Objective To assess the predictive value of tidal volume (Vt) of spontaneous breaths at birth in infants with congenital diaphragmatic hernia (CDH).Design Prospective study.Setting Tertiary... Show moreObjective To assess the predictive value of tidal volume (Vt) of spontaneous breaths at birth in infants with congenital diaphragmatic hernia (CDH).Design Prospective study.Setting Tertiary neonatal intensive care unit.Patients Thirty infants with antenatally diagnosed CDH born at Hospital Sant Joan de Deu in Barcelona from September 2013 to September 2015.Interventions Spontaneous breaths and inflations given in the first 10 min after intubation at birth were recorded using respiratory function monitor. Only expired Vt of uninterrupted spontaneous breaths was included for analysis. Receiver operating characteristics (ROC) analysis was performed and the area under the curve (AUC) was estimated to assess the predictive accuracy of Vt.Main outcome measures Mortality before hospital discharge and chronic lung disease (CLD) at day 28 of life.Results There were 1.233 uninterrupted spontaneous breaths measured, and the overall mean Vt was 2.8 +/- 2.1 mL/kg. A lower Vt was found in infants who died (n=14) compared with survivors (n=16) (1.7 +/- 1.6 vs 3.7 +/- 2.1 mL/kg; p=0.008). Vt was lower in infants who died during admission or had CLD (n=20) compared with survivors without CLD (n=10) (2.0 +/- 1.7 vs 4.3 +/- 2.2 mL/kg; p=0.004). ROC analysis showed that Vt <= 2.2 mL/kg predicted mortality with 79% sensitivity and 81% specificity (AUC=0.77, p=0.013). Vt <= 3.4 mL/kg was a good predictor of death or CLD (AUC=0.80, p=0.008) with 85% sensitivity and 70% specificity.Conclusion Vt of spontaneous breaths measured immediately after birth is associated with mortality and CLD. Vt seems to be a reliable predictor but is not an independent predictor after adjustment for observed/expected lung to head ratio and liver position. Show less
Knol, R.; Brouwer, E.; Akker, T. van den; DeKoninck, P.; Geloven, N. van; Polglase, G.R.; ... ; Pas, A.B. te 2020
Aim: To test whether stabilising very preterm infants while performing physiological-based cord clamping (PBCC) is at least as effective as the standard approach of time-based delayed cord clamping... Show moreAim: To test whether stabilising very preterm infants while performing physiological-based cord clamping (PBCC) is at least as effective as the standard approach of time-based delayed cord clamping (DCC).Methods: A randomised controlled non-inferiority study was performed in two centres from May until November 2018, including preterm infants born below 32 weeks of gestational age. Infants were allocated to PBCC or standard DCC. Infants receiving PBCC were stabilised on a purpose-built resuscitation table with an intact umbilical cord. The cord was clamped when the infant had regular spontaneous breathing, heart rate >= 100 bpm and SpO(2) 90% while using FiO(2) 0.40. In infants receiving DCC, the cord was clamped at 30 60 seconds after birth before they were transferred to the standard resuscitation table for further treatment and stabilisation. Primary outcome was time to reach respiratory stability.Results: Thirty-seven infants (mean gestational age 29+0 weeks) were included. Mean cord clamping time was 5:49 +/- 2:37 min in the PBCC (n = 20) and 1:02 +/- 0:30 min in the DCC group (n = 17). Infants receiving PBCC needed less time to reach respiratory stability (PBCC 5:54 +/- 2:27 min; DCC 7:07 +/- 2:54 min; mean difference corrected for gestational age 1:19 min, 95 degrees 6 CI [3:04 0:27]), showing non-inferiority with the pre-defined limit of 1:15 min. No significant differences between the groups were found for maternal blood loss, postpartum haemorrhage, infant temperature at admission or short-term neonatal outcomes.Conclusion: Stabilisation of very preterm infants with physiological-based cord clamping is at least as effective as with standard DCC. Show less
Brouwer, E.; Knol, R.; Vernooij, A.S.N.; Akker, T. van den; Vlasman, P.E.; Klumper, F.J.C.M.; ... ; Pas, A.B. te 2019