The diagnostic performance of a prospective, systematic screening strategy for COVID-19 associated pulmonary aspergillosis (CAPA) during the COVID-19 pandemic was investigated. Patients with COVID... Show moreThe diagnostic performance of a prospective, systematic screening strategy for COVID-19 associated pulmonary aspergillosis (CAPA) during the COVID-19 pandemic was investigated. Patients with COVID-19 admitted to the ICU were screened for CAPA twice weekly by collection of tracheal aspirate (TA) for Aspergillus culture and PCR. Subsequently, bronchoalveolar lavage (BAL) sampling was performed in patients with positive screening results and clinical suspicion of infection. Patient data were collected from April 2020–February 2022. Patients were classified according to 2020 ECMM/ISHAM consensus criteria. In total, 126/370 (34%) patients were positive in screening and CAPA frequency was 52/370 (14%) (including 13 patients negative in screening). CAPA was confirmed in 32/43 (74%) screening positive patients who underwent BAL sampling. ICU mortality was 62% in patients with positive screening and confirmed CAPA, and 31% in CAPA cases who were screening negative. The sensitivity, specificity, positive and negative predictive value (PPV & NPV) of screening for CAPA were 0.71, 0.73, 0.27, and 0.95, respectively. The PPV was higher if screening was culture positive compared to PCR positive only, 0.42 and 0.12 respectively. CAPA was confirmed in 74% of screening positive patients, and culture of TA had a better diagnostic performance than PCR. Positive screening along with clinical manifestations appeared to be a good indication for BAL sampling since diagnosis of CAPA was confirmed in most of these patients. Prospective, systematic screening allowed to quickly gain insight into the epidemiology of fungal superinfections during the pandemic and could be applicable for future pandemics. Show less
Arends, E.J.; Meziyerh, S.; Moes, D.J.A.R.; Kamerling, S.W.A.; Kooy, S. van der; Ogando, N.S.; ... ; Teng, Y.K.O. 2023
Introduction: Immunocompromised kidney patients are at increased risk of prolonged SARS-CoV-2 infection and related complications. Preclinical evidence demonstrates a more potent inhibitory effect... Show moreIntroduction: Immunocompromised kidney patients are at increased risk of prolonged SARS-CoV-2 infection and related complications. Preclinical evidence demonstrates a more potent inhibitory effect of voclosporin on SARS-CoV-2 replication than tacrolimus in vitro. We investigated the potential antiviral effects of voclosporin on SARS-CoV-2 in immunocompromised patients.Methods: First, we conducted a prospective, randomized, open-label, proof-of-concept study in 20 kidney transplant recipients (KTRs) on tacrolimus-based immunosuppression who contracted mild to moderate SARS-CoV-2 infection. Patients were randomized to continue tacrolimus or switch to voclosporin. Second, we performed a post hoc analysis on SARS-CoV-2 infections in 216 patients with lupus nephritis (LN) on standard immunosuppression who were randomly exposed to voclosporin or placebo as part of a clinical trial that was conducted during the worldwide COVID-19 pandemic. Results: The primary end point was clearance of SARS-CoV-2 viral load and that did not differ between voclosporin-treated KTRs (median 12 days, interquartile range [IQR] 8-28) and tacrolimus-treated KTRs (median 12 days, IQR 4-16) nor was there a difference in clinical recovery. Pharmacokinetic analyses demonstrated that, when voclosporin trough levels were on-target, SARS-CoV-2 viral load dropped significantly more (DCt 7.7 [3.4-10.7]) compared to tacrolimus-treated KTRs (DCt 2.7 [2.0-4.3]; P 1/4 0.035). In voclosporin-exposed patients with LN, SARS-CoV-2 infection was detected in 6% (7/116) compared to 12% (12/100) in placebo-exposed patients (relative risk [RR] 1.4 [0.97-2.06]). Notably, no voclosporin-exposed patients with LN died from severe SARS-CoV-2 infection compared to 3% (3/100) in placebo-exposed patients (RR 2.2 [1.90-2.54]).Conclusion: This proof-of-concept study shows a potential positive risk-benefit profile for voclosporin in immunocompromised patients with SARS-CoV-2 infection. These results warrant further investigations on voclosporin to establish an equipoise between infection and maintenance immunosuppression. Show less
The recently observed increase in invasive Streptococcus pyogenes infections causes concern in Europe. However, conventional molecular typing methods lack discriminatory power to aid... Show moreThe recently observed increase in invasive Streptococcus pyogenes infections causes concern in Europe. However, conventional molecular typing methods lack discriminatory power to aid investigations of outbreaks caused by S. pyogenes. Therefore, there is an urgent need for high-resolution molecular typing methods to assess genetic relatedness between S. pyogenes isolates. In the current study, we aimed to develop a novel high-resolution core-genome multilocus sequence typing (cgMLST) scheme for S. pyogenes and compared its discriminatory power to conventional molecular typing methods. The cgMLST scheme was designed with the commercial Ridom SeqSphere+ software package. To define a cluster threshold, the scheme was evaluated using publicly available data from nine defined S. pyogenes outbreaks in the United Kingdom. The cgMLST scheme was then applied to 23 isolates from a suspected S. pyogenes outbreak and 117 S. pyogenes surveillance isolates both from the Netherlands. MLST and emm-typing results were used for comparison to cgMLST results. The allelic differences between isolates from defined outbreaks ranged between 6 and 31 for isolates with the same emm-type, resulting in a proposed cluster threshold of <5 allelic differences out of 1,095 target loci. Seven out of twenty-three (30%) isolates from the suspected outbreak had an allelic difference of <2, thereby identifying a potential cluster that could not be linked to other isolates. The proposed cgMLST scheme shows a higher discriminatory ability when compared to conventional typing methods. The rapid and simple analysis workflow allows for extended detection of clusters of potential outbreak isolates and surveillance and may facilitate the sharing of sequencing results between (inter)national laboratories. Show less
Lee, M.E.; Albert, E.; Wessels, E.; Kim, S.K.; Chung, H.S.; Gimenez, E.; ... ; Navarro, D. 2023
Monitoring of cytomegalovirus (CMV) viral load is critical for informing treatment decisions in order to prevent the severe health consequences of CMV infection or reactivation of latent CMV in... Show moreMonitoring of cytomegalovirus (CMV) viral load is critical for informing treatment decisions in order to prevent the severe health consequences of CMV infection or reactivation of latent CMV in immunocompromised individuals. This first field evaluation examined the analytical and clinical performance of the Alinity m CMV assay. Analytical performance was assessed with a commercially available six-member panel, while the clinical performance evaluation compared the Alinity m CMV assay to the RealTime CMV assay and a laboratory-developed test (LDT) as the test of record at three large hospital-based clinical laboratories. Precision of the Alinity m CMV assay was demonstrated with total standard deviation (SD) between 0.08 and 0.28 Log IU/mL. A total of 457 plasma specimens were tested on the Alinity m CMV assay and compared to the test of record at each site (n = 304 with RealTime CMV and n = 153 with LDT CMV). The Alinity m CMV assay had excellent correlation (correlation coefficient r =0.942) in comparison to the RealTime CMV or LDT CMV assays. The mean observed bias ranged from -0.03 to 0.34 Log IU/mL. Median onboard turnaround time of Alinity m CMV was less than 3 h. When the CMV assay is run on the Alinity m system, it has the capacity to shorten time to result and, therefore, to therapy. Show less
Detection and monitoring of acute infection or reactivation of Epstein-Barr virus (EBV) are critical for treatment decision-making and to reduce the risk of EBV-related malignancies and other... Show moreDetection and monitoring of acute infection or reactivation of Epstein-Barr virus (EBV) are critical for treatment decision-making and to reduce the risk of EBV-related malignancies and other associated diseases in immunocompromised individuals. The analytical and clinical performance of the Alinity m EBV assay was evaluated at two independent study sites; analytical performance was assessed by evaluating precision with a commercially available 5-member EBV verification panel, while the clinical performance of the Alinity m EBV assay was compared to the RealTime EBV assay and a laboratory-developed test (LDT) as the routine test of record (TOR). Analytical analysis demonstrated standard deviation (SD) between 0.08 and 0.13 Log IU/mL. A total of 300 remnant plasma specimens were retested with the Alinity m EBV assay, and results were compared to those of the TOR at the respective study sites (n = 148 with the RealTime EBV assay and n = 152 with the LDT EBV assay). Agreement between Alinity m EBV and RealTime EBV or LDT EBV assays had kappa values of 0.88 and 0.84, respectively, with correlation coefficients r of 0.956 and 0.912, while the corresponding observed mean bias was -0.02 and -0.19 Log IU/mL. The Alinity m EBV assay had a short median onboard turnaround time of 2:40 h. Thus, the Alinity m system can shorten the time to results and, therefore, to therapy. Show less
Background: Viral load (VL) determination in patients with human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) is essential for proper patient... Show moreBackground: Viral load (VL) determination in patients with human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) is essential for proper patient management and follow-up. New molecular platforms have been developed to fully automate these diagnostic assays.Objective: Evaluation of the clinical performance of HIV-1, HBV and HCV VL assays on the Alinity m (Abbott) and NeuMoDx (Qiagen) molecular platforms.Method: Test panels of the three viruses have been compiled of 100 plasma and/or serum samples per target containing non-detectable, non-quantifiable and quantifiable VLs. All samples were retrospectively tested on the Alinity m and NeuMoDx platforms according to manufacturers' instructions. Results: A total of 74, 86 and 66 samples with valid results for both platforms were included in the HIV-1, HBV and HCV analysis respectively. Overall qualitative agreement of the assays on both platforms was 78% for HIV-1, 93% for HBV and 100% for HCV. Quantitative agreement (less than 0.5 log difference) was shown to be 68% for HIV-1, 68% for HBV and 94% for HCV.Conclusion: The Alinity m and NeuMoDx HCV assay have a comparable performance. Quantification differences in the HIV-1 assay were mostly apparent in the lower VLs and under-quantification of the NeuMoDx HBV assay was observed. Show less
Objectives: While Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA), defined as CC398, is a well-known pathogen among those working with livestock, there are indications... Show moreObjectives: While Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA), defined as CC398, is a well-known pathogen among those working with livestock, there are indications that LA-MRSA prevalence among the general population is increasing. However, the clinical impact in urban areas remains unknown. The aim of this study was to assess the genetic epidemiology and clinical characteristics of LA-MRSA in an urban area with a limited livestock population. Methods: In this retrospective study, we evaluated LA-MRSA strains that were collected between 2014 and 2018 from patients who received clinical care in a single urban area in Netherlands. Patient files were assessed for livestock exposure data, clinical findings, and contact tracing information. Next-generation sequencing (NGS) analysis in combination with wgMLST was conducted to assess genetic diversity and relatedness and to detect virulence and resistance genes. Results: LA-MRSA strains were cultured from 81 patients, comprising 12% of all the MRSA strains found in seven study laboratories between 2014 and 2018. No livestock link was found in 76% of patients (n = 61), and 28% of patients (n = 23) had an infection, mostly of the skin or soft tissue. Contact tracing had been initiated in 14 cases, leading to the identification of two hospital transmissions: a cluster of 9 cases and one of 2 cases. NGS data were available for 91% (n = 75) of the patients. wgMLST confirmed the clusters detected via contact tracing (n = 2) and identified 5 additional clusters without a known epidemiological link. Relevant resistance and virulence findings included the PVL virulence gene (3 isolates) and tetracycline resistance (79 isolates). Conclusion: LA-MRSA may cause a relevant burden of disease in urban areas. Surprisingly, most infections in the present study occurred in the absence of a livestock link, suggesting inter-human transmission. These findings and the presence of PVL and other immune evasive complex virulence genes warrant future surveillance and preventative measures. Show less
Objectives: While Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA), defined as CC398, is a well-known pathogen among those working with livestock, there are indications... Show moreObjectives: While Livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA), defined as CC398, is a well-known pathogen among those working with livestock, there are indications that LA-MRSA prevalence among the general population is increasing. However, the clinical impact in urban areas remains unknown. The aim of this study was to assess the genetic epidemiology and clinical characteristics of LA-MRSA in an urban area with a limited livestock population.Methods: In this retrospective study, we evaluated LA-MRSA strains that were collected between 2014 and 2018 from patients who received clinical care in a single urban area in Netherlands. Patient files were assessed for livestock exposure data, clinical findings, and contact tracing information. Next-generation sequencing (NGS) analysis in combination with wgMLST was conducted to assess genetic diversity and relatedness and to detect virulence and resistance genes.Results: LA-MRSA strains were cultured from 81 patients, comprising 12% of all the MRSA strains found in seven study laboratories between 2014 and 2018. No livestock link was found in 76% of patients (n = 61), and 28% of patients (n = 23) had an infection, mostly of the skin or soft tissue. Contact tracing had been initiated in 14 cases, leading to the identification of two hospital transmissions: a cluster of 9 cases and one of 2 cases. NGS data were available for 91% (n = 75) of the patients. wgMLST confirmed the clusters detected via contact tracing (n = 2) and identified 5 additional clusters without a known epidemiological link. Relevant resistance and virulence findings included the PVL virulence gene (3 isolates) and tetracycline resistance (79 isolates).Conclusion: LA-MRSA may cause a relevant burden of disease in urban areas. Surprisingly, most infections in the present study occurred in the absence of a livestock link, suggesting inter-human transmission. These findings and the presence of PVL and other immune evasive complex virulence genes warrant future surveillance and preventative measures. Show less
Background: The detection and follow up of cytomegalovirus (CMV) and Epstein-Barr virus (EBV) viral loads (VL) are crucial in the management of immunocompromised patients. Recently, molecular CE... Show moreBackground: The detection and follow up of cytomegalovirus (CMV) and Epstein-Barr virus (EBV) viral loads (VL) are crucial in the management of immunocompromised patients. Recently, molecular CE-IVD assays for detection and quantification of CMV and EBV have been launched for use on the random-access and sample-to-result NeuMoDx 96 and 288 platforms (Qiagen). Objective: Evaluating the qualitative and quantitative performance of the NeuMoDx CMV and EBV assays in clinical specimens compared to a lab developed tests (LDT) and the CE-IVD assays on the Abbott m2000 system. Method: Both a prospective and a retrospective panel, compiled of non-detectable (ND), non-quantifiable (NQ) and quantifiable VLs in plasma samples have been evaluated for both CMV and EBV: NeuMoDx versus LDT and NeuMoDx versus Abbott m2000. Quantitative agreement was determined for samples with a quantifiable VL on both systems. Results: Qualitative and quantitative agreement between the NeuMoDx and LUMC's LDT CMV assays was 88%. Qualitative agreement between the NeuMoDx and Abbott m2000 CMV assays was 92% and quantitative agreement was 87%. Qualitative and quantitative agreement between the NeuMoDx and the LDT EBV assays was 87%. Qualitative agreement between the NeuMoDx and Abbott m2000 EBV assays was 91% and quantitative agreement was 0%. Conclusion: These data show that the NeuMoDx assays are suitable for both detection and quantification of CMV and EBV in a medium-to high throughput diagnostic setting, but that differences in sensitivity and quantification (for EBV, NeuMoDx versus Abbott m2000) warrant an extensive transition period when using the respective assays for following VL in patient samples. Show less
Carbo, E.C.; Sidorov, I.A.; Rijn-Klink, A.L. van; Pappas, N.; Boheemen, S. van; Mei, H.L.; ... ; Vries, J.J.C. de 2022
Viral metagenomics is increasingly applied in clinical diagnostic settings for detection of pathogenic viruses. While several benchmarking studies have been published on the use of metagenomic... Show moreViral metagenomics is increasingly applied in clinical diagnostic settings for detection of pathogenic viruses. While several benchmarking studies have been published on the use of metagenomic classifiers for abundance and diversity profiling of bacterial populations, studies on the comparative performance of the classifiers for virus pathogen detection are scarce. In this study, metagenomic data sets (n = 88) from a clinical cohort of patients with respiratory complaints were used for comparison of the performance of five taxonomic classifiers: Centrifuge, Clark, Kaiju, Kraken2, and Genome Detective. A total of 1144 positive and negative PCR results for a total of 13 respiratory viruses were used as gold standard. Sensitivity and specificity of these classifiers ranged from 83 to 100% and 90 to 99%, respectively, and was dependent on the classification level and data pre-processing. Exclusion of human reads generally resulted in increased specificity. Normalization of read counts for genome length resulted in a minor effect on overall performance, however it negatively affected the detection of targets with read counts around detection level. Correlation of sequence read counts with PCR Ct-values varied per classifier, data pre-processing (R-2 range 15.1-63.4%), and per virus, with outliers up to 3 log(10) reads magnitude beyond the predicted read count for viruses with high sequence diversity. In this benchmarking study, sensitivity and specificity were within the ranges of use for diagnostic practice when the cut-off for defining a positive result was considered per classifier. Show less
Introduction: Immunocompromised patients are prone to reactivations and (re-)infections of multiple DNA viruses. Viral load monitoring by single-target quantitative PCRs (qPCR) is the current... Show moreIntroduction: Immunocompromised patients are prone to reactivations and (re-)infections of multiple DNA viruses. Viral load monitoring by single-target quantitative PCRs (qPCR) is the current cornerstone for virus quantification. In this study, a metagenomic next-generation sequencing (mNGS) approach was used for the identification and load monitoring of transplantation-related DNA viruses. Methods: Longitudinal plasma samples from six patients that were qPCR-positive for cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK polyomavirus (BKV), adenovirus (ADV), parvovirus B19 (B19V), and torque teno-virus (TTV) were sequenced using the quantitative metagenomic Galileo Viral Panel Solution (Arc Bio, LLC, Cambridge, MA, USA) reagents and bioinformatics pipeline combination. Qualitative and quantitative performance was analysed with a focus on viral load ranges relevant for clinical decision making. Results: All pathogens identified by qPCR were also identified by mNGS. BKV, CMV, and HHV6B were additionally detected by mNGS, and could be confirmed by qPCR or auxiliary bioinformatic analysis. Viral loads determined by mNGS correlated with the qPCR results, with inter-method differences in viral load per virus ranging from 0.19 log(10) IU/mL for EBV to 0.90 log(10) copies/mL for ADV. TTV, analysed by mNGS in a semiquantitative way, demonstrated a mean difference of 3.0 log(10) copies/mL. Trends over time in viral load determined by mNGS and qPCR were comparable, and clinical thresholds for initiation of treatment were equally identified by mNGS. Conclusions: The Galileo Viral Panel for quantitative mNGS performed comparably to qPCR concerning detection and viral load determination, within clinically relevant ranges of patient management algorithms. Show less
Wegner, F.; Roloff, T.; Huber, M.; Cordey, S.; Ramette, A.; Gerth, Y.; ... ; Egli, A. 2022
This first pilot trial on external quality assessment (EQA) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) whole-genome sequencing, initiated by the European Society of Clinical... Show moreThis first pilot trial on external quality assessment (EQA) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) whole-genome sequencing, initiated by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) Study Group for Genomic and Molecular Diagnostics (ESGMD) and the Swiss Society for Microbiology (SSM), aims to build a framework between laboratories in order to improve pathogen surveillance sequencing. Ten samples with various viral loads were sent out to 15 clinical laboratories that had free choice of sequencing methods and bioinformatic analyses. The key aspects on which the individual centers were compared were the identification of (i) single nucleotide polymorphisms (SNPs) and indels, (ii) Pango lineages, and (iii) clusters between samples. The participating laboratories used a wide array of methods and analysis pipelines. Most were able to generate whole genomes for all samples. Genomes were sequenced to various depths (up to a 100-fold difference across centers). There was a very good consensus regarding the majority of reporting criteria, but there were a few discrepancies in lineage and cluster assignments. Additionally, there were inconsistencies in variant calling. The main reasons for discrepancies were missing data, bioinformatic choices, and interpretation of data. The pilot EQA was overall a success. It was able to show the high quality of participating laboratories and provide valuable feedback in cases where problems occurred, thereby improving the sequencing setup of laboratories. A larger follow-up EQA should, however, improve on defining the variables and format of the report. Additionally, contamination and/or minority variants should be a further aspect of assessment. Show less
At the time SARS-CoV-2 was identified as the cause of coronavirus disease 2019 (COVID-19) no in vitro diagnostic (IVD) tests were available since it was a new virus. Very shortly after the release... Show moreAt the time SARS-CoV-2 was identified as the cause of coronavirus disease 2019 (COVID-19) no in vitro diagnostic (IVD) tests were available since it was a new virus. Very shortly after the release of the genomic sequence of SARS-CoV-2, laboratory-developed tests (LDTs) were developed, made available and implemented in several laboratories in the Netherlands and globally. In this study, the performance of an E-gene Sarbeco specific realtime reverse-transcriptase PCR (RT-PCR) was verified on the open modus of the geneLEAD VIII sample-to-answer platform. The results obtained from 134 clinical samples, of which 63 had been tested positive, showed almost complete concordance compared to the same PCR on the routine diagnostic systems and that was validated according to the national reference standard. The only discordant sample tested positive using the routine diagnostic workflow with a cycle threshold (CT) value of 37.7, while the sample tested negative using the geneLEAD VIII workflow. In addition, good performance was achieved in analyzing a blinded SARS-CoV-2 external quality assurance (EQA) panel. Implementation of the geneLEAD VIII platform as routine diagnostic tool resulted in testing 871 clinical samples with 115 positive results. In conclusion, the geneLEAD VIII SARSCoV-2 workflow presented in this study showed excellent diagnostic performance and with a rapid turnaround time of approximately two hours it proved a valuable option for STAT SARS-CoV-2 testing in the absence of (rapid, CE-IVD) point-of-care testing platforms. Show less
Introduction Meningoencephalitis patients are often severely impaired and benefit from early etiological diagnosis, though many cases remain without identified cause. Metagenomics as pathogen... Show moreIntroduction Meningoencephalitis patients are often severely impaired and benefit from early etiological diagnosis, though many cases remain without identified cause. Metagenomics as pathogen agnostic approach can result in additional etiological findings; however, the exact diagnostic yield when used as a secondary test remains unknown. Areas covered This review aims to highlight recent advances with regard to wet and dry lab methodologies of metagenomic testing and technical milestones that have been achieved. A selection of procedures currently applied in accredited diagnostic laboratories is described in more detail to illustrate best practices. Furthermore, a meta-analysis was performed to assess the additional diagnostic yield utilizing metagenomic sequencing in meningoencephalitis patients. Finally, the remaining challenges for successful widespread implementation of metagenomic sequencing for the diagnosis of meningoencephalitis are addressed in a future perspective. Expert opinion The last decade has shown major advances in technical possibilities for using mNGS in diagnostic settings including cloud-based analysis. An additional advance may be the current established infrastructure of platforms for bioinformatic analysis of SARS-CoV-2, which may assist to pave the way for global use of clinical metagenomics. Show less
Background: Diagnosis of infections in returning international travellers can be challenging because of the broad spectrum of potential infectious etiologies potentially involved. Viral metagenomic... Show moreBackground: Diagnosis of infections in returning international travellers can be challenging because of the broad spectrum of potential infectious etiologies potentially involved. Viral metagenomic next-generation sequencing (mNGS) has the potential to detect any virus present in a patient sample and is increasingly being used for difficult to diagnose cases. The aim of this study was to analyze the performance of mNGS for viral pathogen detection in the clinical setting of international travellers returning with febrile illness. Methods: Thirty-eight serum samples from international travellers returning with febrile illness and presenting at the outpatient clinic of the Leiden University Medical Center in the Netherlands in the time period 2015-2016 were selected retrospectively. Samples were processed for viral metagenomic sequencing using a probe panel capturing all known vertebrate viruses. Bioinformatic analysis was performed using Genome Detective software for metagenomic virus detection. Metagenomic virus findings were compared with viral pathogen detection using conventional methods. Results: In 8 out of the 38 patients (21%), a pathogenic virus was detected by mNGS. All viral pathogens detected by conventional assays were also detected by mNGS: dengue virus (n=4 patients), Epstein-Barr virus (n=2), hepatitis B virus (n=1). In addition, mNGS resulted in additional pathogenic findings in 2 patients (5%): dengue virus (n=1), and hepatitis C virus (n=1). Non-pathogenic viruses detected were: GB virus C (n=1) and torque teno viruses (n=3). High genome coverage and depth using capture probes enabled typing of the dengue viruses detected. Conclusions: Viral metagenomics has the potential to assist the detection of viral pathogens and co-infections in one step in international travellers with a febrile syndrome. Furthermore, viral enrichment by probes resulted in high genome coverage and depth which enabled dengue virus typing. Show less
Background The ePlex (R) and QIAstat-Dx (R) respiratory pathogen panels detect multiple respiratory pathogens, mainly viruses but also Legionella pneumophila, Mycoplasma pneumoniae and Bordetella... Show moreBackground The ePlex (R) and QIAstat-Dx (R) respiratory pathogen panels detect multiple respiratory pathogens, mainly viruses but also Legionella pneumophila, Mycoplasma pneumoniae and Bordetella pertussis. The assays have been marketed for use in nasopharyngeal swab specimens. For diagnosing bacterial pneumonia, lower respiratory tract (LRT) specimens are indicated. Aim of this study was to evaluate the performance of these syndromic panels for these three bacterial targets in samples from the LRT. Fifty-six specimens were collected from our repositories, five negative samples and fifty-one samples which had been previously tested positive with the routine diagnostic real-time PCR assays for Legionella spp. (N = 20), Bordetella spp. (N = 16) or M. pneumoniae (N = 15). Results The QIAstat-Dx Respiratory Panel V2 (RP) assay detected all of the L. pneumophila and B. pertussis positive samples but only 11/15 (73.3 %) of the M. pneumoniae targets. The ePlex Respiratory Pathogen Panel (RPP) assay detected 10/14 (71.4 %) of the L. pneumophila targets, 8/12 (66.7 %) of the B. pertussis positive samples and 13/15 (86.7 %) of the M. pneumoniae targets. Conclusions No false-positive results were reported for all three bacterial pathogens by both assays. The clinical performance of both assays depended highly on the bacterial load in the sample and the type of specimen under investigation. Show less
Introduction: Metagenomic sequencing is increasingly being used in clinical settings for difficult to diagnose cases. The performance of viral metagenomic protocols relies to a large extent on the... Show moreIntroduction: Metagenomic sequencing is increasingly being used in clinical settings for difficult to diagnose cases. The performance of viral metagenomic protocols relies to a large extent on the bioinformatic analysis. In this study, the European Society for Clinical Virology (ESCV) Network on NGS (ENNGS) initiated a benchmark of metagenomic pipelines currently used in clinical virological laboratories.Methods: Metagenomic datasets from 13 clinical samples from patients with encephalitis or viral respiratory infections characterized by PCR were selected. The datasets were analyzed with 13 different pipelines currently used in virological diagnostic laboratories of participating ENNGS members. The pipelines and classification tools were: Centrifuge, DAMIAN, DIAMOND, DNASTAR, FEVIR, Genome Detective, Jovian, MetaMIC, MetaMix,One Codex, RIEMS, VirMet, and Taxonomer. Performance, characteristics, clinical use, and user-friendliness of these pipelines were analyzed.Results: Overall, viral pathogens with high loads were detected by all the evaluated metagenomic pipelines. In contrast, lower abundance pathogens and mixed infections were only detected by 3/13 pipelines, namely DNASTAR, FEVIR, and MetaMix. Overall sensitivity ranged from 80% (10/13) to 100% (13/13 datasets). Overall positive predictive value ranged from 71-100%. The majority of the pipelines classified sequences based on nucleotide similarity (8/13), only a minority used amino acid similarity, and 6 of the 13 pipelines assembled sequences de novo. No clear differences in performance were detected that correlated with these classification approaches. Read counts of target viruses varied between the pipelines over a range of 2-3 log, indicating differences in limit of detection.Conclusion: A wide variety of viral metagenomic pipelines is currently used in the participating clinical diagnostic laboratories. Detection of low abundant viral pathogens and mixed infections remains a challenge, implicating the need for standardization and validation of metagenomic analysis for clinical diagnostic use. Future studies should address the selective effects due to the choice of different reference viral databases. Show less
In 2018, an upsurge in echovirus 30 (E30) infections was reported in Europe. We conducted a large-scale epidemiologic and evolutionary study of 1,329 E30 strains collected in 22 countries in Europe... Show moreIn 2018, an upsurge in echovirus 30 (E30) infections was reported in Europe. We conducted a large-scale epidemiologic and evolutionary study of 1,329 E30 strains collected in 22 countries in Europe during 2016-2018. Most E30 cases affected persons 0-4 years of age (29%) and 25-34 years of age (27%). Sequences were divided into 6 genetic clades (G1-G6). Most (53%) sequences belonged to G1, followed by G6 (23%), G2 (17%), G4 (4%), G3 (0.3%), and G5 (0.2%). Each clade encompassed unique individual recombinant forms; G1 and G4 displayed >= 2 unique recombinant forms. Rapid turnover of new clades and recombinant forms occurred over time. Clades G1 and G6 dominated in 2018, suggesting the E30 upsurge was caused by emergence of 2 distinct clades circulating in Europe. Investigation into the mechanisms behind the rapid turnover of E30 is crucial for clarifying the epidemiology and evolution of these enterovirus infections. Show less
Metagenomic next-generation sequencing (mNGS) is an untargeted technique for determination of microbial DNA/RNA sequences in a variety of sample types from patients with infectious syndromes. mNGS... Show moreMetagenomic next-generation sequencing (mNGS) is an untargeted technique for determination of microbial DNA/RNA sequences in a variety of sample types from patients with infectious syndromes. mNGS is still in its early stages of broader translation into clinical applications. To further support the development, implementation, optimization and standardization of mNGS procedures for virus diagnostics, the European Society for Clinical Virology (ESCV) Network on Next-Generation Sequencing (ENNGS) has been established. The aim of ENNGS is to bring together professionals involved in mNGS for viral diagnostics to share methodologies and experiences, and to develop application guidelines. Following the ENNGS publication Recommendations for the introduction of mNGS in clinical virology, part I: wet lab procedure in this journal, the current manuscript aims to provide practical recommendations for the bioinformatic analysis of mNGS data and reporting of results to clinicians. Show less