of) BrS vary between centres. Here, we present a consensus statement based on the current literature and expert opinions to standardise the approach for all children with BrS and those from BrS families in the Netherlands. In summary, BrS is diagnosed in patients with a spontaneous type 1 electrocardiogram (ECG) pattern or with a Shanghai score >= 3.5 including >= 1 ECG finding. A sodium channel-blocking drug challenge test should only be performed after puberty with a few exceptions. A fever ECG is indicated in children with suspected BrS, in children with a first-degree family member with definite or possible BrS according to the Shanghai criteria with a SCN5A variant and in paediatric SCN5A variant carriers. In-hospital rhythm monitoring during fever is indicated in patients with an existing type 1 ECG pattern and in those who develop such a pattern. Genetic testing should be restricted to SCN5A. Children with BrS and children who carry an SCN5A variant should avoid medication listed at and fever should be suppressed. Ventricular arrhythmias or electrical storms should be treated with isoproterenol infusion. Show less
Theuns, D.A.; Verstraelen, T.E.; Lingen, A.C.J. van der; Delnoy, P.P.; Allaart, C.P.; Erven, L. van; ... ; Meeder, J.G. 2022
Background: Primary prophylactic implantable cardioverter-defibrillators (ICDs) in patients with non-ischaemic cardiomyopathy (NICMP) remains controversial. This study sought to assess the benefit... Show moreBackground: Primary prophylactic implantable cardioverter-defibrillators (ICDs) in patients with non-ischaemic cardiomyopathy (NICMP) remains controversial. This study sought to assess the benefit of ICD therapy with or without cardiac resynchronisation therapy (CRT) in patients with NICMP. In addition, data were compared with real-world clinical data to perform a risk/benefit analysis. Methods: Relevant randomised clinical trials (RCTs) published in meta-analyses since DANISH, and in PubMed, EMBASE and Cochrane databases from 2016 to 2020 were identified. The benefit of ICD therapy stratified by CRT use was assessed using random effects meta-analysis techniques. Results: Six RCTs were included in the meta-analysis. Among patients without CRT, ICD use was associated with a 24% reduction in mortality (hazard ratio [HR]: 0.76; 95% confidence interval [CI]: 0.62-0.93; P = 0.008). In contrast, among patients with CRT, a CRT-defibrillator was not associated with reduced mortality (HR: 0.74, 95% CI 0.47-1.16; P = 0.19). For ICD therapy without CRT, absolute risk reduction at 3-years follow-up was 3.7% yielding a number needed to treat of 27. Conclusion: ICD use significantly improved survival among patients with NICMP who are not eligible for CRT. Considering CRT, the addition of defibrillator therapy was not significantly associated with mortality benefit compared with CRT pacemaker. Show less
Aims Human-induced pluripotent stem cell-cardiomyocytes (hiPSC-CMs) are widely used to study arrhythmia-associated mutations in ion channels. Among these, the cardiac sodium channel SCN5A undergoes... Show moreAims Human-induced pluripotent stem cell-cardiomyocytes (hiPSC-CMs) are widely used to study arrhythmia-associated mutations in ion channels. Among these, the cardiac sodium channel SCN5A undergoes foetal-to-adult isoform switching around birth. Conventional hiPSC-CM cultures, which are phenotypically foetal, have thus far been unable to capture mutations in adult gene isoforms. Here, we investigated whether tri-cellular cross-talk in a three-dimensional (3D) cardiac microtissue (MT) promoted post-natal SCN5A maturation in hiPSC-CMs. Methods and results We derived patient hiPSC-CMs carrying compound mutations in the adult SCN5A exon 6B and exon 4. Electrophysiological properties of patient hiPSC-CMs in monolayer were not altered by the exon 6B mutation compared with isogenic controls since it is not expressed; further, CRISPR/Cas9-mediated excision of the foetal exon 6A did not promote adult SCN5A expression. However, when hiPSC-CMs were matured in 3D cardiac MTs, SCN5A underwent isoform switch and the functional consequences of the mutation located in exon 6B were revealed. Up-regulation of the splicing factor muscleblind-like protein 1 (MBNL1) drove SCN5A post-natal maturation in microtissues since its overexpression in hiPSC-CMs was sufficient to promote exon 6B inclusion, whilst knocking-out MBNL1 failed to foster isoform switch. Conclusions Our study shows that (i) the tri-cellular cardiac microtissues promote post-natal SCN5A isoform switch in hiPSC-CMs, (ii) adult splicing of SCN5A is driven by MBNL1 in these tissues, and (iii) this model can be used for examining post-natal cardiac arrhythmias due to mutations in the exon 6B. Translational perspective The cardiac sodium channel is essential for conducting the electrical impulse in the heart. Postnatal alternative splicing regulation causes mutual exclusive inclusion of fetal or adult exons of the corresponding gene, SCN5A. Typically, immature hiPSCCMs fall short in studying the effect of mutations located in the adult exon. We describe here that an innovative tri-cellular three-dimensional cardiac microtissue culture promotes hiPSC-CMs maturation through upregulation of MBNL1, thus revealing the effect of a pathogenic genetic variant located in the SCN5A adult exon. These results help advancing the use of hiPSC-CMs in studying adult heart disease and for developing personalized medicine applications. Show less
Aims: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation... Show moreAims: Arrhythmogenic right ventricular cardiomyopathy (ARVC) patients have an increased risk of ventricular arrhythmias (VA). Four implantable cardioverter-defibrillator (ICD) recommendation algorithms are available The International Task Force Consensus ('ITFC'), an ITFC modification by Orgeron et al. ('mITFC'), the AHA/HRS/ACC guideline for VA management ('AHA'), and the HRS expert consensus statement ('HRS'). This study aims to validate and compare the performance of these algorithms in ARVC. Methods and results: We classified 617 definite ARVC patients (38.5 +/- 15.1 years, 52.4% male, 39.2% prior sustained VA) according to four algorithms. Clinical performance was evaluated by sensitivity, specificity, ROC-analysis, and decision curve analysis for any sustained VA and for fast VA (>250 b.p.m.). During 6.4 [2.8-11.5] years follow-up, 282 (45.7%) patients experienced any sustained VA, and 63 (10.2%) fast VA. For any sustained VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (94.0-97.8% vs. 76.7-83.5%), but lower specificity (15.9-32.0% vs. 42.7%-60.1%). Similarly, for fast VA, ITFC and mITFC provide higher sensitivity than AHA and HRS (95.2-97.1% vs. 76.7-78.4%) but lower specificity (42.7-43.1 vs. 76.7-78.4%). Decision curve analysis showed ITFC and mITFC to be superior for a 5-year sustained VA risk ICD indication threshold between 5-25% or 2-9% for fast VA. Conclusion: The ITFC and mITFC provide the highest protection rates, whereas AHA and HRS decrease unnecessary ICD placements. ITFC or mITFC should be used if we consider the 5-year threshold for ICD indication to lie within 5-25% for sustained VA or 2-9% for fast VA. These data will inform decision-making for ICD placement in ARVC. Show less
Background: Symptomatic children with catecholaminergic polymorphic ventricular tachycardia (CPVT) are at risk for recurrent arrhythmic events. beta-Blockers decrease this risk, but studies... Show moreBackground: Symptomatic children with catecholaminergic polymorphic ventricular tachycardia (CPVT) are at risk for recurrent arrhythmic events. beta-Blockers decrease this risk, but studies comparing individual beta-blockers in sizeable cohorts are lacking. We aimed to assess the association between risk for arrhythmic events and type of beta-blocker in a large cohort of symptomatic children with CPVT. Methods: From 2 international registries of patients with CPVT, RYR2 variant-carrying symptomatic children (defined as syncope or sudden cardiac arrest before beta-blocker initiation and age at start of beta-blocker therapy <18 years), treated with a beta-blocker were included. Cox regression analyses with time-dependent covariates for beta-blockers and potential confounders were used to assess the hazard ratio (HR). The primary outcome was the first occurrence of sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter-defibrillator shock, or syncope. The secondary outcome was the first occurrence of any of the primary outcomes except syncope. Results: We included 329 patients (median age at diagnosis, 12 [interquartile range, 7-15] years, 35% females). Ninety-nine (30.1%) patients experienced the primary outcome and 74 (22.5%) experienced the secondary outcome during a median follow-up of 6.7 (interquartile range, 2.8-12.5) years. Two-hundred sixteen patients (66.0%) used a nonselective beta-blocker (predominantly nadolol [n=140] or propranolol [n=70]) and 111 (33.7%) used a beta 1-selective beta-blocker (predominantly atenolol [n=51], metoprolol [n=33], or bisoprolol [n=19]) as initial beta-blocker. Baseline characteristics did not differ. The HRs for both the primary and secondary outcomes were higher for beta 1-selective compared with nonselective beta-blockers (HR, 2.04 [95% CI, 1.31-3.17]; and HR, 1.99 [95% CI, 1.20-3.30], respectively). When assessed separately, the HR for the primary outcome was higher for atenolol (HR, 2.68 [95% CI, 1.44-4.99]), bisoprolol (HR, 3.24 [95% CI, 1.47-7.18]), and metoprolol (HR, 2.18 [95% CI, 1.08-4.40]) compared with nadolol, but did not differ from propranolol. The HR of the secondary outcome was only higher in atenolol compared with nadolol (HR, 2.68 [95% CI, 1.30-5.55]). Conclusions: beta 1-selective beta-blockers were associated with a significantly higher risk for arrhythmic events in symptomatic children with CPVT compared with nonselective beta-blockers, specifically nadolol. Nadolol, or propranolol if nadolol is unavailable, should be the preferred beta-blocker for treating symptomatic children with CPVT. Show less
Background: Symptomatic children with catecholaminergic polymorphic ventricular tachycardia (CPVT) are at risk for recurrent arrhythmic events. beta-Blockers decrease this risk, but studies... Show moreBackground: Symptomatic children with catecholaminergic polymorphic ventricular tachycardia (CPVT) are at risk for recurrent arrhythmic events. beta-Blockers decrease this risk, but studies comparing individual beta-blockers in sizeable cohorts are lacking. We aimed to assess the association between risk for arrhythmic events and type of beta-blocker in a large cohort of symptomatic children with CPVT. Methods: From 2 international registries of patients with CPVT, RYR2 variant-carrying symptomatic children (defined as syncope or sudden cardiac arrest before beta-blocker initiation and age at start of beta-blocker therapy <18 years), treated with a beta-blocker were included. Cox regression analyses with time-dependent covariates for beta-blockers and potential confounders were used to assess the hazard ratio (HR). The primary outcome was the first occurrence of sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter-defibrillator shock, or syncope. The secondary outcome was the first occurrence of any of the primary outcomes except syncope. Results: We included 329 patients (median age at diagnosis, 12 [interquartile range, 7-15] years, 35% females). Ninety-nine (30.1%) patients experienced the primary outcome and 74 (22.5%) experienced the secondary outcome during a median follow-up of 6.7 (interquartile range, 2.8-12.5) years. Two-hundred sixteen patients (66.0%) used a nonselective beta-blocker (predominantly nadolol [n=140] or propranolol [n=70]) and 111 (33.7%) used a beta 1-selective beta-blocker (predominantly atenolol [n=51], metoprolol [n=33], or bisoprolol [n=19]) as initial beta-blocker. Baseline characteristics did not differ. The HRs for both the primary and secondary outcomes were higher for beta 1-selective compared with nonselective beta-blockers (HR, 2.04 [95% CI, 1.31-3.17]; and HR, 1.99 [95% CI, 1.20-3.30], respectively). When assessed separately, the HR for the primary outcome was higher for atenolol (HR, 2.68 [95% CI, 1.44-4.99]), bisoprolol (HR, 3.24 [95% CI, 1.47-7.18]), and metoprolol (HR, 2.18 [95% CI, 1.08-4.40]) compared with nadolol, but did not differ from propranolol. The HR of the secondary outcome was only higher in atenolol compared with nadolol (HR, 2.68 [95% CI, 1.30-5.55]). Conclusions: beta 1-selective beta-blockers were associated with a significantly higher risk for arrhythmic events in symptomatic children with CPVT compared with nonselective beta-blockers, specifically nadolol. Nadolol, or propranolol if nadolol is unavailable, should be the preferred beta-blocker for treating symptomatic children with CPVT. Show less
Andersen-Tawil syndrome (ATS) and Noonan syndrome (NS) are both autosomal dominantly inherited disorders that share anomalies in the same body systems, i.e. cardiovascular system, skeleton, growth,... Show moreAndersen-Tawil syndrome (ATS) and Noonan syndrome (NS) are both autosomal dominantly inherited disorders that share anomalies in the same body systems, i.e. cardiovascular system, skeleton, growth, and face morphology. Here we report a patient meeting clinical diagnostic criteria for NS in whom no variant in one of the genes known to cause NS was found and a pathogenic variant in KCNJ2 (c.653G > C, p.(Arg218Pro)) was demonstrated. Because of manifestations typical for NS and previously not described in ATS (broad neck, low hairline and pectus excavatum), this may indicate there is a phenotypical overlap between ATS and NS, although we cannot exclude that the patient has an additional, hitherto undetected variant in another gene that explains the NS features. Further studies into a functional relation between KCNJ2 and the RAS/MAPK pathway are needed to determine this further. Show less
Aims This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with... Show moreAims This study was performed to develop and externally validate prediction models for appropriate implantable cardioverter-defibrillator (ICD) shock and mortality to identify subgroups with insufficient benefit from ICD implantation.Methods and results We recruited patients scheduled for primary prevention ICD implantation and reduced left ventricular function. Bootstrapping-based Cox proportional hazards and Fine and Gray competing risk models with likely candidate predictors were developed for all-cause mortality and appropriate ICD shock, respectively. Between 2014 and 2018, we included 1441 consecutive patients in the development and 1450 patients in the validation cohort. During a median follow-up of 2.4 (IQR 2.1-2.8) years, 109 (7.6%) patients received appropriate ICD shock and 193 (13.4%) died in the development cohort. During a median follow-up of 2.7 (IQR 2.0-3.4) years, 105 (7.2%) received appropriate ICD shock and 223 (15.4%) died in the validation cohort. Selected predictors of appropriate ICD shock were gender, NSVT, ACE/ARB use, atrial fibrillation history, Aldosterone-antagonist use, Digoxin use, eGFR, (N)OAC use, and peripheral vascular disease. Selected predictors of all-cause mortality were age, diuretic use, sodium, NT-pro-BNP, and ACE/ARB use. C-statistic was 0.61 and 0.60 at respectively internal and external validation for appropriate ICD shock and 0.74 at both internal and external validation for mortality.Conclusion Although this cohort study was specifically designed to develop prediction models, risk stratification still remains challenging and no large group with insufficient benefit of ICD implantation was found. However, the prediction models have some clinical utility as we present several scenarios where ICD implantation might be postponed. Show less
BACKGROUND Adult long QT syndrome (LQTS) patients have inadequate corrected QT interval (QTc) shortening and an abnormal T-wave response to the sudden heart rate acceleration provoked by standing.... Show moreBACKGROUND Adult long QT syndrome (LQTS) patients have inadequate corrected QT interval (QTc) shortening and an abnormal T-wave response to the sudden heart rate acceleration provoked by standing. In adults, this knowledge can be used to aid an LQTS diagnosis and, possibly, for risk stratification. However, data on the diagnostic value of the standing test in children are currently limited. OBJECTIVE To determine the potential value of the standing test to aid LQTS diagnostics in children. METHODS In a prospective cohort including children (<= 18 years) who had a standing test, comprehensive analyses were performed including manual and automated QT interval assessments and determination of T-wave morphology changes. RESULTS We included 47 LQTS children and 86 control children. At baseline, the QTc that identified LQTS children with a 90% sensitivity was 435 ms, which yielded a 65% specificity. A QTc >= 490 ms after standing only slightly increased sensitivity (91%, 95% confidence interval [CI]: 80%-98%) and slightly decreased specificity (58%, 95% CI: 47%-70%). Sensitivity increased slightly more when T-wave abnormalities were present (94%, 95% CI: 82%-99%; specificity 53%, 95% CI: 42%-65%). When a baseline QTc >= 440 ms was accompanied by a QTc >= 490 ms and T-wave abnormalities after standing, sensitivity further increased (96%, 95% CI: 85%-99%) at the expense of a further specificity decrease (41%, 95% CI: 30%-52%). Beat-to-beat analysis showed that 30 seconds after standing, LQTS children had a greater increase in heart rate compared to controls, which was more evidently present in LQTS boys and LQTS type 1 children. CONCLUSION In children, the standing test has limited additive diagnostic value for LQTS over a baseline electrocardiogram, while T-wave abnormalities after standing also have limited additional value. The standing test for LQTS should only be used with caution in children. Show less