Current approaches to study glycosylation of polyclonal human immunoglobulins G (IgG) usually imply protein digestion or glycan release. While these approaches allow in-depth characterization, they... Show moreCurrent approaches to study glycosylation of polyclonal human immunoglobulins G (IgG) usually imply protein digestion or glycan release. While these approaches allow in-depth characterization, they also result in a loss of valuable information regarding certain subclasses, allotypes and co-occuring post-translational modifications (PTMs). Unfortunately, the high variability of polyclonal IgGs makes their intact mass spectrometry (MS) analysis extremely challenging. We propose here a middle-up strategy for the analysis of the intact fragment crystallizable (Fc) region of human plasma IgGs, with the aim of acquiring integrated information of theN-glycosylation and other PTMs of subclasses and allotypes. Human plasma IgG was isolated using Fc-specific beads followed by an on-bead C(H)2 domain digestion with the enzyme IdeS. The obtained mixture of Fc subunits was analyzed by capillary electrophoresis (CE) and hydrophilic interaction liquid chromatography (HILIC) hyphenated with MS. CE-MS provided separation of different IgG-subclasses and allotypes, while HILIC-MS allowed resolution of the different glycoforms and their oxidized variants. The orthogonality of these techniques was key to reliably assign Fc allotypes. Five individual donors were analyzed using this approach. Heterozygosis was observed in all the analyzed donors resulting in a total of 12 allotypes identified. The assignments were further confirmed using recombinant monoclonal IgG allotypes as standards. While the glycosylation patterns were similar within allotypes of the same subclass, clear differences were observed between IgG subclasses and donors, highlighting the relevance of the proposed approach. In a single analysis, glycosylation levels specific for each allotype, relative abundances of subclasses and information on co-occurring modifications are obtained. This middle-up method represents an important step toward a comprehensive analysis of immunoglobulin G-Fc variants. Show less
Gargano, A.F.G.; Schouten, O.; Schaick, G. van; Roca, L.S.; Berg-Verleg, J.H. van den; Haselberg, R.; ... ; Somsen, G.W. 2020
Many industrial enzymes exhibit macro- and micro-heterogeneity due to co-occurring post-translational modifications. The resulting proteoforms may have different activity and stability and,... Show moreMany industrial enzymes exhibit macro- and micro-heterogeneity due to co-occurring post-translational modifications. The resulting proteoforms may have different activity and stability and, therefore, the characterization of their distributions is of interest in the development and monitoring of enzyme products. Protein glycosylation may play a critical role as it can influence the expression, physical and biochemical properties of an enzyme.We report the use of hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) to profile intact glycoform distributions of high mannose-type N-glycosylated proteins, using an industrially produced fungal lipase for the food industry as an example. We compared these results with conventional reversed phase LC-MS (RPLC-MS) and sodium dodecyl sulfate-polyacrylamide gel-electrophoresis (SDS-PAGE). HILIC appeared superior in resolving lipase heterogeneity, facilitating mass assignment of N-glycoforms and sequence variants. In order to understand the glycoform selectivity provided by HILIC, fractions from the four main HILIC elution bands for lipase were taken and subjected to SDS-PAGE and bottom-up proteomic analysis. These analyses enabled the identification of the most abundant glycosylation sites present in each fraction and corroborated the capacity of HILIC to separate protein glycoforms based on the number of glycosylation sites occupied.Compared to RPLC-MS, HILIC-MS reducted the sample complexity delivered to the mass spectrometer, facilitating the assignment of the masses of glycoforms and sequence variants as well as increasing the number of glycoforms detected (69 more proteoforms, 177% increase). The HILIC-MS method required relatively short analysis time (<30 min), in which over 100 glycoforms were distinguished.We suggest that HILIC(-MS) can be a valuable tool in characterizing bioengineering processes aimed at steering protein glycoform expression as well as to check the consistency of product batches. (C) 2020 Elsevier B.V. All rights reserved. Show less
Protein glycosylation is one of the most common and critical post-translational modification, which results from covalent attachment of carbohydrates to protein backbones. Glycosylation affects the... Show moreProtein glycosylation is one of the most common and critical post-translational modification, which results from covalent attachment of carbohydrates to protein backbones. Glycosylation affects the physicochemical properties of proteins and potentially their function. Therefore it is important to establish analytical methods which can resolve glycoforms of glycoproteins. Recently, hydrophilic-interaction liquid chromatography (HILIC)-mass spectrometry has demonstrated to be a useful tool for the efficient separation and characterization of intact protein glycoforms. In particular, amide-based stationary phases in combination with acetonitrile-water gradients containing ion-pairing agents, have been used for the characterization of glycoproteins. However, finding the optimum gradient conditions for glycoform resolution can be quite tedious as shallow gradients (small decrease of acetonitrile percentage in the elution solvent over a long time) are required. In the present study, the retention mechanism and peak capacity of HILIC for non-glycosylated and glycosylated proteins were investigated and compared to reversed-phase liquid chromatography (RPLC). For both LC modes, In k vs. phi plots of a series of test proteins were calculated using linear solvent strength (LSS) analysis. For RPLC, the plots were spread over a wider phi range than for HILIC, suggesting that HILIC methods require shallower gradients to resolve intact proteins. Next, the usefulness of computer-aided method development for the optimization of the separation of intact glycoform by HILIC was examined. Five retention models including LSS, adsorption, and mixed-mode, were tested to describe and predict glycoprotein retention under gradient conditions. The adsorption model appeared most suited and was applied to the gradient prediction for the separation of the glycoforms of six glycoproteins (Ides-digested trastuzumab, alpha-acid glycoprotein, ovalbumin, fetuin and thyroglobulin) employing the program PIOTR. Based on the results of three scouting gradients, conditions for high-efficiency separations of protein glycoforms varying in the degree and complexity of glycosylation was achieved, thereby significantly reducing the time needed for method optimization. (C) 2019 Elsevier B.V. All rights reserved. Show less
Recent progress in top-down proteomics has driven the demand for chromatographic methods compatible with mass spectrometry (MS) that can separate intact proteins. Hydrophilic interaction liquid... Show moreRecent progress in top-down proteomics has driven the demand for chromatographic methods compatible with mass spectrometry (MS) that can separate intact proteins. Hydrophilic interaction liquid chromatography (HILIC) has recently shown good potential for the characterization of glycoforms of intact proteins. In the present study, we demonstrate that HILIC can separate a wide range of proteins exhibiting orthogonal selectivity with respect to reversed-phase LC (RPLC). However, the application of HILIC to the analysis of low abundance proteins (e.g., in proteomics analysis) is hampered by low volume loadability, hindering down-scaling of the method to column diameters below 2.1 mm. Moreover, HILIC-MS sensitivity is decreased due to ion suppression from the trifluoroacetic acid (TFA) often used as the ion-pair agent to improve the selectivity and efficiency in the analysis of glycoproteins. Here, we introduce a capillary-based HILIC-MS method that overcomes these problems. Our method uses RPLC trap-columns to load and inject the sample, circumventing issues of protein solubility and volume loadability in capillary columns (200 mu m ID). The low flow rates and use of a dopant gas in the electrospray interface improve protein-ionization efficiencies and reduce suppression by TFA. Overall, this allows the separation and detection of small protein quantities (down to 5 ng injected on column) as indicated by the analysis of a mixture of model proteins. The potential of the new capillary HILIC-MS is demonstrated by the analysis of a complex cell lysate. Show less