Background Fetal and neonatal alloimmune thrombocytopenia (FNAIT) is a rare disease that untreated can lead to intracranial haemorrhage or death. The natural history of FNAIT is still unclear;... Show moreBackground Fetal and neonatal alloimmune thrombocytopenia (FNAIT) is a rare disease that untreated can lead to intracranial haemorrhage or death. The natural history of FNAIT is still unclear; therefore, the benefits of screening cannot be estimated and no routine screening is yet in place. We aimed to assess the incidence of clinically detectable FNAIT among pregnancies in human platelet antigen-1a (HPA-1a)-immunised women. Methods We did a prospective observational cohort study of pregnant women negative for rhesus D (RhD) and rhesus c (Rhc) antigens, without age limits, who underwent routine antenatal screening for red cell antibodies at 27 weeks' gestation and were typed for HPA-1a between March 1, 2017, and May 1, 2020. HPA-1a-negative women were tested for HPA alloantibodies. Health-care professionals were masked to all test results. The main outcome was the proportion of neonates with severe, clinically detectable FNAIT, defined as having an intracranial bleed, organ bleed, or bleeding-related death observed during pregnancy or within the first week of life. Cases of clinically detectable FNAIT not categorised as severe were categorised as mild. This study is registered with ClinicalTrials.gov (NCT04067375). Findings Of 153 106 women typed for HPA-1a, 3722 (2 center dot 4%) were negative for HPA-1a. 913 HPA-1a-negative women gave informed consent, underwent HPA-1a antibody screening, and were included in the study. Anti-HPA-1a antibodies were detected in 85 HPA-1a-negative participants, among whom three with HPA-1a-negative fetuses and one with a previous child with FNAIT were excluded. As controls, 820 HPA-1a-negative, non-immunised pregnancies and 2704 randomly selected pregnancies of women negative for RhD and Rhc who were typed HPA-1a positive were included. Of 81 fetuses included, one (1 center dot 2%) was diagnosed with severe HPA-1a-mediated intracranial haemorrhage and three (3 center dot 7%) had mild FNAIT. Gravidity and parity did not seem to be risk factors for HPA-1a immunisation. 73 (90 center dot 1%) of 81 HPA-1a-immunised women were positive for HLA-DRB3*01:01. Interpretation Our data suggest that, without intervention, the incidence of major clinically detectable bleeding in FNAIT is estimated as 11 (95% CI 0-32) per 10 000 HPA-1a-negative pregnancies. These findings imply that severe bleeding is a rare event that potentially could be prevented by a screening programme. Show less
Porcelijn, L.; Schmidt, D.E.; Oldert, G.; Hofstede-van Egmond, S.; Kapur, R.; Zwaginga, J.J.; Haas, M. de 2020
To this day, immune thrombocytopenia (HT) remains a clinical diagnosis made by exclusion of other causes for thrombocytopenia. Reliable detection of platelet autoantibodies would support the... Show moreTo this day, immune thrombocytopenia (HT) remains a clinical diagnosis made by exclusion of other causes for thrombocytopenia. Reliable detection of platelet autoantibodies would support the clinical diagnosis, but the lack of specificity and sensitivity of the available methods for platelet autoantibody testing limits their value in the diagnostic workup of thrombocytopenia. The introduction of methods for glycoprotein-specific autoantibody detection has improved the specificity of testing and is acceptable for ruling in ITP but not ruling it out as a diagnosis. The sensitivity of these assays varies widely, even between studies using comparable assays. A review of the relevant literature combined with our own laboratory's experience of testing large number of serum and platelet samples makes it clear that this variation can be explained by variations in the characteristics of the tests, including in the glycoprotein-specific monoclonal antibodies, the glycoproteins that are tested, the platelet numbers used in the assay and the cutoff levels for positive and negative results, as well as differences in the tested patient populations. In our opinion, further standardization and optimization of the direct autoantibody detection methods to increase sensitivity without compromising specificity seem possible but will still likely be insufficient to distinguish the often very weak specific autoantibody signals from background signals. Further developments of autoantibody detection methods will therefore be necessary to increase sensitivity to a level acceptable to provide laboratory confirmation of a diagnosis of ITP. (C) 2020 The Author(s). Published by Elsevier Inc. Show less
Winkelhorst, D.; Porcelijn, L.; Muizelaar, E.; Oldert, G.; Huiskes, E.; Schoot, C.E. van der 2019
BACKGROUND:Fetal and neonatal alloimmune thrombocytopenia (FNAIT) is caused by maternal alloantibodies against fetal human platelet antigens (HPAs), mostly caused by anti-HPA-1a. Population-based... Show moreBACKGROUND:Fetal and neonatal alloimmune thrombocytopenia (FNAIT) is caused by maternal alloantibodies against fetal human platelet antigens (HPAs), mostly caused by anti-HPA-1a. Population-based screening for FNAIT is still a topic of debate. Logistically and financially, the major challenge for implementation is the typing of pregnant women to recognize the 2% HPA-1a-negative women. Therefore, there is need for a high-throughput and low-cost HPA-1a-typing assay.STUDY DESIGN AND METHODS:A sandwich ELISA was developed, using a monoclonal anti-GPIIIa as coating antibody and horseradish-peroxidase-conjugated recombinant anti-HPA-1a, as detecting antibody. The ELISA results were compared to an allelic discrimination PCR-assay. In phase I, samples from unselected consecutive pregnant women were tested with both assays. Phase II was part of a prospective screening study in pregnancy and genotyping was restricted to samples with an arbitrary set, OD < 0.500.RESULTS:The ELISA was optimized to require no additional handling (swirling or spinning) of stored tubes. During phase I, 506 samples were tested. In phase II, another 62,171 consecutive samples were phenotyped, with supportive genotyping in 1,902. In total 1,585 HPA-1a negative and 823 HPA-1a positive women were genotyped. The assay reached 100% sensitivity with a cut-off OD from 0.160, corresponding with a 99.9% specificity and a false-HPA-1a negative rate of 0.03.CONCLUSION:A high-throughput, low-cost, and reliable HPA-1a phenotyping assay was developed which can be used in population-based screening to select samples for testing of presence of anti-HPA-1a. Because plasma from tubes of 3- to 6-days-old samples can be used, this assay is applicable to settings with suboptimal conditions. Show less
Porcelijn, L.; Huiskes, E.; Oldert, G.; Schipperus, M.; Zwaginga, J.J.; Haas, M. de 2018