Background: A common complication after a DIEP flap reconstruction is the occurrence of fat necrosis due to inadequate flap perfusion zones. Intraoperative identification of ischemic zones in the... Show moreBackground: A common complication after a DIEP flap reconstruction is the occurrence of fat necrosis due to inadequate flap perfusion zones. Intraoperative identification of ischemic zones in the DIEP flap could be opti-mized using indocyanine green near-infrared fluorescence angiography (ICG-NIR-FA). This randomized controlled trial aims to determine whether intraoperative ICG-NIR-FA for the assessment of DIEP flap perfusion decreases the occurrence of fat necrosis. Design/methods: This article describes the protocol of a Dutch multicenter randomized controlled clinical trial: the FAFI-trial. Females who are electively scheduled for autologous breast reconstruction using DIEP or muscle -sparing transverse rectus abdominis muscle (msTRAM) flaps are included. A total of 280 patients will be included in a 1:1 ratio between both study arms. In the intervention arm, the intraoperative assessment of flap perfusion will be based on both regular clinical parameters and ICG-NIR-FA. The control arm consists of flap perfusion evaluation only through the regular clinical parameters, while ICG-NIR-FA images are obtained during surgery for which the surgeon is blinded. The main study endpoint is the difference in percentage of clinically relevant fat necrosis between both study arms, evaluated two weeks and three months after reconstruction. Conclusion: The FAFI-trial, a Dutch multicenter randomized controlled clinical trial, aims to investigate the clinical added value of intraoperative use of standardized ICG-NIR-FA for assessment of DIEP/msTRAM flap perfusion in the reduction of fat necrosis. Clinical trial registration number: NCT05507710; NL 68623.058.18. Show less
BackgroundThe diagnostic process of patients with suspect pancreatic lesions is often lengthy and prone to repeated diagnostic procedures due to inconclusive results. Targeted Next-Generation... Show moreBackgroundThe diagnostic process of patients with suspect pancreatic lesions is often lengthy and prone to repeated diagnostic procedures due to inconclusive results. Targeted Next-Generation Sequencing (NGS) performed on cytological material obtained with fine needle aspiration (FNA) or biliary duct brushing can speed up this process. Here, we study the incremental value of NGS for establishing the correct diagnosis, and subsequent treatment plan in patients with inconclusive diagnosis after regular diagnostic work-up for suspect pancreatic lesions.Methods In this prospective cross-sectional cohort study, patients were screened for inclusion in four hospitals. NGS was performed with AmpliSeq Cancer Hotspot Panel v2 and v4b in patients with inconclusive cytology results or with an uncertain diagnosis. Diagnostic results were evaluated by the oncology pancreatic multidisciplinary team. The added value of NGS was determined by comparing diagnosis (malignancy, cystic lesion or benign condition) and proposed treatment plan (exploration/resection, neoadjuvant chemotherapy, follow-up, palliation or repeated FNA) before and after integration of NGS results. Final histopathological analysis or a 6-month follow-up period were used as the reference standard in case of surgical intervention or non-invasive treatment, respectively.Results In 50 of the 53 included patients, cytology material was sufficient for NGS analysis. Diagnosis before and after integration of NGS results differed in 24% of the patients. The treatment plan was changed in 32% and the diagnosis was substantiated by the NGS data in 44%. Repetition of FNA/brushing was prevented in 14% of patients. All changes in treatment plan were correctly made after integration of NGS. Integration of NGS increased overall diagnostic accuracy from 68% to 94%.Interpretation This study demonstrates the incremental diagnostic value of NGS in patients with an initial inconclusive diagnosis. Integration of NGS results can prevent repeated EUS/FNA, and can also rigorously change the final diagnosis and treatment plan. Show less
Tumor visualization with near-infrared fluorescence (NIRF) imaging might aid exploration and resection of pancreatic cancer by visualizing the tumor in real time. Conjugation of the near-infrared... Show moreTumor visualization with near-infrared fluorescence (NIRF) imaging might aid exploration and resection of pancreatic cancer by visualizing the tumor in real time. Conjugation of the near-infrared fluorophore IRDye800CW to the monoclonal antibody bevacizumab enables targeting of vascular endothelial growth factor A. The aim of this study was to determine whether intraoperative tumor-specific imaging of pancreatic cancer with the fluorescent tracer bevacizumab-800CW is feasible and safe. Methods: In this multicenter dose-escalation phase I trial, patients in whom pancreatic ductal adenocarcinoma (PDAC) was suspected were administered bevacizumab-800CW (4.5, 10, or 25 mg) 3 d before surgery. Safety monitoring encompassed allergic or anaphylactic reactions and serious adverse events attributed to bevacizumab-800CW. Intraoperative NIRF imaging was performed immediately after laparotomy, just before and after resection of the specimen. Postoperatively, fluorescence signals on the axial slices and formalin-fixed paraffin-embedded tissue blocks from the resected specimens were correlated with histology. Subsequently, tumor-to-background ratios (TBR) were calculated. Results: Ten patients with clinically suspected PDAC were enrolled in the study. Four of the resected specimens were confirmed PDACs; other malignancies were distal cholangiocarcinoma, ampullary carcinoma, and neuroendocrine tumors. No serious adverse events were related to bevacizumab-800CW. In vivo tumor visualization with NIRF imaging differed per tumor type and was nonconclusive. Ex vivo TBRs were 1.3, 1.5, and 2.5 for the 4.5-, 10-, and 25-mg groups, respectively. Conclusion: NIRF-guided surgery in patients with suspected PDAC using bevacizumab-IRDye800CW is feasible and safe. However, suboptimal TBRs were obtained because no clear distinction between pancreatic cancer from normal or inflamed pancreatic tissue was achieved. Therefore, a more tumor-specific tracer than bevacizumab-IRDye800CWfor PDAC is preferred. Show less
Hoven, P. van den; Verduijn, P.S.; Capelle, L. van; Tange, F.P.; Michi, M.; Corion, L.U.M.; ... ; Vorst, J.R. van der 2022
Background: One of the complications of free flap breast reconstruction is the oc-currence of skin and fat necrosis. Intra-operative use of near-infrared (NIR) fluorescence imag-ing with... Show moreBackground: One of the complications of free flap breast reconstruction is the oc-currence of skin and fat necrosis. Intra-operative use of near-infrared (NIR) fluorescence imag-ing with Indocyanine Green (ICG) has the potential to predict these complications. In this study, the quantification of the fluorescence intensity measured in free flap breast reconstruction was performed to gain insight into the perfusion patterns observed with ICG NIR fluorescence imag-ing.Methods: ICG NIR fluorescence imaging was performed in patients undergoing free flap breast reconstruction following mastectomy. After completion of the arterial and venous anastomosis, 7.5 mg ICG was administered intravenously. The fluorescence intensity over time was recorded using the Quest Spectrum Platform (R). Four regions of interest (ROI) were selected based on location and interpretation of the NIR fluorescence signal: (1) The perforator, (2) normal per -fusion, (3) questionable perfusion, and (4) low perfusion. Time-intensity curves were analyzed, and two parameters were extracted: Tmax and Tmax slopes.Results: Successful ICG NIR fluorescence imaging was performed in 13 patients undergoing 17 free flap procedures. Region selection included 16 perforators, 17 normal perfusions, 8 ques-tionable perfusions, and 5 low perfusion ROIs. Time-intensity curves of the perforator ROIs were comparable to the ROIs of normal perfusion and demonstrated a fast inflow. No outflow was observed for the ROIs with questionable and low perfusion.Conclusion: This study provides insight into the perfusion patterns observed with ICG NIR flu-orescence imaging in free flap breast reconstruction. Future studies should correlate quantita-tive parameters with clinical perfusion assessment and outcome.(c) 2022 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Pub-lished by Elsevier Ltd. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ) Show less
Michi, Verduijn, as it either provided additional information about perfusion or confirmed the clinical assess-ment. Our pilot study showed a significant decrease of FN in patients undergoing an... Show moreMichi, Verduijn, as it either provided additional information about perfusion or confirmed the clinical assess-ment. Our pilot study showed a significant decrease of FN in patients undergoing an ABR with a DIEP when near-infrared fluorescence imaging was used to assess flap perfusion. This study provides a standardized working protocol for near-infrared fluorescence imaging. In the future, large multicenter studies should focus on the quantification of near-infrared fluorescence imaging. (c) 2021 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Else-vier Ltd. This is an open access article under the CC BY license ( http://creativecommons.org/licenses/by/4.0/ ) Show less
Background: Almost a third of the resections in patients with colorectal liver metastases (CRLM) undergoing curative surgery, end up being tumor-margin positive (<= 1 mm margin). Near-infrared... Show moreBackground: Almost a third of the resections in patients with colorectal liver metastases (CRLM) undergoing curative surgery, end up being tumor-margin positive (<= 1 mm margin). Near-infrared fluorescent (NIRF) imaging using the fluorescent contrast agent indocyanine green (ICG) has been studied for many different applications. When administered in a relatively low dose (10 mg) 24 hours prior to surgery, ICG accumulated in hepatocytes surrounding the CRLM. This results in the formation of a characteristic fluorescent 'rim' surrounding CRLM when located at the periphery of the liver. By resecting the metastasis with the entire surrounding fluorescent rim, in real-time guided by NIRF imaging, the surgeon can effectively acquire margin-negative (>1 mm) resections. This pilot study aims to describe the surgical technique for using near-infrared fluorescence imaging to assess tumor-margins in vivo in patients with CRLM undergoing laparoscopic or robot-assisted resections.Methods: Out of our institutional database we selected 16 CRLM based on margin-status (R0; n=8, R1; n=8), which were resected by a minimally-invasive approach using ICG-fluorescence. NIRF images acquired during surgery, from both the resection specimen and the wound bed, were analysed for fluorescent signal. We hypothesized that a protruding fluorescent rim at the parenchymal side of the resection specimen could indicate a too close proximity to the tumor and could be predictive for a tumor-positive surgical margin. NIRF images were correlated to final histopathological assessment of the resection margin.Results: All lesions with a NIRF positive resection plane in vivo were reported as having a tumor-positive margin. Lesions that showcased no protruding rim in the wound bed in vivo were diagnosed as having a tumor-negative margin in 88% of cases. A 5-step surgical workflow is described to document the NIRF signal was used assess the resection margin in vivo for future clinical studies.Conclusions: The pilot study shows that image-guided surgery using real-time ICG-fluorescence has the potential to aid surgeons in achieving a tumor-negative margin in minimally invasive liver metastasectomies. The national multi-centre MIMIC-Trial will prospectively study the effect of this technique on surgical tumor-margins (Dutch Trial Register number NL7674). Show less
Surgical exploration in patients with pancreatic or periampullary cancer is often performed without intraoperative image guidance. Although intraoperative ultrasound (IOUS) may enhance... Show moreSurgical exploration in patients with pancreatic or periampullary cancer is often performed without intraoperative image guidance. Although intraoperative ultrasound (IOUS) may enhance visualization during resection, this tool has not been investigated in detail until now. Here, we performed a prospective cohort study to evaluate the effect of IOUS on surgical strategy and to evaluate whether vascular involvement and radicality of the resection could be correctly assessed with IOUS. IOUS was performed by an experienced abdominal radiologist during surgical exploration in 31 consecutive procedures. IOUS affected surgical strategy by either (i) having no effect, (ii) determining tumor localization, (iii) evaluating vascular involvement or (iv) waiving surgery. Radicality of the resections and vascular contact were determined during pathologic analysis and compared with preoperative imaging and IOUS findings. Overall, IOUS influenced surgical strategy in 61% of procedures. In 21 out of 27 malignant tumors, a radical resection was achieved (78%). Vascular contact was assessed correctly using IOUS in 89% compared with 74% of patients using preoperative imaging. IOUS can help the surgical team to assess the resectability and to visualize the tumor and possible vascular contact in real time during resection. IOUS may therefore increase the likelihood of achieving a radical resection. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved. Show less
CDKN2A-p16-Leiden mutation carriers have a substantial risk of developing pancreatic ductal adenocarcinoma (PDAC). One of the main clinical features of hereditary cancer is the development of... Show moreCDKN2A-p16-Leiden mutation carriers have a substantial risk of developing pancreatic ductal adenocarcinoma (PDAC). One of the main clinical features of hereditary cancer is the development of multiple cancers. Since 2000, we have run a surveillance program for CDKN2A-p16-Leiden mutation carriers. The patients are offered a yearly MRI with optionally endoscopic ultrasound. In patients with a confirmed lesion, usually, a partial resection of the pancreas is recommended. A total of 18 PDAC (8.3%) were detected in 218 mutation carriers. In this report, we describe two CDKN2A-p16-Leiden patients with a synchronous and metachronous PDAC. Including two previously-reported cases, we identified four patients with multiple PDAC: two of 18 patients within the surveillance program (11%) and two patients with a proven CDKN2A-p16-Leiden mutation not participating in the surveillance program. In conclusion, this study demonstrated a high risk of developing multiple PDAC in CDKN2A-p16-Leiden mutation carriers. After detecting a primary tumor, it is very important to exclude the presence of a second synchronous tumor. Moreover, after a partial pancreatectomy for PDAC, close surveillance is necessary. In view of the current findings, offering a total pancreatectomy might be an appropriate option in patients with an early PDAC. Show less