Aims We aimed to update the logistic clinical SYNTAX score to predict 2 year all-cause mortality after contemporary percutaneous coronary intervention (PCI).Methods and results We analyzed 15,883... Show moreAims We aimed to update the logistic clinical SYNTAX score to predict 2 year all-cause mortality after contemporary percutaneous coronary intervention (PCI).Methods and results We analyzed 15,883 patients in the GLOBAL LEADERS study who underwent PCI. The logistic clinical SYNTAX model was updated after imputing missing values by refitting the original model (refitted original model) and fitting an extended new model (new model, with, selection based on the Akaike Information Criterion). External validation was performed in 10,100 patients having PCI at Fu Wai hospital.Chronic obstructive pulmonary disease, prior stroke, current smoker, hemoglobin level, and white blood cell count were identified as additional independent predictors of 2 year all-cause mortality and included into the new model.The c-indexes of the original, refitted original and the new model in the derivation cohort were 0.74 (95% CI 0.72-0.76), 0.75 (95% CI 0.73-0.77), and 0.78 (95% CI 0.76-0.80), respectively. The c-index of the new model was lower in the validation cohort than in the derivation cohort, but still showed improved discriminative ability of the newly developed model (0.72; 95% CI 0.67-0.77) compared to the refitted original model (0.69; 95% CI 0.64-0.74). The models overestimated the observed 2 year all-cause mortality of 1.11% in the Chinese external validation cohort by 0.54 percentage points, indicating the need for calibration of the model to the Chinese patient population.Conclusions The new model of the logistic clinical SYNTAX score better predicts 2 year all-cause mortality after PCI than the original model. The new model could guide clinical decision making by risk stratifying patients undergoing PCI. Show less
Aims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES... Show moreAims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES) in porcine coronary arteries.Methods and results: In 15 non-atherosclerotic Yucatan mini pigs, the ArterioSorb (3.0/14 mm) and XIENCE (3.0/15 mm) were implanted in 25 and 15 vessels, respectively. Acute performance was evaluated by using quantitative coronary angiography (QCA) and optical coherence tomography (OCT). Following three-dimensional reconstruction of the coronary arteries, endothelial shear stress (ESS) was quantified using non-Newtonian steady-flow simulation. Acute recoil measured by QCA was comparable in the two aims. Post-procedural flow and scaffold/stent area by OCT did not differ between the two devices. ESS post procedure was comparable between ArterioSorb and XIENCE (2.21 +/- 1.97 vs 2.25 +/- 1.71 Pa, p=0.314).Conclusions: Acute recoil, luminal dimensions and ESS in the ArterioSorb oriented PLLA scaffold with thin struts of 95 mu m were comparable to those in the XIENCE metallic DES. Show less
OBJECTIVES The aim of this study was to investigate the impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) on clinical outcomes in patients with de novo 3-vessel... Show moreOBJECTIVES The aim of this study was to investigate the impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) on clinical outcomes in patients with de novo 3-vessel disease (3VD) treated with contemporary PCI.BACKGROUND The clinical impact of post-PCI QFR in patients treated with state-of-the-art PCI for de novo 3VD is undetermined.METHODS All vessels treated in the SYNTAX (SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery) II trial were retrospectively screened and analyzed for post-PCI QFR. The primary endpoint of this substudy was vessel-oriented composite endpoint (VOCE) at 2 years, defined as the composite of vessel-related cardiac death, vessel-related myocardial infarction, and target vessel revascularization. The receiver-operating characteristic curve was used to calculate the optimal cutoff value of post-PCI QFR for predicting 2-year VOCE. All the analyzable vessels were stratified on the basis of the optimal cutoff value.RESULTS A total of 968 vessels treated with PCI were screened. Post-PCIQFR was analyzable in 771 (79.6%) vessels. A total of 52 (6.7%) VOCEs occurredat 2 years. The mean value of post-PCIQFR was 0.91 +/- 0.07. The diagnostic performance of post-PCI QFR to predict 2-year VOCE was moderate (area under the curve: 0.702; 95% confidence interval: 0.633 to 0.772), with the optimal cutoff value of post-PCI QFR for predicting 2-year VOCE 0.91 (sensitivity 0.652, specificity 0.635). The incidence of 2-year VOCE in the vessels with post-PCIQFR<0.91 (n = 284) was significantly higher compared with vessels with post-PCI QFR >= 0.91 (n = 487) (12.0% vs. 3.7%; hazard ratio: 3.37; 95% confidence interval: 1.91 to 5.97; p < 0.001).CONCLUSIONS A higher post-PCI QFR value is associated with improved vessel-related clinical outcomes in state-of the art PCI practice for de novo 3VD. Achieving a post-PCI QFR value >= 0.91 in all treated vessels should be a target when treating de novo 3VD. These findings require confirmation in future prospective trials. (C) 2019 by the American College of Cardiology Foundation. Show less
Optical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to... Show moreOptical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to investigate the in-vivo effect of strut thickness and strut protrusion on endothelial wall shear stress (ESS) distribution in ArterioSorb Absorbable Drug-Eluting Scaffold (ArterioSorb) and Absorb everolimus-eluting Bioresorbable Vascular Scaffold (Absorb) devices that struts with similar morphology (quadratic structure) but different thickness. In three animals, six coronary arteries were treated with ArterioSorb. At different six animals, six coronary arteries were treated with Absorb. Following three-dimensional(3D) reconstruction of the coronary arteries, Newtonian steady flow simulation was performed and the ESS were estimated. Mixed effects models were used to compare ESS distribution in the two devices. There were 4591 struts in the analyzed 477 cross-sections in Absorb (strut thickness=157 mu m) and 3105 struts in 429 cross-sections in ArterioSorb (strut thickness=95 mu m) for the protrusion analysis. In cross-section level analysis, there was significant difference between the scaffolds in the protrusion distances. The protrusion was higher in Absorb (97% of the strut thickness) than in ArterioSorb (88% of the strut thickness). ESS was significantly higher in ArterioSorb (1.52 +/- 0.34Pa) than in Absorb (0.73 +/- 2.19Pa) (p=0.001). Low- and very-low ESS data were seen more often in Absorb than in ArterioSorb. ArterioSorb is associated with a more favorable ESS distribution compared to the Absorb. These differences should be attributed to different strut thickness/strut protrusion that has significant effect on shear stress distribution. Show less
OBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX ... Show moreOBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score derived from QFR (fSS(QFR)) on clinical outcomes.BACKGROUND The applicability of QFR in patients with 3-vessel disease and the feasibility of fSS(QFR) have not yet been investigated.METHODS All lesions interrogated using instantaneous wave-free ratio and/or fractional flow reserve in the SYNTAX II trial were retrospectively screened and analyzed for QFR. The diagnostic performance of QFR was investigated using hybrid wire-derived pressure assessment (instantaneous wave-free ratio and fractional flow reserve), used in the trial as a reference. Patients with analyzable QFR in 3 vessels were stratified according to fSS(QFR) to evaluate its clinical prognostic value on the basis of 2-year patient-oriented composite endpoint.RESULTS QFRs were analyzable in 71.0% of lesions (836 lesions). The diagnostic performance of QFR to predict binary wire-based ischemia was substantial (area under the curve 0.81, accuracy 73.8%), with a positive predictive value of 85.9%. Independent predictors of diagnostic discordance were lesions in side branches, involvement of bifurcation or trifurcation, and small vessel. According to the 2-year patient-oriented composite endpoint, fSS(QFR) reclassified 26.1% of the patients (36 of 138) in the high-to intermediate-risk group into the low-risk group appropriately (net reclassification improvement 0.32; p < 0.001). The area under the curve for fSS(QFR) to predict the 2-year patient-oriented composite endpoint was higher than that of the classic anatomic SYNTAX score (0.68 vs. 0.56; p = 0.002).CONCLUSIONS QFR demonstrated substantial applicability in patients with 3-vessel disease. The fSS(QFR) has the potential to further refine prognostic risk estimation compared with the classic anatomic SYNTAX score. (c) 2019 by the American College of Cardiology Foundation. Show less