Objectives The purpose of this study was to assess left atrial (LA) strain during long-term follow-up after catheter ablation for atrial fibrillation and to find predictors for LA reverse... Show moreObjectives The purpose of this study was to assess left atrial (LA) strain during long-term follow-up after catheter ablation for atrial fibrillation and to find predictors for LA reverse remodeling. Background The association between LA reverse remodeling and improvement in LA strain after catheter ablation has not been investigated thus far. Methods In 148 patients undergoing catheter ablation for atrial fibrillation, LA volumes and LA strain were assessed with echocardiography at baseline and after a mean of 13.2 +/- 6.7 months of follow-up. The study population was divided according to LA reverse remodeling at follow-up: responders were defined as patients who exhibited 15% or more reduction in maximum LA volume at long-term follow-up. Left atrial systolic (LAs) strain was assessed with tissue Doppler imaging. Results At follow-up, 93 patients (63%) were classified as responders, whereas 55 patients (37%) were nonresponders. At baseline, LAs strain was significantly higher in the responders as compared with the nonresponders (19 +/- 8% vs. 14 +/- 6%; p = 0.001). Among the responders, a significant increase in LAs strain was noted from baseline to follow-up (from 19 +/- 8% to 22 +/- 9%; p < 0.05), whereas no change was noted among the nonresponders. LAs strain at baseline was an independent predictor of LA reverse remodeling (odds ratio: 1.813; 95% confidence interval: 1.102 to 2.982; p = 0.019). Conclusions In the present study, 63% of the patients exhibited LA reverse remodeling after catheter ablation for atrial fibrillation, with a concomitant improvement in LA strain. LA strain at baseline was an independent predictor of LA reverse remodeling. (J Am Coll Cardiol 2011;57:324-31) (C) 2011 by the American College of Cardiology Foundation Show less
OBJECTIVES The purpose of this study was to assess left atrial (LA) strain during long-term follow-up after catheter ablation for atrial fibrillation and to find predictors for LA reverse... Show moreOBJECTIVES The purpose of this study was to assess left atrial (LA) strain during long-term follow-up after catheter ablation for atrial fibrillation and to find predictors for LA reverse remodeling. BACKGROUND The association between LA reverse remodeling and improvement in LA strain after catheter ablation has not been investigated thus far. METHODS In 148 patients undergoing catheter ablation for atrial fibrillation, LA volumes and LA strain were assessed with echocardiography at baseline and after a mean of 13.2 ± 6.7 months of follow-up. The study population was divided according to LA reverse remodeling at follow-up: responders were defined as patients who exhibited 15% or more reduction in maximum LA volume at long-term follow-up. Left atrial systolic (LAs) strain was assessed with tissue Doppler imaging. RESULTS At follow-up, 93 patients (63%) were classified as responders, whereas 55 patients (37%) were nonresponders. At baseline, LAs strain was significantly higher in the responders as compared with the nonresponders (19 ± 8% vs. 14 ± 6%; p = 0.001). Among the responders, a significant increase in LAs strain was noted from baseline to follow-up (from 19 ± 8% to 22 ± 9%; p < 0.05), whereas no change was noted among the nonresponders. LAs strain at baseline was an independent predictor of LA reverse remodeling (odds ratio: 1.813; 95% confidence interval: 1.102 to 2.982; p = 0.019). CONCLUSIONS In the present study, 63% of the patients exhibited LA reverse remodeling after catheter ablation for atrial fibrillation, with a concomitant improvement in LA strain. LA strain at baseline was an independent predictor of LA reverse remodeling. Show less
Atary, J.Z.; Borleffs, C.J.W.; Bom, J.G. van der; Trines, S.A.I.P.; Bootsma, M.; Zeppenfeld, K.; ... ; Schalij, M.J. 2010
Myocardial excitability is known (amongst other reasons) to be related to the degree of ischaemia, contractile dysfunction and heart failure. It was hypothesized that the right ventricular (RV)... Show moreMyocardial excitability is known (amongst other reasons) to be related to the degree of ischaemia, contractile dysfunction and heart failure. It was hypothesized that the right ventricular (RV) stimulation threshold has prognostic value with respect to the occurrence of ventricular arrhythmias (VAs) and patient survival in recipients of an implantable cardioverter defibrillator (ICD). Ischaemic heart disease patients receiving an ICD at Leiden University Medical Center as primary prevention for sudden cardiac death were included in this study. Right ventricular thresholds were determined at ICD implant. Data were collected on VAs triggering ICD therapy and on all-cause mortality. A total of 689 consecutive patients were included (87% male, age 63 +/- 11 years, left ventricular ejection fraction (LVEF) 29 +/- 11%) and followed for a median of 28 months. Post-implant RV-threshold was 0.7 +/- 0.5 volt (V) at 0.5 ms pulse duration. Best dichotomous separation was reached at a cut-off of 1 V. During follow-up, 167 (24%) patients received appropriate ICD therapy, 88 (13%) had appropriate shocks and 134 (19%) died. Cumulative appropriate shock incidence for patients with RV threshold >= 1 V (n = 166) was 16% at 1 year, 24% at 3 years and 34% at 5 years compared with 4, 11 and 17% for patients with an RV-threshold < 1 V (n = 523). Adjusted hazard ratio of RV threshold >= 1 V was 2.0 (95% CI: 1.4-2.9) for appropriate therapy, 3.3 (95% CI: 2.0-5.4) for appropriate shocks and 1.6 (95% CI: 1.1-2.5) for mortality. The RV stimulation threshold at ICD implant has a strong independent prognostic value for the occurrence of VAs triggering appropriate ICD therapy, appropriate shocks and mortality. Show less