Background: Misinterpretation of patient preferences in perioperative education can lead to an undesired treatment decision. This explorative interview study presents differences in perspectives of... Show moreBackground: Misinterpretation of patient preferences in perioperative education can lead to an undesired treatment decision. This explorative interview study presents differences in perspectives of patients and professionals on patient education in complex endovascular aortic aneurysm management.Methods: Using convenience sampling, a cross-sectional interview study was performed among patients who were in various stages of the decision-making process for complex endovascular aortic repair. Five physicians were interviewed, representing the main providers of clinical information. Interviews were transcribed verbatim and analyzed inductively.Results: Twelve patients (mean age 76.6 [standard deviation: 6.4], 83% male) were interviewed. Ten (83%) felt like they had no other realistic option besides undergoing surgery, whereas all professionals (5/5) stressed the importance of delicate patient selection. Five patients out of 10 (50%) who commented on their preferred decisional role considered the professional's advice as decisive. All but 1 patient (11/12) reported that the information was easy to understand, whereas 4 out of 5 professionals (80%) doubted whether patients could fully comprehend everything. Patients experienced a lack of information on the recovery process, although professionals stated that this was addressed during consultation.Conclusions: Several differences were found in the perspectives of patients and professionals on education in complex aortic aneurysm management. In order to optimize patient involvement in decision-making, professionals should be aware of these possible discrepancies and address them during consultation. Future research could focus on these differences in more detail by including more patients depending on their treatment and decision stages. Show less
Bulder, R.M.A.; Vorst, J.R. van der; Schaik, J. van; Bedene, A.; Lijfering, W.M.; Bastiaannet, E.; ... ; Lindeman, J.H.N. 2023
Objective:The aim of this time-trend analysis is to estimate long-term excess mortality and associated cardiovascular risk for abdominal aortic aneurysm (AAA) patients after elective repair while... Show moreObjective:The aim of this time-trend analysis is to estimate long-term excess mortality and associated cardiovascular risk for abdominal aortic aneurysm (AAA) patients after elective repair while addressing the changes in AAA management and patient selection over time.Background:Despite the intensification of endovascular aneurysm repair and cardiovascular risk management, Swedish population data suggest that AAA patients retain a persistently high long-term mortality after elective repair. The question is whether this reflects suboptimal treatment, a changing patient population over time, or a national phenomenon.Methods:Nationwide time-trend analysis including 40,730 patients (87% men) following elective AAA repair between 1995 and 2017. Three timeframes were compared, each reflecting changes in the use of endovascular aneurysm repair and intensification of cardiovascular risk management. Relative survival analyses were used to estimate disease-specific excess mortality. Competing risk of death analysis evaluated the risk of cardiovascular versus noncardiovascular death. Sensitivity analysis evaluated the impact of changes in patient selection over time.Results:Short-term excess mortality significantly improved over time. Long-term excess mortality remained high with a doubled mortality risk for women (relative excess risk=1.87, 95% CI: 1.73-2.02). Excess mortality did not differ between age categories. The risk of cardiovascular versus noncardiovascular death remained similar over time, with a higher risk of cardiovascular death for women. Changes in patient population (ie, older and more comorbid patients in the latter period) marginally impacted excess mortality (2%).Conclusions:Despite changes in AAA care, patients retain a high long-term excess mortality after elective repair with a persistent high cardiovascular mortality risk. In this, a clear sex - but no age - disparity stands out. Show less
Rijn, K. van; Schepers, A.; Meer, R.W. van der; Rijswijk, C.S.P. van; Schaik, J. van; Vorst, J.R. van der 2023
A 27-year-old man underwent thoracic endovascular aortic repair for blunt thoracic aortic injury. Fourteen months later, he presented with intermittent paraplegia, congestive heart failure, and a... Show moreA 27-year-old man underwent thoracic endovascular aortic repair for blunt thoracic aortic injury. Fourteen months later, he presented with intermittent paraplegia, congestive heart failure, and a decline of kidney function as a result of high-grade aortic stenosis caused by in-stent thrombosis. He had a concurrent infection with coronavirus disease 2019. The patient was successfully treated using axillofemoral bypass, followed by stent relining 2 weeks later. The possible risk factors and the optimal therapeutic approach for in-stent thrombosis remain unknown, because only a limited number of cases describing this rare complication have been reported. (J Vasc Surg Cases Innov Tech 2023;9:101297.) Show less
Verhagen, M.; Eefting, D.; Rijswijk, C. van; Meer, R. van der; Hamming, J.; Vorst, J. van der; Schaik, J. van 2023
Purpose: Perioperative risk assessments for complex aneurysms are based on the anatomical extent of the aneurysm and do not take the length of the aortic exclusion into account, as it was developed... Show morePurpose: Perioperative risk assessments for complex aneurysms are based on the anatomical extent of the aneurysm and do not take the length of the aortic exclusion into account, as it was developed for open repair. Nevertheless, in the endovascular repair (ER) of complex aortic aneurysms, additional segments of healthy aorta are excluded compared with open repair (OR). The aim of this study was to assess differences in aortic exclusion between the ER and OR of complex aortic aneurysms, to subsequently assess the current classification for complex aneurysm repair. Methods: This retrospective observational study included patients that underwent complex endovascular aortic aneurysm repair by means of fenestrated endovascular aneurysm repair (FEVAR), fenestrated and branched EVAR (FBEVAR), or branched EVAR (BEVAR). The length of aortic exclusion and the number of patent segmental arteries were determined and compared per case in ER and hypothetical OR, using a Wilcoxon signed-rank test. Results: A total of 71 patients were included, who were treated with FEVAR (n = 44), FBEVAR (n = 8), or BEVAR (n = 19) for Crawford types I (n = 5), II (n = 7), III (n = 6), IV (n = 7), and V (n = 2) thoracoabdominal or juxtarenal (n = 44) aneurysms. There was a significant increase in the median exclusion of types I, II, III, IV, and juxtarenal aneurysms (p < 0.05) in ER, compared with hypothetical OR. The number of patent segmental arteries in the ER of type I-IV and juxtarenal aneurysms was significantly lower than in hypothetical OR (p < 0.05). Conclusion: There are significant differences in the length of aortic exclusion between ER and hypothetical OR, with the increased exclusion in ER resulting in a lower number of patent segmental arteries. The ER and OR of complex aortic aneurysms should be regarded as distinct modalities, and as each approach deserves a particular risk assessment, future efforts should focus on reporting on the extent of exclusion per treatment modality, to allow for appropriate comparison. Show less
Tange, F.P.; Hoven, P. van den; Schaik, J. van; Schepers, A.; Bogt, K.E.A. van der; Rijswijk, C.S.P. van; ... ; Vorst, J.R. van der 2023
Contemporary quality control methods are often insufficient in predicting clinical outcomes after revascularization in lower extremity arterial disease (LEAD) patients. This study evaluates the... Show moreContemporary quality control methods are often insufficient in predicting clinical outcomes after revascularization in lower extremity arterial disease (LEAD) patients. This study evaluates the potential of near-infrared fluorescence imaging with indocyanine green to predict the clinical outcome following revascularization. Near-infrared fluorescence imaging was performed before and within 5 days following the revascularization procedure. Clinical improvement was defined as substantial improvement of pain free walking distance, reduction of rest- and/or nocturnal pain, or tendency toward wound healing. Time-intensity curves and 8 perfusion parameters were extracted from the dorsum of the treated foot. The quantified postinterventional perfusion improvement was compared within the clinical outcome groups. Successful near-infrared fluorescence imaging was performed in 72 patients (76 limbs, 52.6% claudication, 47.4% chronic limb-threatening ischemia) including 40 endovascular- and 36 surgical/hybrid revascularizations. Clinical improvement was observed in 61 patients. All perfusion parameters showed a significant postinterventional difference in the clinical improvement group (P-values <.001), while no significant differences were seen in the group without clinical improvement (P-values .168-.929). Four parameters demonstrated significant differences in percentage improvement comparing the outcome groups (P-values within .002-.006). Near-infrared fluorescence imaging has promising additional value besides clinical parameters for predicting the clinical outcome of revascularized LEAD patients. Show less
Tange, F.P.; Ferrari, B.R.; Hoven, P. van den; Schaik, J. van; Schepers, A.; Rijswijk, C.S.P. van; ... ; Vorst, J.R. van der 2023
Background: The angiosome concept is defined as the anatomical territory of a source artery within all tissue layers. When applying this theory in vascular surgery, direct revascularization (DR) is... Show moreBackground: The angiosome concept is defined as the anatomical territory of a source artery within all tissue layers. When applying this theory in vascular surgery, direct revascularization (DR) is preferred to achieve increased blood flow toward the targeted angiosome of the foot in patients with lower extremity arterial disease (LEAD). This study evaluates the applicability of the angiosome concept using quantified near-infrared (NIR) fluorescence imaging with indocMethods: This study included patients undergoing an endovascular- or surgical revascularization of the leg between January 2019 and December 2021. Preinterventional and postinterventional ICG NIR fluorescence imaging was performed. Three angiosomes on the dorsum of the foot were determined: the posterior tibial artery (hallux), the anterior tibial artery (dorsum of the foot) and the combined angiosome (second to fifth digit). The angiosomes were classified from the electronic patient records and the degree of collateralization was classified based on preprocedural computed tomography angiography and/or X-ray angiography. Fluorescence intensity was quantified in all angiosomes. A subgroup analysis based on endovascular or surgical revascularized angiosomes, and within critical limb threatening ischemia (CLTI) patients was performed. Results: ICG NIR fluorescence measurements were obtained in 52 patients (54 limbs) including a total of 157 angiosomes (121 DR and 36 indirect revascularizations [IR]). A significant improvement of all perfusion parameters in both the directly and indirectly revascularized angiosomes was found (P-values between <0.001e0.007). Within the indirectly revascularized angiosomes, 90.6% of the scored collaterals were classified as significant. When comparing the percentual change in perfusion parameters between the directly and indirectly revascularized angiosomes, no significant difference was seen in all perfusion parameters (P-values between 0.253 and 0.881). Similar results were shown in the CLTI patients subgroup analysis, displaying a significant improvement of perfusion parameters in both the direct and indirect angiosome groups (P-values between <0.001 and 0.007), and no significant difference when comparing the percentual parameter improvement between both angiosome groups (P-values between 0.134 and 0.359). Furthermore, no significant differences were observed when comparing Show less
Warmerdam, B.W.C.M.; Stevens, M.; Rijswijk, C.S.P. van; Eefting, D.; Meer, R.W. van der; Putter, H.; ... ; Schaik, J. van 2023
Background: When introducing new techniques, attention must be paid to learning curve. Be-sides quantitative outcomes, qualitative factors of influence should be taken into consideration. This... Show moreBackground: When introducing new techniques, attention must be paid to learning curve. Be-sides quantitative outcomes, qualitative factors of influence should be taken into consideration. This retrospective cohort study describes the quantitative learning curve of complex endovascu-lar aortic repair (EVAR) in a nonhigh-volume academic center and provides qualitative factors that were perceived as contributors to this learning curve. With these factors, we aim to aid in future implementation of new techniques. Methods: All patients undergoing complex EVAR in the Leiden University Medical Center (LUMC) between July 2013 and April 2021 were included (n = 90). Quantitative outcomes were as follows: operating time, blood loss, volume of contrast, hospital stay, major adverse events (MAE), 30-day mortality, and complexity. Patients were divided into 3 temporal groups (n = 30) for dichotomous outcomes. Regression plots were used for continuous outcomes. In 2017, the treatment team was interviewed by an external researcher. These interviews were reanalyzed for factors that contributed to successful implementation. Results: Length of hospital stay (P = 0.008) and operating time (P = 0.010) decreased signif-icantly over time. Fewer cardiac complications occurred in the third group (3: 0% vs. 2: 17% vs. 1: 17%, P = 0.042). There was a trend of increasing complexity (P = 0.076) and number of fen-estrations (P = 0.060). No significant changes occurred in MAE and 30-day mortality. Qualitative factors that, according to the interviewees, positively influenced the learning curve were as fol-lows: communication, mutual trust, a shared sense of responsibility and collective goals, clear authoritative structures, mutual learning, and team capabilities. Conclusions: In addition to factors previously identified in the literature, new learning curve factors were found (mutual learning and shared goals in the operating room (OR)) that should be taken into account when implementing new techniques. Show less
Verhagen, M.J.; Vos, M.S. de; Schaik, J. van; Vorst, J.R. van der; Schepers, A.; Mheen, P.J.M. van de; Hamming, J.F. 2023
Morbidity and mortality (M&M) conferences are an acclaimed method for achieving case-based learning and improving surgical care1. Their educational value is acknowledged, but whether these... Show moreMorbidity and mortality (M&M) conferences are an acclaimed method for achieving case-based learning and improving surgical care1. Their educational value is acknowledged, but whether these conferences contribute to systemic improvement is unclear2. M&M formats vary widely3,4, and are mostly focused on severe adverse events and individual performance, thus lacking consideration of system-level issues or similar cases where successful outcomes were achieved3,5,6. To overcome these shortcomings, an adapted weekly M&M meeting was developed at the authors unit7. In the adapted meeting, the surgical team collectively reflects both on all recently discharged but also on planned procedures, which is consistent with existing frameworks8. Discussing all cases also directs attention to successful outcomes, rather than only the complicated ones. This allows the team to understand how to ensure safety for their patients continuously9,10.The aim of this qualitative study was to investigate how the novel weekly reflective team meeting affects the dynamics of a surgical team and improves the quality of care. Show less
Genderen, O.S. van; Wissen, R.C. van; Hamming, J.F.; Schaik, J. van; Vorst, J.R. van der 2023
Purpose: To describe the concept of aortic elastic deformation (ED) measurement using duplex ultrasonography (DUS) as a tool for detection of high aneurysm sac pressure following endovascular... Show morePurpose: To describe the concept of aortic elastic deformation (ED) measurement using duplex ultrasonography (DUS) as a tool for detection of high aneurysm sac pressure following endovascular aortic repair (EVAR). Technique: High aneurysm sac pressure, with or without proven endoleak, will result in a less compressible aneurysm. Using the dual image function in B-mode of the DUS device and a standardized amount of applied probe pressure, ED can be measured. It is defined as the percentage of deformation of the aneurysm sac on probe pressure application. We hypothesize that less ED of the aneurysm sac can be related with high aneurysm sac pressure and possibly the presence of clinically relevant endoleak. In this note, we describe the technical details of the procedure and report on the applicability and results of ED measurements in the framework of aortic aneurysm and EVAR follow-up in a cohort of 109 patients. Conclusion: ED measurement is the first noninvasive pressure-based method in the quest to find a practical and reliable diagnostic tool to exclude high aneurysm sac pressure. In our patient cohort, patients with proven endoleak showed a smaller ED (less compressible), implying the presence of high aneurysm sac pressure. Further research should confirm whether ED measurement using DUS could reliably exclude endoleak after EVAR and further explore its potential for clinical application in EVAR follow-up. Clinical Impact For the first time, a simple, fast, and inexpensive diagnostic tool is presented in this study for detecting high sac pressure following EVAR. High sac pressure is typically caused by clinically significant endoleaks, which can have significant consequences. Currently, computed tomography scanning is the most common method used to identify and characterize endoleaks. However, measuring elastic deformation may potentially replace more invasive and expensive modalities, such as the computed tomography in the future. Show less
Objective: We evaluate nationwide perioperative outcomes of complex EVAR and assess the volume-outcome association of complex EVAR.Summary of Background Data: Endovascular treatment with... Show moreObjective: We evaluate nationwide perioperative outcomes of complex EVAR and assess the volume-outcome association of complex EVAR.Summary of Background Data: Endovascular treatment with fenestrated (FEVAR) or branched (BEVAR) endografts is progressively used for excluding complex aortic aneurysms (complex AAs). It is unclear if a volumeoutcome association exists in endovascular treatment of complex AAs (complex EVAR).Methods: All patients prospectively registered in the Dutch Surgical Aneurysm Audit who underwent complex EVAR (FEVAR or BEVAR) between January 2016 and January 2020 were included. The effect of annual hospital volume on perioperative mortality was examined using multivariable logistic regression analyses. Patients were stratified into quartiles based on annual hospital volume to determine hospital volume categories.Results: We included 694 patients (539 FEVAR patients, 155 BEVAR patients). Perioperative mortality following FEVAR was 4.5% and 5.2% following BEVAR. Postoperative complication rates were 30.1% and 48.7%, respectively. The first quartile hospitals performed <9 procedures/yr; second, third, and fourth quartile hospitals performed 9-12, 13-22, and >= 23 procedures/yr. The highest volume hospitals treated significantly more complex patients. Perioperative mortality of complex EVAR was 9.1% in hospitals with a volume of <9, and 2.5% in hospitals with a volume of >= 13 (P = 0.008). After adjustment for confounders, an annual volume of >= 13 was associated with less perioperative mortality compared to hospitals with a volume of <9.Conclusions: Data from this nationwide mandatory quality registry shows a significant effect of hospital volume on perioperative mortality following complex EVAR, with high volume complex EVAR centers demonstrating lower mortality rates. Show less
Schaik, J. van; Burghard, M.; Lequin, M.H.; Maren, E.A. van; Dijk, A.M. van; Takken, T.; ... ; Santen, H.M. van 2022
Objective: Children with suprasellar brain damage are at risk of hypothalamic dysfunction (HD). HD may lead to decreased resting energy expenditure (REE). Decreased REE, however, is not present in... Show moreObjective: Children with suprasellar brain damage are at risk of hypothalamic dysfunction (HD). HD may lead to decreased resting energy expenditure (REE). Decreased REE, however, is not present in all children with HD. Our aim was to assess which children suspect for HD have low REE, and its association with clinical severity of HD or radiological hypothalamic damage.Patients and methods: A retrospective cohort study was performed. Measured REE (mREE) of children at risk of HD was compared to predicted REE (pREE). Low REE was defined as mREE <90% of predicted. The mREE/pREE quotient was associated to a clinical score for HD symptoms and to radiological hypothalamic damage.Results: In total, 67 children at risk of HD (96% brain tumor diagnosis) with a mean BMI SDS of +2.3 +/- 1.0 were included. Of these, 45 (67.2%) had low mREE. Children with severe HD had a significant lower mean mREE/pREE quotient compared to children with no, mild, or moderate HD. Mean mREE/pREE quotient of children with posterior hypothalamic damage was significantly lower compared to children with no or anterior damage. Tumor progression or tumor recurrence, severe clinical HD, and panhypopituitarism with diabetes insipidus (DI) were significant risk factors for reduced REE.Conclusion: REE may be lowered in children with hypothalamic damage and is associated to the degree of clinical HD. REE is, however, not lowered in all children suspect for HD. For children with mild or moderate clinical HD symptoms, REE measurements may be useful to distinguish between those who may benefit from obesity treatment that increases REE from those who would be better helped using other obesity interventions. Show less
Schaik, J. van; Burghard, M.; Lequin, M.H.; Maren, E.A. van; Dijk, A.M. van; Takken, T.; ... ; Santen, H.M. van 2022
Objective: Children with suprasellar brain damage are at risk of hypothalamic dysfunction (HD). HD may lead to decreased resting energy expenditure (REE). Decreased REE, however, is not present in... Show moreObjective: Children with suprasellar brain damage are at risk of hypothalamic dysfunction (HD). HD may lead to decreased resting energy expenditure (REE). Decreased REE, however, is not present in all children with HD. Our aim was to assess which children suspect for HD have low REE, and its association with clinical severity of HD or radiological hypothalamic damage.Patients and methods: A retrospective cohort study was performed. Measured REE (mREE) of children at risk of HD was compared to predicted REE (pREE). Low REE was defined as mREE <90% of predicted. The mREE/pREE quotient was associated to a clinical score for HD symptoms and to radiological hypothalamic damage.Results: In total, 67 children at risk of HD (96% brain tumor diagnosis) with a mean BMI SDS of +2.3 +/- 1.0 were included. Of these, 45 (67.2%) had low mREE. Children with severe HD had a significant lower mean mREE/pREE quotient compared to children with no, mild, or moderate HD. Mean mREE/pREE quotient of children with posterior hypothalamic damage was significantly lower compared to children with no or anterior damage. Tumor progression or tumor recurrence, severe clinical HD, and panhypopituitarism with diabetes insipidus (DI) were significant risk factors for reduced REE.Conclusion: REE may be lowered in children with hypothalamic damage and is associated to the degree of clinical HD. REE is, however, not lowered in all children suspect for HD. For children with mild or moderate clinical HD symptoms, REE measurements may be useful to distinguish between those who may benefit from obesity treatment that increases REE from those who would be better helped using other obesity interventions. Show less
Schaik, J. van; Burghard, M.; Lequin, M.; Maren, E. van; Dijk, A. van; Takken, T.; ... ; Santen, H. van 2022
Purpose: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower... Show morePurpose: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) is gaining popularity for the quantification of tissue perfusion, including foot perfusion in patients with lower extremity arterial disease (LEAD). However, the absolute fluorescence intensity is influenced by patient-and system-related factors limiting reliable and valid quantification. To enhance the quality of quantitative perfusion assessment using ICG NIR fluorescence imaging, normalization of the measured time-intensity curves seems useful. Materials and Methods: In this cohort study, the effect of normalization on 2 aspects of ICG NIR fluorescence imaging in assessment of foot perfusion was measured: the repeatability and the region selection. Following intravenous administration of ICG, the NIR fluorescence intensity in both feet was recorded for 10 mins using the Quest Spectrum platform(R). The effect of normalization on repeatability was measured in the nontreated foot in patients undergoing unilateral revascularization preprocedural and postprocedural (repeatability group). The effect of normalization on region selection was performed in patients without LEAD (region selection group). Absolute and normalized time-intensity curves were compared. Results: Successful ICG NIR fluorescence imaging was performed in 54 patients (repeatability group, n = 38; region selection group, n = 16). For the repeatability group, normalization of the time-intensity curves displayed a comparable inflow pattern for repeated measurements. For the region selection group, the maximum fluorescence intensity (Imax) demonstrated significant differences between the 3 measured regions of the foot (P = .002). Following normalization, the time-intensity curves in both feet were comparable for all 3 regions. Conclusion: This study shows the effect of normalization of time-intensity curves on both the repeatability and region selection in ICG NIR fluorescence imaging. The significant difference between absolute parameters in various regions of the foot demonstrates the limitation of absolute intensity in interpreting tissue perfusion. Therefore, normalization and standardization of camera settings are essential steps toward reliable and valid quantification of tissue perfusion using ICG NIR fluorescence imaging. Show less
Hoven, P. van den; Berg, S.D. van den; Valk, J.P. van der; Krogt, H. van der; Doorn, L.P. van; Bogt, K.E.A. van de; ... ; Vorst, J.R. van der 2022
Background: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is... Show moreBackground: Patients with chronic limb threatening ischemia have a risk of undergoing a major amputation within 1 year of nearly 30% with a substantial risk of re-amputation since wound healing is often impaired. Quantitative assessment of regional tissue viability following amputation surgery can identify patients at risk for impaired wound healing. In quantification of regional tissue perfusion, near-infrared (NIR) fluorescence imaging using Indocyanine Green (ICG) seems promising. Methods: This pilot study included adult patients undergoing lower extremity amputation surgery due to peripheral artery disease or diabetes mellitus. ICG NIR fluorescence imaging was performed within 5 days following amputation surgery using the Quest Spectrum Platform (R). Following intravenous administration of ICG, the NIR fluorescence intensity of the amputation wound was recorded for 10 minutes. The NIR fluorescence intensity videos were analyzed and if a fluorescence deficit was observed, this region was marked as "low fluorescence." All other regions were marked as "normal fluorescence." Results: Successful ICG NIR fluorescence imaging was performed in 10 patients undergoing a total of 15 amputations. No "low fluorescence" regions were observed in 11 out of 15 amputation wounds. In 10 out of these 11 amputations, no wound healing problems occurred during followup. Regions with "low fluorescence" were observed in 4 amputation wounds. Impaired wound healing corresponding to these regions was observed in all wounds and a re-amputation was necessary in 3 out of 4. When observing time-related parameters, regions with low fluorescence had a significantly longer time to maximum intensity (113 seconds vs. 32 seconds, P = 0.003) and a significantly lesser decline in outflow after five minutes (80.3% vs. 57.0%, P = 0.003). Conclusions: ICG NIR fluorescence imaging was able to predict postoperative skin necrosis in all four cases. Quantitative assessment of regional perfusion remains challenging due to influencing factors on the NIR fluorescence intensity signal, including camera angle, camera distance and ICG dosage. This was also observed in this study, contributing to a large variety in fluorescence intensity parameters among patients. To provide surgeons with reliable NIR fluorescence cut-off values for prediction of wound healing, prospective studies on the intraoperative use of this technique are required. The potential prediction of wound healing using ICG NIR fluorescence imaging will have a huge impact on patient mortality, morbidity as well as the burden of amputation surgery on health care. Show less
Hers, T.M.; Schaik, J. van; Keekstra, N.; Putter, H.; Hamming, J.F.; Vorst, J.R. van der 2021
Objectives: The aim of this retrospective study was to assess the predictive performance of the American College of Surgeons (ACS) risk calculator for aortic aneurysm repair for the patient... Show moreObjectives: The aim of this retrospective study was to assess the predictive performance of the American College of Surgeons (ACS) risk calculator for aortic aneurysm repair for the patient population of a Dutch tertiary referral hospital. Methods: This retrospective study included all patients who underwent elective endovascular or open aortic aneurysm repair at our institution between the years 2013 and 2019. Preoperative patient demographics and postoperative complication data were collected, and individual risk assessments were generated using five different current procedural terminology (CPT) codes. Receiver operating characteristic (ROC) curves, calibration plots, Brier scores, and Index of Prediction Accuracy (IPA) values were generated to evaluate the predictive performance of the ACS risk calculator in terms of discrimination and calibration. Results: Two hundred thirty-four patients who underwent elective endovascular or open aortic aneurysm repair were identified. Only five out of thirteen risk predictions were found to be sufficiently discriminative. Furthermore, the ACS risk calculator showed a structurally insufficient calibration. Most Brier scores were close to 0; however, comparison to a null model though IPA-scores showed the predictions generated by the ACS risk calculator to be inaccurate. Overall, the ACS risk calculator showed a consistent underestimation of the risk of complications. Conclusions: The ACS risk calculator proved to be inaccurate within the framework of endovascular and open aortic aneurysm repair in our medical center. To minimize the effects of patient selection and cultural differences, multicenter collaboration is necessary to assess the performance of the ACS risk calculator in aortic surgery. Show less
Vonderen, J.J. van; Keus, J.M.H.; Schaik, J. van; Smiers, F.J.; Harkel, D.J. ten; Lopriore, E. 2021
Background In this case report, we describe a very rare case of severe limb ischemia due to an arterial embolus caused by an aneurysm of the oval foramen in a term-born infant that occurred in the... Show moreBackground In this case report, we describe a very rare case of severe limb ischemia due to an arterial embolus caused by an aneurysm of the oval foramen in a term-born infant that occurred in the first few hours after birth. Case presentation A newborn male Caucasian patient presented on the maternity ward with ischemia of the right foot. Ischemia was treated with nitroglycerin spray and low-molecular-weight heparin in therapeutic dosage. An aneurysm of the oval foramen was found during postnatal echocardiography screening. This was thought to be the source of an embolus causing limb ischemia. At birth and upon follow-up, no clotting disorders were found. A large part of the right forefoot was ischemic, leading to loss of digits 1, 2, and 3. No significant loss of function was found in the first year of life. Conclusion Severe limb ischemia can be caused by an embolus arising from an aneurysm of the oval foramen and can be treated with heparin. Show less
Hoven, P. van den; Goncalves, L.N.; Quax, P.H.A.; Rijswijk, C.S.P. van; Schaik, J. van; Schepers, A.; ... ; Vorst, J.R. van der 2021
In assessing the severity of lower extremity arterial disease (LEAD), physicians rely on clinical judgements supported by conventional measurements of macrovascular blood flow. However, current... Show moreIn assessing the severity of lower extremity arterial disease (LEAD), physicians rely on clinical judgements supported by conventional measurements of macrovascular blood flow. However, current diagnostic techniques provide no information about regional tissue perfusion and are of limited value in patients with chronic limb-threatening ischemia (CLTI). Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has been used extensively in perfusion studies and is a possible modality for tissue perfusion measurement in patients with CLTI. In this prospective cohort study, ICG NIR fluorescence imaging was performed in patients with CLTI and control patients using the Quest Spectrum Platform(R) (Middenmeer, The Netherlands). The time-intensity curves were analyzed using the Quest Research Framework. Fourteen parameters were extracted. Successful ICG NIR fluorescence imaging was performed in 19 patients with CLTI and in 16 control patients. The time to maximum intensity (seconds) was lower for CLTI patients (90.5 vs. 143.3, p = 0.002). For the inflow parameters, the maximum slope, the normalized maximum slope and the ingress rate were all significantly higher in the CLTI group. The inflow parameters observed in patients with CLTI were superior to the control group. Possible explanations for the increased inflow include damage to the regulatory mechanisms of the microcirculation, arterial stiffness, and transcapillary leakage. Show less