OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients.METHODS: A prospective, EU-funded, single-arm, multicentre study... Show moreOBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients.METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement.RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9–55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6mm (standard deviation 2.4). The median operation duration was 312min (IQR 234–417), the median cardiopulmonary bypass time was 154min (IQR 118–212) and the median cross-clamp time 121min (IQR 93–150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5h postoperation. There were 3 late deaths, 1 death due to endocarditis 4months postoperatively and 2 unrelated deaths after 5 and 7years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9years [IQR 5.1–6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0mmHg (IQR 7.8–17.6) and regurgitation of median 0.5 (IQR 0–0.5) of grade 0–3 were excellent. At 5years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively.CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics. Show less
Zeppenfeld, K.; Tfelt-Hansen, J.; Riva, M. de; Winkel, B.G.; Behr, E.R.; Blom, N.A.; ... ; ESC Scientific Document Group 2022
Aims The aim of this study is to analyse how current recommendations on left ventricular (LV) diastolic function assessment have been adopted. Identifying potential discrepancies between... Show moreAims The aim of this study is to analyse how current recommendations on left ventricular (LV) diastolic function assessment have been adopted. Identifying potential discrepancies between recommendations and everyday clinical practice would enable us to better understand and address the remaining challenges in this controversial and complex field.Methods and results A total of 93 centres, mainly from tertiary care settings, responded to the survey. More than three-quarters (77%) of centres follow the 2016 ASE/EACVI recommendations for LV diastolic function evaluation in patients with preserved ejection fraction based upon e, E/e', tricuspid regurgitation velocity, and left atrial (LA) volume. These recommendations were generally preferred to the previous 2009 version. Many centres also consider strain assessments in the LV (48%) and left atrium (53%) as well as diastolic stress echocardiography (33%) to be useful as additional assessments of LV diastolic function. Echocardiographic assessments of LV diastolic function were used frequently to guide therapy in 72% of centres.Conclusion There is widespread adoption of current recommendation on the evaluation of LV diastolic function and these are frequently used to guide patient management. Many centres now also consider LV and LA strain assessments useful in the clinical assessment of diastolic function. These may be considered in future recommendations. Show less
This International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type,... Show moreThis International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type, with 3 phenotypes: right-left cusp fusion, right-non cusp fusion and left-non cusp fusion; 2. 2-sinus type with 2 phenotypes: Latero-lateral and antero-posterior; and 3. Partial-fusion or forme fruste. This consensus recognizes 3 bicuspid-aortopathy types: 1. Ascending phenotype; root phenotype; and 3. extended phenotypes. (Ann Thorac Surg 2021;112:1005-22) 2021 Jointly between The Society of Thoracic Surgeons, the American Association for Thoracic Surgery, the European Association for Cardio-Thoracic Surgery, and the Radiological Society of North America. Published by Elsevier Inc. Show less
This International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type,... Show moreThis International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type, with 3 phenotypes: right-left cusp fusion, right-non cusp fusion and left-non cusp fusion; 2. 2-sinus type with 2 phenotypes: Latero-lateral and antero-posterior; and 3. Partial-fusion or forme fruste. This consensus recognizes 3 bicuspid-aortopathy types: 1. Ascending phenotype; root phenotype; and 3. extended phenotypes. Show less
This International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type,... Show moreThis International evidence-based nomenclature and classification consensus on the congenital bicuspid aortic valve and its aortopathy recognizes 3 types of bicuspid aortic valve: 1. Fused type, with 3 phenotypes: right-left cusp fusion, right-non cusp fusion and left-non cusp fusion; 2. 2-sinus type with 2 phenotypes: Latero-lateral and antero-posterior; and 3. Partial-fusion or forme fruste. This consensus recognizes 3 bicuspid-aortopathy types: 1. Ascending phenotype; root phenotype; and 3. extended phenotypes. Show less
This International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion,... Show moreThis International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non-coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phe Show less
This International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion,... Show moreThis International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phenotypes. (Ann Thorac Surg 2021;112:e203-35) 2021 Jointly between The Society of Thoracic Surgeons, the American Association for Thoracic Surgery, the European Association for Cardio-Thoracic Surgery, and the Radiological Society of North America. Published by Elsevier Inc. Show less
This International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion,... Show moreThis International Consensus Classification and Nomenclature for the congenital bicuspid aortic valve condition recognizes 3 types of bicuspid valves: 1. The fused type (right-left cusp fusion, right-non-coronary cusp fusion and left-non-coronary cusp fusion phenotypes); 2. The 2-sinus type (latero-lateral and antero-posterior phenotypes); and 3. The partial-fusion (forme fruste) type. The presence of raphe and the symmetry of the fused type phenotypes are critical aspects to describe. The International Consensus also recognizes 3 types of bicuspid valve-associated aortopathy: 1. The ascending phenotype; 2. The root phenotype; and 3. Extended phenotypes. Show less
Early and late cardiovascular (CV) toxicities related to many cancer treatments may complicate the clinical course of patients, offsetting therapeutic benefits, and altering prognosis. The early... Show moreEarly and late cardiovascular (CV) toxicities related to many cancer treatments may complicate the clinical course of patients, offsetting therapeutic benefits, and altering prognosis. The early detection, monitoring, and treatment of cardiotoxicity have therefore become essential parts of cancer patient care. CV imaging is a cornerstone of every cardio-oncology unit, but its use may vary across Europe because of the non-uniform availability of advanced imaging techniques and differences in the organization and logistics of cardio-oncology services. The purpose of this EACVI survey in cardio-oncology is to obtain real-world data on the current usage of cardiac imaging in cancer patients. Data from 104 centres and 35 different countries confirmed that cardiac imaging plays a pivotal role in the detection and monitoring of cardiac toxicity in oncology patients in Europe and beyond. However, it also revealed gaps between guidelines recommendations and everyday clinical practice, highlighting some of the challenges that need to be overcome in this rapidly advancing field. Show less
Horke, A.; Tudorache, I.; Laufer, G.; Andreas, M.; Pomar, J.L.; Pereda, D.; ... ; Sarikouch, S. 2020
OBJECTIVES: Decellularized aortic homografts (DAH) may provide an additional aortic valve replacement option for young patients due to their potential to overcome the high early failure rate of... Show moreOBJECTIVES: Decellularized aortic homografts (DAH) may provide an additional aortic valve replacement option for young patients due to their potential to overcome the high early failure rate of conventional allogenic and xenogenic aortic valve prostheses.METHODS: A prospective, European Union-funded, single-arm, multicentre, safety study was conducted in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement.RESULTS: One hundred and forty-four patients (99 male) were prospectively enrolled between October 2015 and October 2018, mean age 33.6 +/- 20.8 years; 45% had undergone previous cardiac operations. Mean implanted DAH diameter 22.6 +/- 2.4 mm and mean durations for the operation, cardiopulmonary bypass and cross-clamp were 341 +/- 140, 174 +/- 80 and 126 +/- 43 min, respectively. There were 2 early deaths (1 LCA thrombus on day 3 and 1 ventricular arrhythmia 5 h postop) and 1 late death due to endocarditis 4 months postoperatively, resulting in a total mortality of 2.08%. One pacemaker implantation was necessary and 1 DAH was successfully repaired after 6 weeks for early regurgitation following subcoronary implantation. All other DAH were implanted as a free-standing root. After a mean follow-up of 1.54 +/- 0.81 years, the primary efficacy end points peak gradient (mean 11.8 +/- 7.5 mmHg) and regurgitation (mean 0.42 +/- 0.49, grade 0-3) were excellent. At 2.5 years, freedom from explantation/endocarditis/bleeding/stroke was 98.4 +/- 1.1%/99.4 +/- 0.6%/99.1 +/- 0.9%/99.2 +/- 0.8%, respectively, with results almost identical to those in an age-matched Ross operation cohort of 212 patients (mean age 34 years) despite DAH patients having undergone >2x more previous procedures.CONCLUSIONS: The initial results of the prospective multicentre ARISE trial show DAH to be safe for aortic valve replacement with excellent haemodynamics in the short follow-up period. Show less
Marsan, N.A.; Michalski, B.; Cameli, M.; Podlesnikar, T.; Manka, R.; Sitges, M.; ... ; Haugaa, K.H. 2020
Aims To evaluate standard reporting of cardiac chambers size and function by transthoracic echocardiography (TTE), the EACVI Scientific Initiatives Committee performed a survey across European... Show moreAims To evaluate standard reporting of cardiac chambers size and function by transthoracic echocardiography (TTE), the EACVI Scientific Initiatives Committee performed a survey across European centres. In particular, the routine use of three-dimensional echocardiography (3DE) and speckle tracking-derived myocardial deformation imaging (STE) was explored.Methods and results A total of 96 European Echocardiography Laboratories from 22 different countries responded to the survey, which consisted of 20 questions. For most of the standard parameters of cardiac chamber size and function, answers from the centres were homogeneous and demonstrated good adherence to current recommendations. In particular, all centres assessed left ventricular (LV) and left atrial (LA) size combining diameter measurements with volumes obtained using the bi-plane Simpson's method. More variability was observed in the measurements of the right heart chambers and thoracic aorta. Interestingly, >90% of centres had access to 3DE and STE; however, the large majority of centres reserved the use of these techniques for selected cases, particularly for the measure of 3D LV volumes and ejection fraction and global longitudinal strain in patients being considered for cardiac device implantation, surgical intervention (valvular heart disease) or screened for cardiotoxicity. Only 10% of centres used 3DE for right ventricular and LA volumes. Also, <30% of the centres used LA strain imaging.Conclusion In Europe, a good adherence to current recommendations was observed for most of the standard parameters of cardiac chambers quantification by TTE. Advanced echocardiography modalities, such as 3DE and STE, are widely available but used only in selected cases. Show less
One of the missions of the European Association of Cardiovascular Imaging (EACVI) is 'to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular... Show moreOne of the missions of the European Association of Cardiovascular Imaging (EACVI) is 'to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular imaging'. The future of imaging involves multimodality so each imager should have the incentive and the possibility to improve its knowledge in other cardiovascular techniques. This article presents the results of a 20 questions survey carried out in cardiovascular imaging (CVI) centres across Europe. The aim of the survey was to assess the situation of experience and training of CVI in Europe, the availability and organization of modalities in each centre and to ask for vision about potential improvements in CVI at national and European level. Show less
Haugaa, K.H.; Marsan, N.A.; Cameli, M.; D'Andrea, A.; Dweck, M.R.; Carvalho, R.F.; ... ; Edvardsen, T. 2019
The European Association of Cardiovascular Imaging (EACVI) is committed to maintaining the highest standards of professional excellence in all aspects of cardiovascular imaging. The mission of the... Show moreThe European Association of Cardiovascular Imaging (EACVI) is committed to maintaining the highest standards of professional excellence in all aspects of cardiovascular imaging. The mission of the EACVI is to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular imaging with a particular focus on education, training, scientific initiatives, and research. The EACVI established the Scientific Initiatives Committee (SIC) in December 2018. This committee has responsibility for surveys among imagers, patients' surveys and surveys including data from clinical practice. The current document describes the aims of the EACVI SIC and the creation of the international EACVI survey network. This document summarizes the EACVI's standards for the survey questions and standards for writing the papers with the results of the surveys. These are in accordance with previous recommendations and were approved by the EACVI SIC and the EACVI Board in 2019. Show less