BackgroundLymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted... Show moreBackgroundLymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-Tc-99m-nanoscan compared to ICG-Tc-99m-nanocolloid from a nuclear and surgical perspective.MethodsTwenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-Tc-99m-nanocolloid until no longer available; the second group (n = 13) received ICG-Tc-99m-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors.ResultsThe mean tracer uptake in the SNs was similar for ICG-Tc-99m-nanocolloid (2.2 +/- 4.3%ID) and ICG-Tc-99m-nanoscan (1.8 +/- 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-Tc-99m-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-Tc-99m-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-Tc-99m-nanoscan group (24*10(9) arbitrary units (A.U) IQR 1.6*10(9)-14*10(9) in the ICG-Tc-99m-nanocolloid group versus 4.6*10(9) A.U. IQR 2.4*10(9)-42*10(9) in the ICG-Tc-99m-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported.ConclusionsBased on this retrospective analysis, we can conclude that ICG-Tc-99m-nanoscan has similar capacity for SN identification as ICG-Tc-99m-nanocolloid and can safely be implemented in SN procedures. Show less
Rietbergen, D.D.D.; Gennep, E.J. van; KleinJan, G.H.; Donswijk, M.; Olmos, R.A.V.; Rhijn, B.W. van; ... ; Leeuwen, F.W.B. van 2022
Rationale: In muscle-invasive bladder cancer (MIBC), lymph node invasion has proven to be an independent predictor of disease recurrence and cancer-specific survival. We evaluated the feasibility... Show moreRationale: In muscle-invasive bladder cancer (MIBC), lymph node invasion has proven to be an independent predictor of disease recurrence and cancer-specific survival. We evaluated the feasibility of targeting the sentinel node (SN) for biopsy in MIBC patients using the hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid for simultaneous radioguidance and fluorescence guidance. Methods: Twenty histologically confirmed cN0M0 MIBC patients (mean age, 63.3 years; range, 30-82 years), scheduled for radical cystectomy with SN biopsy and extended pelvic lymph node dissection (ePLND), were prospectively included. Twelve patients were operated on following neoadjuvant chemotherapy. The patients received lymphoscintigraphy as well as SPECT/CT after 4 transurethral injections of ICG-Tc-99m-nanocolloid (mean, 208 MBq; range, 172-229 MBq) around the tumor/scar in the detrusor muscle of the bladder on the day before radical cystectomy. Sentinel node resection was performed under radioguidance and fluorescence guidance. Results: Nineteen patients could be analyzed. On preoperative imaging, SNs could be identified in 10 patients (53%; mean, 1.6 SN/patient), which revealed drainage pathways outside the ePLND in 20% of the patients. Interesting to note is that 2 patients (10%) with preoperative nonvisualization displayed fluorescent and radioactive SNs during surgery. Location of the primary tumor near the left lateral side of the bladder seemed to be a factor for nonvisualization. Nodal harvesting with ePLND varied among patients (mean, 23.3). Histopathology confirmed tumor-positive nodes in 4 (21%) of all patients. In the 2 patients where an SN could be identified, the ePLND specimens were tumor-negative. All patients with tumor-positive nodes had advanced disease (stage III). Conclusion: Sentinel node biopsy in bladder cancer using the hybrid tracer ICG-Tc-99m-nanocolloid is feasible, and preoperative imaging is predictive for the ability to perform SN biopsy in 83% of the patients who displayed an SN. In patients with a successful preoperative SN mapping using lymphoscintigraphy and SPECT/CT, the intraoperative SN guidance and detection were effective, even outside the ePLND area. As such, this study underscores the critical role that preoperative imaging plays in challenging image-guided surgery applications. Show less
Mazzone, E.; Dell'Oglio, P.; Grivas, N.; Wit, E.; Donswijk, M.; Briganti, A.; ... ; Poel, H. van der 2021
Despite good sensitivity and a good negative predictive value, the implementation of sentinel node biopsy (SNB) in robot-assisted radical prostatectomy with extended pelvic lymph node dissection ... Show moreDespite good sensitivity and a good negative predictive value, the implementation of sentinel node biopsy (SNB) in robot-assisted radical prostatectomy with extended pelvic lymph node dissection (ePLND) for prostate cancer is still controversial. For this reason, we aimed to define the added value of SNB (with different tracer modalities) to ePLND in the identification of nodal metastases. Complication rates and oncologic outcomes were also assessed. Methods: From January 2006 to December 2019, prospectively collected data were retrospectively analyzed from a single-institution database regarding prostate cancer patients treated with robot-assisted radical prostatectomy and ePLND with or without additional use of SNB, either with the hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid or with free ICG. Multivariable logistic and Cox regression models tested the impact of adding SNB (either with the hybrid tracer or with free ICG) on lymph nodal invasion detection, complications, and oncologic outcomes. Results: Overall, 1,680 patients were included in the final analysis: 1,168 (69.5%) in the non-SNB group, 161 (9.6%) in the ICG-SNB group, and 351 (20.9%) in the hybrid-SNB group. The hybrid-SNB group (odds ratio, 1.61; 95%CI, 1.18-2.20; P = 0.002) was an independent predictor of nodal involvement, whereas the ICG-SNB group did not reach independent predictor status when compared with the non-SNB group (odds ratio, 1.35; 95%CI, 0.89-2.03; P = 0.1). SNB techniques were not associated with higher rates of complications. Lastly, use of hybrid SNB was associated with lower rates of biochemical recurrence (0.79; 95%CI, 0.63-0.98) and of clinical recurrence (hazard ratio, 0.76, P = 0.035) than were seen in the non-SNB group. Conclusion: The implementation of hybrid-SNB technique with ICG-Tc-99m-nanocolloid in prostate cancer improves detection of positive nodes and potentially lowers recurrence rates with subsequent optimization of patient management, without harming patient safety. Show less
Dell'Oglio, P.; Mazzone, E.; Grivas, N.; Wit, E.; Donswijk, M.; Briganti, A.; ... ; Poel, H. van der 2021
Despite good sensitivity and a good negative predictive value, the implementation of sentinel node biopsy (SNB) in robot-assisted radical prostatectomy with extended pelvic lymph node dissection ... Show moreDespite good sensitivity and a good negative predictive value, the implementation of sentinel node biopsy (SNB) in robot-assisted radical prostatectomy with extended pelvic lymph node dissection (ePLND) for prostate cancer is still controversial. For this reason, we aimed to define the added value of SNB (with different tracer modalities) to ePLND in the identification of nodal metastases. Complication rates and oncologic outcomes were also assessed. Methods: From January 2006 to December 2019, prospectively collected data were retrospectively analyzed from a single-institution database regarding prostate cancer patients treated with robot-assisted radical prostatectomy and ePLND with or without additional use of SNB, either with the hybrid tracer indocyanine green (ICG)–99mTc-nanocolloid or with free ICG. Multivariable logistic and Cox regression models tested the impact of adding SNB (either with the hybrid tracer or with free ICG) on lymph nodal invasion detection, complications, and oncologic outcomes. Results: Overall, 1,680 patients were included in the final analysis: 1,168 (69.5%) in the non-SNB group, 161 (9.6%) in the ICG-SNB group, and 351 (20.9%) in the hybrid-SNB group. The hybrid-SNB group (odds ratio, 1.61; 95%CI, 1.18–2.20; P = 0.002) was an independent predictor of nodal involvement, whereas the ICG-SNB group did not reach independent predictor status when compared with the non-SNB group (odds ratio, 1.35; 95%CI, 0.89–2.03; P = 0.1). SNB techniques were not associated with higher rates of complications. Lastly, use of hybrid SNB was associated with lower rates of biochemical recurrence (0.79; 95%CI, 0.63–0.98) and of clinical recurrence (hazard ratio, 0.76, P = 0.035) than were seen in the non-SNB group. Conclusion: The implementation of hybrid-SNB technique with ICG–99mTc-nanocolloid in prostate cancer improves detection of positive nodes and potentially lowers recurrence rates with subsequent optimization of patient management, without harming patient safety. Show less
Rietbergen, D.D.D.; Meershoek, P.; Kleinjan, G.H.; Donswijk, M.; Olmos, R.A.V.; Leeuwen, F.W.B. van; ... ; Hage, J.A. van der 2020
Objective The hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid has been introduced for sentinel node imaging. However, until now, a comparison of this tracer with other radiocolloids with a... Show moreObjective The hybrid tracer indocyanine green (ICG)-Tc-99m-nanocolloid has been introduced for sentinel node imaging. However, until now, a comparison of this tracer with other radiocolloids with a larger particle size has not been effectuated. Based on a head-to-head evaluation in patients with melanoma, we have compared ICG-Tc-99m-nanocolloid (particle size 5-80 nm) with(99m)Tc-Senti-Scint (particle size 100-600 nm) to establish differences in drainage pattern and sentinel node localization using lymphoscintigraphy and single-photon emission computed tomography combined with computer tomography (SPECT-CT) in melanoma patients scheduled for sentinel node biopsy. Methods Twenty-five patients (mean age: 56.9 years, range: 25-79 years) with a melanoma scheduled for SLN biopsy prior to (re)excision of the primary lesion (scar) were prospectively included following a two-day procedure. The first day, after(99m)Tc-Senti-Scint injection in four intradermal depots around the primary lesion or scar, early/delayed lymphoscintigraphy and SPECT-CT images were acquired. The injection sites were marked. The second day, after assessing lymph node radioactivity using planar scintigraphy, ICG-Tc-99m-nanocolloid was injected at the previously marked skin points and imaging was performed. The paired planar and SPECT-CT images of both tracers were evaluated with respect to drainage patterns, SLN visualization and non-SLN appearing. Results Twenty-four out of 25 patients were evaluable. SLN visualization on a patient basis was 100% for ICG-Tc-99m-nanocolloid and 96% for(99m)Tc-Senti-Scint, whereas uptake in non-SLNs was found in, respectively, 71% (17/24) and 61% (14/23). Concordance in drainage to 45 lymph node basins was 91%. Discordant drainage was found for two melanomas in the head-and-neck and one in the clavicular area. Unique lymph node basins were seen in 44/45 (98%) for ICG-Tc-99m-nanocolloid and 42/45 (93%) for(99m)Tc-Senti-Scint. Concerning identified SLNs, the number was similar for both tracers (n = 58); however, more non-SLNs (65 vs 50) were visualized with ICG-Tc-99m-nanocolloid than with(99m)Tc-Senti-Scint. Conclusion A slightly higher SLN visualization accompanied by a tendency to depict more non-SLNs was found for ICG-Tc-99m-nanocolloid. Excepting the head and neck area, an overall high concordance in drainage was found for both radiotracers. With an additional value for the hybrid tracer due to the combination of preoperative imaging and the additional visual signal in the operation room, added by the fluorescent component of the hybrid tracer, there was a preference for ICG-Tc-99m-nanocolloid. Show less