A comparison of methods to decrease RF power dissipation and related heating in conductive samples using passive conductors surrounding a sample in a solenoid coil is presented. Full-Maxwell finite... Show moreA comparison of methods to decrease RF power dissipation and related heating in conductive samples using passive conductors surrounding a sample in a solenoid coil is presented. Full-Maxwell finite difference time domain numerical calculations were performed to evaluate the effect of the passive conductors by calculating conservative and rnagnetically-induced electric field and magnetic field distributions. To validate the simulation method, experimental measurements of temperature increase were conducted using a solenoidal coil (diameter 3 mm), a saline sample (10 mM NaCl) and passive copper shielding wires (50 mu m diameter). The temperature increase was 58% lower with the copper wires present for several different input powers to the coil. This was in good agreement with simulation for the same geometry, which indicated 57% lower power dissipated in the sample with conductors present. Simulations indicate that some designs should be capable of reducing temperature increase by more than 85%. (C) 2009 Elsevier Inc. All rights reserved. Show less
It is important to accurately characterize the heating of tissues due to the radiofrequency energy applied during MRI. This has led to an increase in the use of numerical methods to predict... Show moreIt is important to accurately characterize the heating of tissues due to the radiofrequency energy applied during MRI. This has led to an increase in the use of numerical methods to predict specific energy absorption rate distributions for safety assurance in MRI. To ensure these methods are accurate for actual MRI coils, however, it is necessary to compare to experimental results. Here, we report results of some recent efforts to experimentally map temperature change and specific energy absorption rate in a phantom and in vivo where the only source of heat is the radiofrequency fields produced by the imaging coil. Results in a phantom match numerical simulation well, and preliminary results in vivo show measurable temperature increase. With further development, similar methods may be useful for verifying numerical methods for predicting specific energy absorption rate distributions and in some cases for directly measuring temperature changes and specific energy absorption rate induced by the radiofrequency fields in MRI experiments. Magn Reson Med 63:218-223, 2010. (C) 2009 Wiley-Liss, Inc. Show less