Background: A decade ago, it became possible to derive mean systemic filling pressure (MSFP) at the bedside using the inspiratory hold maneuver. MSFP has the potential to help guide hemodynamic... Show moreBackground: A decade ago, it became possible to derive mean systemic filling pressure (MSFP) at the bedside using the inspiratory hold maneuver. MSFP has the potential to help guide hemodynamic care, but the estimation is not yet implemented in common clinical practice. In this study, we assessed the ability of MSFP, vascular compliance (Csys), and stressed volume (Vs) to track fluid boluses. Second, we assessed the feasibility of implementation of MSFP in the intensive care unit (ICU). Exploratory, a potential difference in MSFP response between colloids and crystalloids was assessed. Methods: This was a prospective cohort study in adult patients admitted to the ICU after cardiac surgery. The MSFP was determined using 3–4 inspiratory holds with incremental pressures (maximum 35 cm H2O) to construct a venous return curve. Two fluid boluses were administered: 100 and 500 ml, enabling to calculate Vs and Csys. Patients were randomized to crystalloid or colloid fluid administration. Trained ICU consultants acted as study supervisors, and protocol deviations were recorded. Results: A total of 20 patients completed the trial. MSFP was able to track the 500 ml bolus (p < 0.001). In 16 patients (80%), Vs and Csys could be determined. Vs had a median of 2029 ml (IQR 1605–3164), and Csys had a median of 73 ml mmHg−1 (IQR 56–133). A difference in response between crystalloids and colloids was present for the 100 ml fluid bolus (p = 0.019) and in a post hoc analysis, also for the 500 ml bolus (p = 0.010). Conclusion: MSFP can be measured at the bedside and provides insights into the hemodynamic status of a patient that are currently missing. The clinical feasibility of Vs and Csys was judged ambiguously based on the lack of required hemodynamic stability. Future studies should address the clinical obstacles found in this study Show less
Potentially, mean circulatory filling pressure (Pmcf) could aid hemodynamic management in patients admitted to the intensive care unit (ICU). However, data regarding the normal range for Pmcf do... Show morePotentially, mean circulatory filling pressure (Pmcf) could aid hemodynamic management in patients admitted to the intensive care unit (ICU). However, data regarding the normal range for Pmcf do not exist challenging its clinical use. We aimed to define the range for Pmcf for ICU patients and also calculated in what percentage of cases equilibrium between arterial blood pressure (ABP) and central venous pressure (CVP) was reached. In patients in whom no equilibrium was reached, we corrected for arterial-to-venous compliance differences. Finally, we studied the influence of patient characteristics on Pmcf. We hypothesized fluid balance, the use of vasoactive medication, being on mechanical ventilation, and the level of positive endexpiratory pressure would be positively associated with Pmcf. We retrospectively studied a cohort of 311 patients that had cardiac arrest in ICU while having active recording of ABP and CVP 1 min after death. Median Pmcf was 15 mmHg [interquartile range (IQR) 12-18]. ABP and CVP reached an equilibrium state in 52% of the cases. Correction for arterial-to-venous compliances differences resulted in a maximum alteration of 1.3 mmHg in Pmcf. Fluid balance over the last 24 h, the use of vasoactive medication, and being on mechanical ventilation were associated with a higher Pmcf. Median Pmcf was 15 mmHg (IQR 12-18). When ABP remained higher than CVP, correction for arterial-to-venous compliance differences did not result in a clinically relevant alteration of Pmcf. Pmcf was affected by factors known to alter vasomotor tone and effective circulating blood volume.NEW & NOTEWORTHY In a cohort of 311 intensive care unit (ICU) patients, median mean circulatory filling pressure (Pmcf) measured after cardiac arrest was 15 mmHg (interquartile range 12-18). In 48% of cases, arterial blood pressure remained higher than central venous pressure. but correction for arterial-to-venous compliance differences did not result in clinically relevant alterations of Pmcf. Fluid balance, use of vasopressors or inotropes, and being on mechanical ventilation were associated with a higher Pmcf. Show less
BACKGROUND: Although arterial hypotension occurs frequently with propofol use in humans, its effects on intravascular volume and vascular capacitance are uncertain. We hypothesized that propofol... Show moreBACKGROUND: Although arterial hypotension occurs frequently with propofol use in humans, its effects on intravascular volume and vascular capacitance are uncertain. We hypothesized that propofol decreases vascular capacitance and therefore decreases stressed volume.METHODS: Cardiac output (CO) was measured using Modelflow(®) in 17 adult subjects after upper abdominal surgery. Mean systemic filling pressure (MSFP) and vascular resistances were calculated using venous return curves constructed by measuring steady-state arterial and venous pressures and CO during inspiratory hold manoeuvres at increasing plateau pressures. Measurements were performed at three incremental levels of targeted blood propofol concentrations.RESULTS: Mean blood propofol concentrations for the three targeted levels were 3.0, 4.5, and 6.5 µg ml(-1). Mean arterial pressure, central venous pressure, MSFP, venous return pressure, Rv, systemic arterial resistance, and resistance of the systemic circulation decreased, stroke volume variation increased, and CO was not significantly different as propofol concentration increased.CONCLUSIONS: An increase in propofol concentration within the therapeutic range causes a decrease in vascular stressed volume without a change in CO. The absence of an effect of propofol on CO can be explained by the balance between the decrease in effective, or stressed, volume (as determined by MSFP), the decrease in resistance for venous return, and slightly improved heart function.CLINICAL TRIAL REGISTRATION: Netherlands Trial Register: NTR2486. Show less