Context: Both thyroid dysfunction and levothyroxine (LT4) therapy have been associated with bone loss, but studies on the effect of LT4 for subclinical hypothyroidism (SHypo) on bone yielded... Show moreContext: Both thyroid dysfunction and levothyroxine (LT4) therapy have been associated with bone loss, but studies on the effect of LT4 for subclinical hypothyroidism (SHypo) on bone yielded conflicting results.Objective: To assess the effect of LT4 treatment on bone mineral density (BMD), Trabecular Bone Score (TBS), and bone turnover markers (BTMs) in older adults with SHypo.Design and Intervention: Planned nested substudy of the double-blind placebo-controlled TRUST trial. Participants with SHypo were randomized to LT4 with dose titration versus placebo with computerized mock titration.Setting and Participants: 196 community-dwelling adults over 65 years enrolled at the Swiss TRUST sites had baseline and 1-year follow-up bone examinations; 4 participants withdrew due to adverse events not related to treatment.Main Outcome Measures: One-year percentage changes of BMD, TBS, and 2 serum BTMs (serum CTX-1 [sCTX] and procollagen type 1 N-terminal polypeptide [P1NP]). Student's t-test for unadjusted analyses and linear regression adjusted for clinical center and sex were performed.Results: Mean age was 74.3 years +/- 5.7, 45.4% were women, and 19.6% were osteoporotic. The unadjusted 1-year change in lumbar spine BMD was similar between LT4 (+0.8%) and placebo-treated groups (-0.6%; between-groups difference +1.4%: 95% confidence interval [CI] -0.1 to 2.9, P = .059). Likewise, there were no between-group differences in 1-year change in TBS (-1.3%: 95% CI -3.1 to 0.6, P = .19), total hip BMD (-0.2%: 95% CI -1.1 to 0.1, P = .61), or BTMs levels (sCTX +24.1%: 95% CI -7.9 to 56.2, P = .14), or after adjustment for clinical centers and sex.Conclusions: Over 1-year levothyroxine had no effect on bone health in older adults with SHypo. Show less
Brandts, A.; Westenberg, J.J.M.; Elderen, S.G.C. van; Kroft, L.J.M.; Roes, S.D.; Tamsma, J.T.; ... ; Roos, A. de 2013
Purpose: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T... Show morePurpose: To objectively compare quantitative parameters related to image quality attained at coronary magnetic resonance (MR) angiography of the right coronary artery (RCA) performed at 7 T and 3 T. Materials and Methods: Institutional review board approval was obtained, and volunteers provided signed informed consent. Ten healthy adult volunteers (mean age +/- standard deviation, 25 years +/- 4; seven men, three women) underwent navigator-gated three-dimensional MR angiography of the RCA at 7 T and 3 T. For 7 T, a custom-built quadrature radiofrequency transmit-receive surface coil was used. At 3 T, a commercial body radiofrequency transmit coil and a cardiac coil array for signal reception were used. Segmented k-space gradient-echo imaging with spectrally selective adiabatic fat suppression was performed, and imaging parameters were similar at both field strengths. Contrast-to-noise ratio between blood and epicardial fat; signal-to-noise ratio of the blood pool; RCA vessel sharpness, diameter, and length; and navigator efficiency were quantified at both field strengths and compared by using a Mann-Whitney U test. Results: The contrast-to-noise ratio between blood and epicardial fat was significantly improved at 7 T when compared with that at 3 T (87 +/- 34 versus 52 +/- 13; P = .01). Signal-to-noise ratio of the blood pool was increased at 7 T (109 6 47 versus 67 +/- 19; P = .02). Vessel sharpness obtained at 7 T was also higher (58% +/- 9 versus 50% +/- 5; P = .04). At the same time, RCA vessel diameter and length and navigator efficiency showed no significant field strength-dependent difference. Conclusion: In our quantitative and qualitative study comparing in vivo human imaging of the RCA at 7 T and 3 T in young healthy volunteers, parameters related to image quality attained at 7 T equal or surpass those from 3 T. (C) RSNA, 2010 Show less
Brandts, A.; Roes, S.D.; Doornbos, J.; Weiss, R.G.; Roos, A. de; Stuber, M.; Westenberg, J.J.M. 2010
Purpose: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space... Show morePurpose: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. Materials and Methods: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). Results: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. Conclusion: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity. Show less
Brandts, A.; Roes, S.D.; Doornbos, J.; Weiss, R.G.; Roos, A. de; Stuber, M.; Westenberg, J.J.M. 2010
PURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space... Show morePURPOSE: To evaluate accuracy and reproducibility of flow velocity and volume measurements in a phantom and in human coronary arteries using breathhold velocity-encoded (VE) MRI with spiral k-space sampling at 3 Tesla. MATERIALS AND METHODS: Flow velocity assessment was performed using VE MRI with spiral k-space sampling. Accuracy of VE MRI was tested in vitro at five constant flow rates. Reproducibility was investigated in 19 healthy subjects (mean age 25.4 +/- 1.2 years, 11 men) by repeated acquisition in the right coronary artery (RCA). RESULTS: MRI-measured flow rates correlated strongly with volumetric collection (Pearson correlation r = 0.99; P < 0.01). Due to limited sample resolution, VE MRI overestimated the flow rate by 47% on average when nonconstricted region-of-interest segmentation was used. Using constricted region-of-interest segmentation with lumen size equal to ground-truth luminal size, less than 13% error in flow rate was found. In vivo RCA flow velocity assessment was successful in 82% of the applied studies. High interscan, intra- and inter-observer agreement was found for almost all indices describing coronary flow velocity. Reproducibility for repeated acquisitions varied by less than 16% for peak velocity values and by less than 24% for flow volumes. CONCLUSION: 3T breathhold VE MRI with spiral k-space sampling enables accurate and reproducible assessment of RCA flow velocity. Show less