BACKGROUND: Cardiac device infections (CDIs) are a serious complication associated with the implantation of cardiac rhythm devices. However, the effect of CDI on the subsequent risk of mortality is... Show moreBACKGROUND: Cardiac device infections (CDIs) are a serious complication associated with the implantation of cardiac rhythm devices. However, the effect of CDI on the subsequent risk of mortality is unknown. OBJECTIVE: To assess the prognostic importance of CDI in recipients of implantable cardioverter-defibrillator and cardiac resynchronization therapy - defibrillator. METHODS: All patients who received their initial implantable cardioverter-defibrillator/cardiac resynchronization therapy - defibrillator between January 2000 and September 2009 were included. During follow-up, the occurrence of CDI and all-cause mortality were noted. The prognostic importance of the first CDI on mortality was assessed by modeling CDI as a time-dependent covariate in the Cox proportional hazards model. RESULTS: A total of 2476 patients (79% men; mean age 62 ± 13 years) were included in this analysis. During follow-up, CDI occurred in 64 (2.6%) patients. The 1-year mortality following first CDI was 16.9% (95% confidence interval 6.7%-27.1%). Experiencing the first CDI was associated with a 1.9-fold (hazard ratio 1.87; 95% confidence interval 1.07-3.26) increased risk of mortality compared to patients who did not experience CDI. After controlling for possible confounders, this increased to a 2.4-fold (hazard ratio 2.40; 95% confidence interval 1.35-4.28) increased risk of mortality. CONCLUSIONS: In a large cohort of patients who receive implantable cardioverter-defibrillator/cardiac resynchronization therapy - defibrillator after their initial implant, the 3-year incidence of CDI was 2.6%. The occurrence of CDI was associated with substantial 1-year mortality, and patients experiencing CDI had a more than 2-fold increased risk of mortality compared with patients who remained free from CDI. Show less
Gosselink, M.J.; Schenkeveld, K.W.M.; Trines, S.A.; Vliet, I.M. van 2011
Background The presence of atrial fibrillation (AF) is related to increased levels of natriuretic peptides. In addition, increased natriuretic peptide levels are predictive of the development of AF... Show moreBackground The presence of atrial fibrillation (AF) is related to increased levels of natriuretic peptides. In addition, increased natriuretic peptide levels are predictive of the development of AF. However, the role of natriuretic peptides to predict recurrence of AF after radiofrequency catheter ablation (RFCA) is controversial. Objective The study aimed to investigate the role of natriuretic peptides in the prediction of AF recurrence after RFCA for AF. Methods Pre-procedural amino-terminal pro-atrial natriuretic peptide (NT-proANP) and amino-terminal-pro-B-type natriuretic peptide (NT-proBNP) plasma levels were determined in 87 patients undergoing RFCA for symptomatic drug-refractory AF. In addition, a comprehensive clinical and echocardiographic evaluation was performed at baseline. Left atrial volumes, left ventricular volumes, and function (systolic and diastolic) were assessed. During a 6-month follow-up period, AF recurrence was monitored and defined as any registration of AF on electrocardiogram or an episode of AF longer than 30 seconds on 24-hour Holter monitoring. The role of natriuretic peptide plasma levels to predict AF recurrence after RFCA was studied. Results During follow-up, 66 patients (76%) maintained sinus rhythm, whereas 21 patients (24%) had AF recurrence. Patients with AF recurrence had higher baseline natriuretic peptide levels than patients who maintained sinus rhythm (NT-proANP 3.19 nmol/L [2.55-4.28] vs 2.52 nmol/L [1.69-3.55], P = .030; NT-proBNP 156.4 pg/mL [64.1-345.3] vs 84.6 pg/mL [43.3-142.7], P = .036). However, NT-proBNP was an independent predictor of AF recurrence, whereas NT-proANP was not. Moreover, NT-proBNP had an incremental value over echocardiographic characteristics to predict AF recurrence after RFCA. Conclusion Baseline NT-proBNP plasma level is an independent predictor of AF recurrence after RFCA. (Am Heart J 2011;161:197-203.) Show less
Multislice computed tomography (MSCT) is commonly acquired before radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) to plan and guide the procedure. MSCT allows accurate... Show moreMultislice computed tomography (MSCT) is commonly acquired before radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) to plan and guide the procedure. MSCT allows accurate measurement of the left atrial (LA) and pulmonary vein (PV) dimensions and classification of the PV anatomy. The aim of the present study was to investigate the effect of LA dimensions, PV dimensions, and PV anatomy on the outcome of circumferential RFCA for AF. A total of 100 consecutive patients undergoing RFCA for AF (paroxysmal 72%, persistent 28%) were studied. The LA dimensions, PV dimensions, and PV anatomy were evaluated three dimensionally using MSCT. The PV anatomy was classified as normal or atypical according to the absence/presence of a common trunk or additional veins. After a mean follow-up of 11.6 ± 2.8 months, 65 patients (65%) maintained sinus rhythm. The enlargement of the left atrium in the anteroposterior direction on MSCT was related to a greater risk of AF recurrence. No relation was found between the PV dimensions and the outcome of RFCA. In addition, normal right-sided PV anatomy was related to a greater risk of AF recurrence compared to atypical right-sided PV anatomy. Multivariate analysis showed that an anteroposterior LA diameter on MSCT (odds ratio 1.083, p = 0.027) and normal right-sided PV anatomy (odds ratio 6.711, p = 0.006) were independent predictors of AF recurrence after RFCA. In conclusion, enlargement of the anteroposterior LA diameter and the presence of normal anatomy of the right PVs are independent risk factors for AF recurrence. No relation was found between the PV dimensions and outcome of RFCA. Show less
Multislice computed tomography (MSCT) is commonly acquired before radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) to plan and guide the procedure. MSCT allows accurate... Show moreMultislice computed tomography (MSCT) is commonly acquired before radiofrequency catheter ablation (RFCA) for atrial fibrillation (AF) to plan and guide the procedure. MSCT allows accurate measurement of the left atrial (LA) and pulmonary vein (PV) dimensions and classification of the PV anatomy. The aim of the present study was to investigate the effect of LA dimensions, PV dimensions, and PV anatomy on the outcome of circumferential RFCA for AF. A total of 100 consecutive patients undergoing RFCA for AF (paroxysmal 72%, persistent 28%) were studied. The LA dimensions, PV dimensions, and PV anatomy were evaluated three dimensionally using MSCT. The PV anatomy was classified as normal or atypical according to the absence/presence of a common trunk or additional veins. After a mean follow-up of 11.6 +/- 2.8 months, 65 patients (65%) maintained sinus rhythm. The enlargement of the left atrium in the anteroposterior direction on MSCT was related to a greater risk of AF recurrence. No relation was found between the PV dimensions and the outcome of RFCA. In addition, normal right-sided PV anatomy was related to a greater risk of AF recurrence compared to atypical right-sided PV anatomy. Multivariate analysis showed that an anteroposterior LA diameter on MSCT (odds ratio 1.083, p = 0.027) and normal right-sided PV anatomy (odds ratio 6.711, p = 0.006) were independent predictors of AF recurrence after RFCA. In conclusion, enlargement of the anteroposterior LA diameter and the presence of normal anatomy of the right PVs are independent risk factors for AF recurrence. No relation was found between the PV dimensions and outcome of RFCA. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:243-249) Show less
Bie, M.K. de; Fouad, D.; Rees, J.B. van; Borleffs, C.J.; Trines, S.A.; Schalij, M.J.; Erven, L. van 2010