Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR)... Show morePresented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r = 0.77 (N = 218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0 x 10(16) molecules cm(-2), i.e. ranging from moderate to polluted conditions, the relative difference is on average similar to 0-5% with a standard deviation of 25-50 %, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0x x 10(16) molecules cm(-2)) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of similar to 20 to 40 %. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at similar to 850 hPa (similar to 1.5 km). At this level the median absolute difference is 0.87 (std = +/- 0.08) ppb, corresponding to a median relative difference of 39%(std = +/- 2 %). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions. Show less
Dammers, E.; Palm, M.; Van Damme, M.; Vigouroux, C.; Smale, D.; Conway, S.; ... ; Erisman, J.W. 2016
Global distributions of atmospheric ammonia (NH3) measured with satellite instruments such as the Infrared Atmospheric Sounding Interferometer (IASI) contain valuable information on NH3... Show moreGlobal distributions of atmospheric ammonia (NH3) measured with satellite instruments such as the Infrared Atmospheric Sounding Interferometer (IASI) contain valuable information on NH3 concentrations and variability in regions not yet covered by ground-based instruments. Due to their large spatial coverage and (bi-)daily overpasses, the satellite observations have the potential to increase our knowledge of the distribution of NH3 emissions and associated seasonal cycles. However the observations remain poorly validated, with only a handful of available studies often using only surface measurements without any vertical information. In this study, we present the first validation of the IASI-NH3 product using ground-based Fourier transform infrared spectroscopy (FTIR) observations. Using a recently developed consistent retrieval strategy, NH3 concentration profiles have been retrieved using observations from nine Network for the Detection of Atmospheric Composition Change (NDACC) stations around the world between 2008 and 2015. We demonstrate the importance of strict spatiotemporal collocation criteria for the comparison. Large differences in the regression results are observed for changing intervals of spatial criteria, mostly due to terrain characteristics and the short lifetime of NH3 in the atmosphere. The seasonal variations of both datasets are consistent for most sites. Correlations are found to be high at sites in areas with considerable NH3 levels, whereas correlations are lower at sites with low atmospheric NH3 levels close to the detection limit of the IASI instrument. A combination of the observations from all sites (N-obs = 547) give a mean relative difference of -32.4 +/- (56.3) %, a correlation r of 0.8 with a slope of 0.73. These results give an improved estimate of the IASI-NH3 product performance compared to the previous upper-bound estimates (-50 to + 100 %). Show less
We present a retrieval method for ammonia (NH3) total columns from ground-based Fourier transform infrared (FTIR) observations. Observations from Bremen (53.10 degrees N, 8.85 degrees E), Lauder ... Show moreWe present a retrieval method for ammonia (NH3) total columns from ground-based Fourier transform infrared (FTIR) observations. Observations from Bremen (53.10 degrees N, 8.85 degrees E), Lauder (45.04 degrees S, 169.68 degrees E), Reunion (20.9 degrees S, 55.50 degrees E) and Jungfraujoch (46.55 degrees N, 7.98 degrees E) were used to illustrate the capabilities of the method. NH3 mean total columns ranging 3 orders of magnitude were obtained, with higher values at Bremen (mean of 13 : 47 x 10(15) molecules cm(-2)) and lower values at Jungfraujoch (mean of 0 : 18 x 10(15) molecules cm(-2)). In conditions with high surface concentrations of ammonia, as in Bremen, it is possible to retrieve information on the vertical gradient, as two layers can be distinguished. The retrieval there is most sensitive to ammonia in the planetary boundary layer, where the trace gas concentration is highest. For conditions with low concentrations, only the total column can be retrieved. Combining the systematic and random errors we have a mean total error of 26% for all spectra measured at Bremen (number of spectra (N) = 554), 30% for all spectra from Lauder (N = 2412), 25% for spectra from Reunion (N = 1262) and 34% for spectra measured at Jungfraujoch (N = 2702). The error is dominated by the systematic uncertainties in the spectroscopy parameters. Station-specific seasonal cycles were found to be consistent with known seasonal cycles of the dominant ammonia sources in the station surroundings. The developed retrieval methodology from FTIR instruments provides a new way of obtaining highly time-resolved measurements of ammonia burdens. FTIR-NH3 observations will be useful for understanding the dynamics of ammonia concentrations in the atmosphere and for satellite and model validation. It will also provide additional information to constrain the global ammonia budget. Show less