There is a pressing need to establish novel biomarkers to predict the progression of thoracic aortic aneurysm (TAA) dilatation. Aside from hemodynamics, the roles of oxygen (O2) and nitric oxide ... Show moreThere is a pressing need to establish novel biomarkers to predict the progression of thoracic aortic aneurysm (TAA) dilatation. Aside from hemodynamics, the roles of oxygen (O2) and nitric oxide (NO) in TAA pathogenesis are potentially significant. As such, it is imperative to comprehend the relationship between aneurysm presence and species distribution in both the lumen and aortic wall. Given the limitations of existing imaging methods, we propose the use of patient-specific computational fluid dynamics (CFD) to explore this relationship. We have performed CFD simulations of O2 and NO mass transfer in the lumen and aortic wall for two cases: a healthy control (HC) and a patient with TAA, both acquired using 4D-flow magnetic resonance imaging (MRI). The mass transfer of O2 was based on active transport by hemoglobin, while the local variations of the wall shear stress (WSS) drove NO production. Comparing hemodynamic properties, the time-averaged WSS was considerably lower for TAA, while the oscillatory shear index and endothelial cell activation potential were notably elevated. O2 and NO showed a non-uniform distribution within the lumen and an inverse correlation between the two species. We identified several locations of hypoxic regions for both cases due to lumen-side mass transfer limitations. In the wall, NO varied spatially, with a clear distinction between TAA and HC. In conclusion, the hemodynamics and mass transfer of NO in the aorta exhibit the potential to serve as a diagnostic biomarker for TAA. Furthermore, hypoxia may provide additional insights into the onset of other aortic pathologies. Show less
Objective: We aim to validate four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) peak velocity tracking methods for measuring the peak velocity of mitral inflow against Doppler... Show moreObjective: We aim to validate four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) peak velocity tracking methods for measuring the peak velocity of mitral inflow against Doppler echocardiography.Method: Fifty patients were recruited who had 4D flow CMR and Doppler Echocardiography. After transvalvular flow segmentation using established valve tracking methods, peak velocity was automatically derived using three-dimensional streamlines of transvalvular flow. In addition, a static-planar method was used at the tip of mitral valve to mimic Doppler technique.Results: Peak E-wave mitral inflow velocity was comparable between TTE and the novel 4D flow automated dynamic method (0.9 +/- 0.5 vs 0.94 +/- 0.6 m/s; p = 0.29) however there was a statistically significant difference when compared with the static planar method (0.85 +/- 0.5 m/s; p = 0.01). Median A-wave peak velocity was also comparable across TTE and the automated dynamic streamline (0.77 +/- 0.4 vs 0.76 +/- 0.4 m/s; p = 0.77). A significant difference was seen with the static planar method (0.68 +/- 0.5 m/s; p = 0.04). E/A ratio was comparable between TTE and both the automated dynamic and static planar method (1.1 +/- 0.7 vs 1.15 +/- 0.5 m/s; p = 0.74 and 1.15 +/- 0.5 m/s; p = 0.5 respectively). Both novel 4D flow methods showed good correlation with TTE for E-wave (dynamic method; r = 0.70; P < 0.001 and static-planar method; r = 0.67; P < 0.001) and A-wave velocity measurements (dynamic method; r = 0.83; P < 0.001 and static method; r = 0.71; P < 0.001). The automated dynamic method demonstrated excellent intra/inter-observer reproducibility for all parameters.Conclusion: Automated dynamic peak velocity tracing method using 4D flow CMR is comparable to Doppler echocardiography for mitral inflow assessment and has excellent reproducibility for clinical use. Show less
Objective: We aim to validate four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) peak velocity tracking methods for measuring the peak velocity of mitral inflow against Doppler... Show moreObjective: We aim to validate four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) peak velocity tracking methods for measuring the peak velocity of mitral inflow against Doppler echocardiography.Method: Fifty patients were recruited who had 4D flow CMR and Doppler Echocardiography. After transvalvular flow segmentation using established valve tracking methods, peak velocity was automatically derived using three-dimensional streamlines of transvalvular flow. In addition, a static-planar method was used at the tip of mitral valve to mimic Doppler technique.Results: Peak E-wave mitral inflow velocity was comparable between TTE and the novel 4D flow automated dynamic method (0.9 +/- 0.5 vs 0.94 +/- 0.6 m/s; p = 0.29) however there was a statistically significant difference when compared with the static planar method (0.85 +/- 0.5 m/s; p = 0.01). Median A-wave peak velocity was also comparable across TTE and the automated dynamic streamline (0.77 +/- 0.4 vs 0.76 +/- 0.4 m/s; p = 0.77). A significant difference was seen with the static planar method (0.68 +/- 0.5 m/s; p = 0.04). E/A ratio was comparable between TTE and both the automated dynamic and static planar method (1.1 +/- 0.7 vs 1.15 +/- 0.5 m/s; p = 0.74 and 1.15 +/- 0.5 m/s; p = 0.5 respectively). Both novel 4D flow methods showed good correlation with TTE for E-wave (dynamic method; r = 0.70; P < 0.001 and static-planar method; r = 0.67; P < 0.001) and A-wave velocity measurements (dynamic method; r = 0.83; P < 0.001 and static method; r = 0.71; P < 0.001). The automated dynamic method demonstrated excellent intra/inter-observer reproducibility for all parameters.Conclusion: Automated dynamic peak velocity tracing method using 4D flow CMR is comparable to Doppler echocardiography for mitral inflow assessment and has excellent reproducibility for clinical use. Show less
Objective Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional... Show moreObjective Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 +/- 35.2 mmHg using the invasive pressure drop method and 52.2 +/- 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography. Show less
Engelhard, S.; Velde, L. van de; Jebbink, E.G.; Jain, K.; Westenberg, J.; Zeebregts, C.J.; ... ; Reijnen, M.M.P.J. 2021
The assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of... Show moreThe assessment of local blood flow patterns in patients with peripheral arterial disease is clinically relevant, since these patterns are related to atherosclerotic disease progression and loss of patency in stents placed in peripheral arteries, through mechanisms such as recirculating flow and low wall shear stress (WSS). However, imaging of vascular flow in these patients is technically challenging due to the often complex flow patterns that occur near atherosclerotic lesions. While several flow quantification techniques have been developed that could improve the outcomes of vascular interventions, accurate 2D or 3D blood flow quantification is not yet used in clinical practice.This article provides an overview of several important topics that concern the quantification of blood flow in patients with peripheral arterial disease. The hemodynamic mechanisms involved in the development of atherosclerosis and the current clinical practice in the diagnosis of this disease are discussed, showing the unmet need for improved and validated flow quantification techniques in daily clinical practice. This discussion is followed by a showcase of state-of-the-art blood flow quantification techniques and how these could be used before, during and after treatment of stenotic lesions to improve clinical outcomes. These techniques include novel ultrasound-based methods, Phase-Contrast Magnetic Resonance Imaging (PC-MRI) and Computational Fluid Dynamics (CFD). The last section discusses future perspectives, with advanced (hybrid) imaging techniques and artificial intelligence, including the implementation of these techniques in clinical practice. Show less
Assessment of right ventricular (RV) diastolic function is not routinely carried out. This is due to standard two-dimensional imaging techniques being unreliable. Four-dimensional flow (4D flow)... Show moreAssessment of right ventricular (RV) diastolic function is not routinely carried out. This is due to standard two-dimensional imaging techniques being unreliable. Four-dimensional flow (4D flow) derived right ventricular blood flow kinetic energy assessment could circumvent the issues of the current imaging modalities. It also remains unknown whether there is an association between right ventricular blood flow kinetic energy (KE) and healthy ageing. We hypothesise that healthy ageing requires maintaining normal RV intra-cavity blood flow as quantified using KE method. The main objective of this study was to investigate the effect of healthy ageing on tricuspid through-plane flow and right ventricular blood flow kinetic energy. In this study, fifty-three healthy participants received a 4D flow cardiovascular magnetic resonance (CMR) scan on 1.5T Philips Ingenia. Cine segmentation and 4D flow analysis were performed using dedicated software. Standard statistical methods were carried out to investigate the associations. Both RV E-wave KEi(EDV) (r=-0.3, P=0.04) and A-wave KEi(EDV) (r=0.42, P<0.01) showed an association with healthy ageing. Additionally, the right ventricular blood flow KEi(EDV) E/A ratio demonstrated the strongest association with healthy ageing (r=-0.53, P<0.01) when compared to all RV functional and haemodynamic parameters. Furthermore, in a multivariate regression model, KEi(EDV) E/A ratio and 4D flow derived tricuspid valve stroke volume demonstrated independent association to healthy ageing (beta -0.02 and 0.68 respectively, P<0.01). Ageing is independently associated with 4D flow derived tricuspid stroke volume and RV blood flow KE E/A ratio. These novel 4D flow CMR derived imaging markers have future potential for RV diastolic assessment. Show less
Mitral regurgitation (MR) is a common valvular heart disease and is the second most frequent indication for heart valve surgery in Western countries. Echocardiography is the recommended first-line... Show moreMitral regurgitation (MR) is a common valvular heart disease and is the second most frequent indication for heart valve surgery in Western countries. Echocardiography is the recommended first-line test for the assessment of valvular heart disease, but cardiovascular magnetic resonance imaging (CMR) provides complementary information, especially for assessing MR severity and to plan the timing of intervention. As new CMR techniques for the assessment of MR have arisen, standardizing CMR protocols for research and clinical studies has become important in order to optimize diagnostic utility and support the wider use of CMR for the clinical assessment of MR. In this Consensus Statement, we provide a detailed description of the current evidence on the use of CMR for MR assessment, highlight its current clinical utility, and recommend a standardized CMR protocol and report for MR assessment.In this Consensus Statement, Garg and colleagues describe the current evidence on the use of cardiovascular magnetic resonance imaging for the assessment of mitral regurgitation, highlight its current clinical utility, and recommend a standardized imaging protocol and report. Show less
Elders, B.; Westenberg, J.; Boogaard, P. van den; Calkoen, E.; Blom, N.; Kroft, L.; ... ; Roest, A. 2019
Aim: In patients after atrioventricular septal defect correction, altered geometry leads to a changed position and subsequent flow over the left ventricular outflow tract. We hypothesised that this... Show moreAim: In patients after atrioventricular septal defect correction, altered geometry leads to a changed position and subsequent flow over the left ventricular outflow tract. We hypothesised that this altered flow may influence haemodynamics in the ascending aorta. Methods: In total, 30 patients after atrioventricular septal defect correction (age 27.6 +/- 12.8 years) and 28 healthy volunteers (age 24.8 +/- 13.7 years) underwent 4D flow cardiovascular magnetic resonance. Left ventricular ejection fraction and mean and peak wall shear stress calculated at ascending aortic peak systole were obtained from cardiovascular magnetic resonance. Left ventricular outflow tract data including velocity and diameter were obtained from echocardiography. Results: Patients showed a higher mean (911 +/- 173 versus 703 +/- 154 mPa, p = 0.001) and peak ascending aortic wall shear stress (1264 +/- 302 versus 1009 +/- 240 mPa, p = 0.001) compared to healthy volunteers. Increased blood flow velocities over the left ventricular outflow tract (1.49 +/- 0.30 m/s versus 1.22 +/- 0.20 m/s, p < 0.001) correlated well with mean and peak ascending aortic wall shear stress (r = 0.67, p < 0.001 and r = 0.77, p < 0.001). Conclusion: After atrioventricular septal defect correction, increased wall shear stress was observed, which correlated to velocities over the left ventricular outflow tract. These findings imply that altered outflow tract geometry contributes to changed aortic haemodynamics. Show less
Mitral valve (MV) leaflets affect the formation, growth, and decay of vortices in the left ventricle (LV) during diastolic filling. The shape and motion of MV leaflets are simplified in most... Show moreMitral valve (MV) leaflets affect the formation, growth, and decay of vortices in the left ventricle (LV) during diastolic filling. The shape and motion of MV leaflets are simplified in most studies due to computational restrictions. In this study, we present a newly developed mathematical method to model the dynamic movement of valve leaflets and annulus, which is based on in vivo data obtained with magnetic resonance imaging (MRI). In the present method, we solve a boundary value problem where the MV surface is initially unknown. The resultant MV shapes are included in a dynamic motion model of the LV to assess the change of intraventricular flow patterns. To estimate the effects of the MV on left intraventricular flow, a LV model without MV leaflets was also simulated for comparison. Our study showed that the presence of the MV and the shape of its leaflets significantly altered the formation and evolution of vortex structures in the LV. The various MV leaflet shapes accelerate the transvalvular flow distinctly, leading to different formation and development of vortex structures. Show less
Roos, A. de; Grond, J. van der; Mitchell, G.; Westenberg, J. 2017