Objectives This study aimed to determine the effect of bariatric surgery-induced weight loss on bone marrow adipose tissue (BMAT) and bone mineral density (BMD) in postmenopausal, nondiabetic women... Show moreObjectives This study aimed to determine the effect of bariatric surgery-induced weight loss on bone marrow adipose tissue (BMAT) and bone mineral density (BMD) in postmenopausal, nondiabetic women.Methods A total of 14 postmenopausal, nondiabetic women with obesity who were scheduled for laparoscopic Roux-en-Y gastric bypass surgery (RYGB) were included in this study. Vertebral bone marrow fat signal fraction was determined by quantitative chemical shift magnetic resonance imaging, and vertebral volumetric BMD (vBMD) was determined by quantitative computed tomography before surgery and 3 and 12 months after surgery. Data were analyzed by linear mixed model.Results Body weight [mean (SD)] decreased after surgery from 108 (13) kg at baseline to 89 (12) kg at 3 months and 74 (11) kg at 12 months (P < 0.001). BMAT decreased after surgery from 51% (8%) at baseline to 50% (8%) at 3 months and 46% (7%) at 12 months (P = 0.004). vBMD decreased after surgery from 101 (26) mg/cm(3) at baseline to 94 (28) mg/cm(3) at 3 months (P = 0.003) and 94 (28) mg/cm(3) at 12 months (P = 0.035). Changes in BMAT and vBMD were not correlated (rho = -0.10 and P = 0.75). Calcium and vitamin D concentrations did not change after surgery.Conclusions RYGB decreases both BMAT (after 12 months) and vBMD (both after 3 months and 12 months) in postmenopausal, nondiabetic women. Changes in BMAT and vBMD were not correlated. These findings suggest that BMAT does not contribute to bone loss following RYGB. Show less
AIMS: The aim of this study was to assess in vitro the diagnostic accuracy of computed tomography angiography (CTA) for the evaluation of complex coronary lesions.METHODS AND RESULTS: Five... Show moreAIMS: The aim of this study was to assess in vitro the diagnostic accuracy of computed tomography angiography (CTA) for the evaluation of complex coronary lesions.METHODS AND RESULTS: Five Plexiglas phantoms with three bifurcation lesions each were designed to mimic the anatomic variations and fractal phenomena of the coronary tree. In addition, luminal stenoses were scaled up with increases of 10% from 40% to 80%, corresponding to luminal areas ranging from 3.0 mm2 to 0.22 mm2. Third-generation dual-source computed tomography was used. Automated quantitative CTA analysis was performed according to the bifurcation segment model. The primary objective was to determine the diagnostic accuracy of quantitative CTA in assessing bifurcation lesions with the phantoms as a reference. The accuracy of CTA for the assessment of minimal luminal diameter was -0.07 mm (limits of agreement -0.75 to 0.61), for reference vessel diameter 0.19 mm (limits of agreement -0.25 to 0.63) and diameter stenosis 8.2% (limits of agreement -13.2 to 29.5) with no difference regarding the location within the bifurcation (i.e., proximal and distal main vessel and side branch). In stenosis with minimal luminal diameter <= 1 mm, CTA overestimated the lesion severity (bias 0.19 mm, limits of agreement -0.09 to 0.47), whereas in lesions with severe stenosis and minimal luminal diameter >= 1 mm, CTA underestimated the lesion severity (bias -0.48 mm, limits of agreement -0.55 to -0.41). CTA was able to identify the contrast-filled lumen in all degrees of lesion severity.CONCLUSIONS: In vitro, CTA is accurate for the evaluation of bifurcation lesions. CTA was able to distinguish contrast-filled lumen even in severe obstructive lesions. These findings require further validation in the clinical setting. Show less
Lier, M.G.J.T.B. van; Lopriore, E.; Vandenbussche, F.P.H.A.; Streekstra, G.J.; Siebes, M.; Nikkels, P.G.J.; ... ; Wijngaard, J.P.H.M. van den 2016