Background: Uncontrolled hypertension notwithstanding the use of at least three drugs or hypertension controlled with at least four drugs, the widely accepted definition of treatment-resistant... Show moreBackground: Uncontrolled hypertension notwithstanding the use of at least three drugs or hypertension controlled with at least four drugs, the widely accepted definition of treatment-resistant hypertension (TRH), is considered as a common problem in the hemodialysis population. However, to date there is no estimate of the prevalence of this condition in hemodialysis patients. Method: We estimated the prevalence of TRH by 44-h ambulatory BP monitoring (ABPM) in 506 hemodialysis patients in 10 renal units in Europe included in the registry of the European Renal and Cardiovascular Medicine (EURECAm,), a working group of the European Association, European Dialysis and Transplantation Association (ERA EDTA). In a sub-group of 114 patients, we tested the relationship between fluid overload (Body Composition monitor) and TRH. Results: The prevalence of hypertension with 44-h ABPM criteria was estimated at 85.6% (434 out of 506 patients). Of these, 296 (58%) patients were classified as uncontrolled hypertensive patients by 44-h ABPM criteria (>= 130/80 mmHg). Two hundred and thirteen patients had uncontrolled hypertension while on treatment with less than three drugs and 210 patients were normotensive while on drug therapy (n = 138) or off drug treatment (n = 72). The prevalence of TRH was 24% (93 among 386 treated hypertensive patients). The prevalence of predialysis fluid overload was 33% among TRH patients, 34% in uncontrolled hypertensive patients and 26% in normotensive patients. The vast majority (67%) of hemodialysis patients with TRH had no fluid overload. Conclusion: TRH occurs in about one in four treated hypertensive patients on hemodialysis. Fluid overload per se only in part explains TRH and the 67% of these patients show no fluid overload. Show less
Background. Population-specific consensus documents recommend that the diagnosis of hypertension in haemodialysis patients be based on 48-h ambulatory blood pressure ( ABP) monitoring. However,... Show moreBackground. Population-specific consensus documents recommend that the diagnosis of hypertension in haemodialysis patients be based on 48-h ambulatory blood pressure ( ABP) monitoring. However, until now there is just one study in the USA on the prevalence of hypertension in haemodialysis patients by 44-h recordings. Since there is a knowledge gap on the problem in European countries, we reassessed the problem in the European Cardiovascular and Renal Medicine working group Registry of the European Renal Association-European Dialysis and Transplant Association.Methods. A total of 396 haemodialysis patients underwent 48-h ABP monitoring during a regular haemodialysis session and the subsequent interdialytic interval. Hypertension was defined as (i) pre-haemodialysis blood pressure (BP) >= 140/90 mmHg or use of antihypertensive agents and (ii) ABP >= 130/80 mmHg or use of antihypertensive agents.Results. The prevalence of hypertension by 48-h ABP monitoring was very high (84.3%) and close to that by prehaemodialysis BP (89.4%) but the agreement of the two techniques was not of the same magnitude (j statistics = 0.648; P<0.001). In all, 290 participants were receiving antihypertensive treatment. In all, 9.1% of haemodialysis patients were categorized as normotensives, 12.6% had controlled hypertension confirmed by the two BP techniques, while 46.0% had uncontrolled hypertension with both techniques. The prevalence of white coat hypertension was 18.2% and that of masked hypertension 14.1%. Of note, hypertension was confined only to night-time in 22.2% of patients while just 1% of patients had only daytime hypertension. Predialysis BP >= 140/90 mmHg had 76% sensitivity and 54% specificity for the diagnosis of BP >= 130/80 mmHg by 48-h ABP monitoring.Conclusions. The prevalence of hypertension in haemodialysis patients assessed by 48-h ABP monitoring is very high. Prehaemodialysis BP poorly reflects the 48 h-ABP burden. About a third of the haemodialysis population has white coat or masked hypertension. These findings add weight to consensus documents supporting the use of ABP monitoring for proper hypertension diagnosis and treatment in this population. Show less