OBJECTIVESThe objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve... Show moreOBJECTIVESThe objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management.METHODSEchocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated.RESULTSThe cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml.CONCLUSIONSThis pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. Show less
BackgroundImplantation of a bioprosthetic valve is a reasonable choice for patients aged > 65 years. For middle-aged patients there is less certainty about whether a mechanical or bioprosthetic... Show moreBackgroundImplantation of a bioprosthetic valve is a reasonable choice for patients aged > 65 years. For middle-aged patients there is less certainty about whether a mechanical or bioprosthetic valve is best.MethodsThe Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial is evaluating the safety and efficacy of the Avalus bioprosthesis (Medtronic). We evaluated clinical and echocardiographic outcomes through 5 years of follow-up, stratified by age ≤ 65 and >65 years.ResultsTwo hundred seventy-one patients (24.2%) were ≤65 years old and 847 (75.8%) >65 years old. Most patients in both groups were men (217 [80.1%] vs 623 [73.6%], respectively; P = .031). Younger patients had a lower Society of Thoracic Surgeons risk of mortality (1.1% ± 0.9% vs 2.2% ± 1.4%, P < .001), better baseline New York Heart Association class (P = .004), and fewer comorbidities than older patients. At 5 years mortality was lower among younger than older patients (5.3% vs 14.0%, P < .001) and no cases of structural valve deterioration occurred in either group. Effective orifice area was similar between age groups (P = .11), and mean gradient was 13.9 ± 5.4 vs 12.0 ± 4.1 mm Hg (P < .001). Multivariable linear regression identified several parameters associated with mean aortic gradient at 5 years, including baseline age and mean aortic gradient, discharge stroke volume index and EOA, and implanted valve size. Ninety-five percent of patients were in New York Heart Association class I/II through 5 years in both age groups (P = .85).ConclusionsFindings from this analysis demonstrate satisfactory safety, hemodynamic performance, and durability of the Avalus bioprosthesis through a 5-year follow-up in patients aged ≤ 65 and >65 years. Show less
OBJECTIVES This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical... Show moreOBJECTIVES This analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement.METHODS Kaplan-Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated.RESULTS A total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 +/- 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 +/- 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan-Meier survival rate was 88.1% (85.9-90.0%). The Kaplan-Meier event rates were 5.6% (4.3-7.2%) for thromboembolism, 4.4% (3.2-6.0%) for endocarditis, 0.2% (0.0-0.7%) for a major paravalvular leak and 3.2% (2.3-4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 +/- 17.1 mmHg at baseline, to 13.1 +/- 4.7 mmHg at discharge and remained stable at 12.5 +/- 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery.CONCLUSIONS The findings of a high survival rate, excellent safety, no SVD and stable haemodynamic performance and functional status through 5 years of follow-up are encouraging. Additional follow-up is needed to assess the long-term durability of this contemporary surgical bioprosthesis. Show less
OBJECTIVESThis analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical... Show moreOBJECTIVESThis analysis evaluated the safety, durability and haemodynamic performance of a stented bovine pericardial valve through 5 years of follow-up in patients with an indication for surgical aortic valve replacement.METHODSKaplan–Meier analysis was used to estimate the incidence of survival and valve-related thromboembolism, major paravalvular leak, endocarditis, structural valve deterioration (SVD) and reintervention. The mean aortic gradient and New York Heart Association (NYHA) functional class were also evaluated.RESULTSA total of 1118 patients have received the Avalus valve; 564 have completed the 5-year follow-up. The median follow-up was 4.85 years (4810 patient-years total follow-up). At baseline, the mean age was 70.2 ± 9.0 years; 75.1% of patients were male. The Society of Thoracic Surgeons predicted risk of mortality was 2.0 ± 1.4%. Most patients were in NYHA functional class II (46.8%) or III (40.3%). At the 5-year follow-up, the overall Kaplan–Meier survival rate was 88.1% (85.9–90.0%). The Kaplan–Meier event rates were 5.6% (4.3–7.2%) for thromboembolism, 4.4% (3.2–6.0%) for endocarditis, 0.2% (0.0–0.7%) for a major paravalvular leak and 3.2% (2.3–4.6%) for reintervention. There were no cases of SVD. The mean gradient decreased from 42.1 ± 17.1 mmHg at baseline, to 13.1 ± 4.7 mmHg at discharge and remained stable at 12.5 ± 4.6 mmHg at 5 years. More than 95% of patients were in NYHA functional class I/II 5 years after surgery.CONCLUSIONSThe findings of a high survival rate, excellent safety, no SVD and stable haemodynamic performance and functional status through 5 years of follow-up are encouraging. Additional follow-up is needed to assess the long-term durability of this contemporary surgical bioprosthesis. Show less
Background: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate... Show moreBackground: The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR. Methods: Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort ( n = 1077) and in an isolated AVR subcohort ( n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events. Results: Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47-1.55, p = 0.61). Conclusion: Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes. Show less
Background The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate... Show moreBackground The advent of transcatheter aortic valve replacement (AVR) has led to an increased emphasis on reducing the invasiveness of surgical procedures. The aim of this study was to evaluate clinical outcomes and hemodynamic performance achieved with minimally invasive aortic valve replacement (MI-AVR) as compared with conventional AVR.Methods Patients who underwent surgical AVR with the Avalus bioprosthesis, as part of a prospective multicenter non-randomized trial, were included in this analysis. Surgical approach was left to the discretion of the surgeons. Patient characteristics and clinical outcomes were compared between MI-AVR and conventional AVR groups in the entire cohort (n = 1077) and in an isolated AVR subcohort (n = 528). Propensity score adjustment was performed to estimate the effect of MI-AVR on adverse events.Results Patients treated with MI-AVR were younger, had lower STS scores, and underwent concomitant procedures less often. Valve size implanted was comparable between the groups. MI-AVR was associated with longer procedural times in the isolated AVR subcohort. Postprocedural hemodynamic performance was comparable. There were no significant differences between MI-AVR and conventional AVR in early and 3-year all-cause mortality, thromboembolism, reintervention, or a composite of those endpoints within either the entire cohort or the isolated AVR subcohort. After propensity score adjustment, there remained no association between MI-AVR and the composite endpoint (hazard ratio: 0.86, 95% confidence interval: 0.47–1.55, p = 0.61).Conclusion Three-year outcomes after MI-AVR with the Avalus bioprosthetic valve were comparable to conventional AVR. These results provide important insights into the overall ability to reduce the invasiveness of AVR without compromising outcomes. Show less
OBJECTIVES: To improve haemodynamic performance, design modifications of prosthetic valves have been proposed with each new generation of valves. These different designs also impact the amount of... Show moreOBJECTIVES: To improve haemodynamic performance, design modifications of prosthetic valves have been proposed with each new generation of valves. These different designs also impact the amount of mechanical wear, because mechanical stresses are distributed differently. Because long-term evidence for new prosthetic valves is lacking, this in vitro study compared hydrodynamic performance and durability among 3 currently available bioprosthetic valves with internally (IMLV) or externally mounted leaflets (EMLV).METHODS: Prostheses of the internally mounted Medtronic Avalus and Carpentier-Edwards Perimount Magna Ease valves were compared to prostheses of the externally mounted Abbott Trifecta valve. For each labelled size (e.g. 19, 21 and 23) of the 3 types, 3 valves underwent accelerated wear testing for up to 600 million cycles, corresponding to similar to 15 years of simulated wear. The valves underwent hydrodynamic testing and visual inspection.RESULTS: EMLV had the largest effective orifice area and lowest pressure gradient for each labelled size at baseline and 600 million cycles; the effective orifice area and the pressure gradient were equivalent for the 2 types of IMLV. Five of 9 EMLVs had at least 1 hole or tear in the leaflet tissue around the stent posts, which resulted in severe regurgitation at 500 million cycles in 2 cases. All IMLVs were intact at 600 million cycles with minimal tissue wear.CONCLUSIONS: EMLV showed superior hydrodynamic performance but inferior mechanical durability compared to IMLV after 600 million cycles of testing. The primary failures were because of significant mechanical abrasion in the commissural region, which may warrant close monitoring of EMLV during long-term follow-up. Show less