To examine feasibility and reproducibility and to evaluate the cardiovascular response to an isometric handgrip exercise in low-risk pediatric population using Cardiovascular Magnetic Resonance... Show moreTo examine feasibility and reproducibility and to evaluate the cardiovascular response to an isometric handgrip exercise in low-risk pediatric population using Cardiovascular Magnetic Resonance measurements. In a subgroup of 207 children with a mean age of 16 years participating in a population-based prospective cohort study, children performed an isometric handgrip exercise. During rest and exercise, continuous heart rate and blood pressure were measured. Cardiovascular magnetic resonance (CMR) measurements included left ventricular mass, aortic distensibility and pulse wave velocity at rest and left ventricular end-diastolic and end-systolic volumes, ejection fraction, stroke volume and cardiac output during rest and exercise. 207 children had successful CMR measurements in rest and 184 during exercise. We observed good reproducibility for all cardiac measurements. Heart rate increased with a mean ± standard deviation of 42.6% ± 20.0 and blood pressure with 6.4% ± 7.0, 5.4% ± 6.1 and 11.0% ± 8.3 for systolic, diastolic and mean arterial blood pressure respectively (p-values < 0.05). During exercise, left ventricular end-diastolic and end-systolic volumes and cardiac output increased, whereas left ventricular ejection fraction slightly decreased (p-values < 0.05). Stroke volume did not change significantly. A sustained handgrip exercise of 7 min at 30–40% maximal voluntary contraction is a feasible exercise-test during CMR in a healthy pediatric population, which leads to significant changes in heart rate, blood pressure and functional measurements of the left ventricle in response to exercise. This approach offers great novel opportunities to detect subtle differences in cardiovascular health. Show less
Background: The ADVANCE registry is a large prospective study of outcomes and resource utilization in patients undergoing coronary computed tomography angiography (CCTA) and CT-based fractional... Show moreBackground: The ADVANCE registry is a large prospective study of outcomes and resource utilization in patients undergoing coronary computed tomography angiography (CCTA) and CT-based fractional flow reserve (FFRCT). As experience with new technologies and practices develops over time, we investigated temporal changes in the use of FERCT within the ADVANCE registry.Methods: 5083 patients with coronary artery disease (CAD) on CCTA were prospectively enrolled in the ADVANCE registry and were divided into 3 equally sized cohorts based on the temporal order of enrollment per site. Demographics, CCTA and FERCT findings, and clinical outcomes through 1-year follow-up, were recorded and compared between tertiles.Results: The number of patients with a >= 70% stenosis on CCTA was similar over time (33.6%, 30.9%, and 33.8% for cohort 1-3). The rate of positive FFRCT <= 0.80 was higher for cohorts 2 (67.3%) and 3 (74.6%) than for cohort 1 (57.1%, p < 0.001). Invasive FFR rates decreased from 25.8% to 22.4% between cohort 1 and 3 (p = 0.023). Moreover, patients with a FFRCT <= 0.80 were less frequently referred for invasive coronary angiography (ICA) (from 62.9% to 52.9%, p < 0.001), and underwent fewer revascularizations between cohort 1 and 3 (from 41.9% to 32.0%, p < 0.001). The prevalence of major events was low (1.2%) and similar between cohorts.Conclusions: Growing experience with FFRCT improved the likelihood of identifying hemodynamically significant CAD and safely reduced the need for ICA and revascularization in patients with anatomically significant disease even in the instance of an abnormal FFRCT. Show less
Faquir, N. el; Vollema, M.E.; Delgado, V.; Ren, B.; Spitzer, E.; Rasheed, M.; ... ; Mieghem, N.M. van 2020
Background The integration of computed tomography (CT)-derived left ventricular outflow tract area into the echocardiography-derived continuity equation results in the reclassification of a... Show moreBackground The integration of computed tomography (CT)-derived left ventricular outflow tract area into the echocardiography-derived continuity equation results in the reclassification of a significant proportion of patients with severe aortic stenosis (AS) into moderate AS based on aortic valve area indexed to body surface area determined by fusion imaging (fusion AVA(i)). The aim of this study was to evaluate AS severity by a fusion imaging technique in patients with low-gradient AS and to compare the clinical impact of reclassified moderate AS versus severe AS. Methods We included 359 consecutive patients who underwent transcatheter aortic valve implantation for low-gradient, severe AS at two academic institutions and created a joint database. The primary endpoint was a composite of all-cause mortality and rehospitalisations for heart failure at 1 year. Results Overall, 35% of the population (n= 126) were reclassified to moderate AS [median fusion AVAi 0.70 (interquartile range, IQR 0.65-0.80)cm(2)/m(2)] and severe AS was retained as the classification in 65% [median fusion AVAi 0.49 (IQR 0.43-0.54) cm(2)/m(2)]. Lower body mass index, higher logistic EuroSCORE and larger aortic dimensions characterised patients reclassified to moderate AS. Overall, 57% of patients had a left ventricular ejection fraction (LVEF) <50%. Clinical outcome was similar in patients with reclassified moderate or severe AS. Among patients reclassified to moderate AS, non-cardiac mortality was higher in those with LVEF <50% than in those with LVEF >= 50% (log-rankp= 0.029). Conclusions The integration of CT and transthoracic echocardiography to obtain fusion AVAi led to the reclassification of one third of patients with low-gradient AS to moderate AS. Reclassification did not affect clinical outcome, although patients reclassified to moderate AS with a LVEF <50% had worse outcomes owing to excess non-cardiac mortality. Show less
Minderhoud, S.C.S.; Velde, N. van der; Wentzel, J.J.; Geest, R.J. van der; Attrach, M.; Wielopolski, P.A.; ... ; Hirsch, A. 2020
Background Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most... Show moreBackground Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. Methods CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velocity offsets, net flow, clinically significant difference (deviation > 10% net flow), and regurgitation severity were assessed. Results Data from 175 patients (28 (17-38) years) were included, of which 84% had congenital heart disease. First, second and third order and optimized stationary tissue correction did not improve the velocity offsets and net flow measurements. Uncorrected measurements resulted in the least clinically significant differences in net flow compared to phantom corrected data. Optimized stationary tissue correction per scanner and software program resulted in net flow differences (> 10%) in 19% (MASS) and 30% (Circle cvi42) of all measurements compared to 18% (MASS) and 23% (Circle cvi42) with no correction. Compared to phantom correction, regurgitation reclassification was the least common using uncorrected data. One CMR scanner performed worse and significant net flow differences of > 10% were present both with and without stationary tissue correction in more than 30% of all measurements. Conclusion Phase offset errors had a significant impact on net flow quantification, regurgitation assessment and varied greatly between CMR scanners. Background phase correction using stationary tissue correction worsened accuracy compared to no correction on three GE Healthcare CMR scanners. Therefore, careful assessment of phase offset errors at each individual scanner is essential to determine whether routine use of phantom correction is necessary. Show less
Background: Patients with a bicuspid aortic valve (BAV) are at risk of developing valve deterioration and aortic dilatation. We aimed to investigate whether blood biomarkers are associated with... Show moreBackground: Patients with a bicuspid aortic valve (BAV) are at risk of developing valve deterioration and aortic dilatation. We aimed to investigate whether blood biomarkers are associated with disease stage inpatients with BAV.Methods: Serum levels of high sensitivity C-reactive protein (hsCRP), high sensitivity troponin T (hsTnT), N-terminal pro-B-type natriuretic peptide (NT-proBNP), and total transforming growth factor-beta 1 (TGF-beta 1) were measured in adult BAV patients with valve dysfunction or aortic pathology. Age-matched general population controls were included for TGF beta-1 measurements. Correlation analyses and multivariable linear regression were used to determine the association between (2log-transformed) biomarker levels and aortic valve regurgitation, aortic valve stenosis, aortic dilatation, or left ventricular function.Results: hsCRP and hsTnT were measured in the total group of 183 patients (median age 34 years, 25th-75th percentile 23-46), NT-proBNP in 162 patients, and TGF-beta 1 beta in 108 patients. Elevated levels of NT-proBNP were found in 20% of the BAV patients, elevated hsTnT in 6%, and elevated hsCRP in 7%. Higher hsTnT levels were independently associated with aortic regurgitation [odds ratio per doubling (OR2log) 1.34, 95% CI 1.01;1.76] and higher NT-proBNP levels with aortic valve maximal velocity (beta(2log) 0.17, 95%CI 0.07;028) and aortic regurgitation (OR2log 1.41, 95%CI 1.11;1.79). Both BAV patients with (9.9 +/- 2.7 ng/mL) and without aortic dilatation (10.4 +/- 2.9 ng/mL) showed lower TGF-beta 1 levels compared to general population controls (n = 85, 11.8 +/- 3.2 ng/mL).Conclusions: Higher NT-proBNP and hsTNT levels were associated with aortic valve disease in BAV patients. TGF-beta 1 levels were lower in BAV patients than in the general population, and not related to aortic dilatation. Longitudinal data are needed to further investigate the prognostic value of biomarkers in these patients. (C) 2020 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved. Show less
Bosch, E. van den; Cuypers, J.A.A.E.; Luijnenburg, S.E.; Duppen, N.; Boersma, E.; Budde, R.P.J.; ... ; Helbing, W.A. 2020
Aims The aim of this study was to evaluate the possible value of dobutamine stress cardiac magnetic resonance imaging (CMR) to predict adverse outcome in Tetralogy of Fallot (TOF) patients.Methods... Show moreAims The aim of this study was to evaluate the possible value of dobutamine stress cardiac magnetic resonance imaging (CMR) to predict adverse outcome in Tetralogy of Fallot (TOF) patients.Methods and results In previous prospective multicentre studies, TOF patients underwent low-dose dobutamine stress CMR (7.5 mu g/kg/min). Subsequently, during regular-care patient follow-up, patients were assessed for reaching the composite endpoint (cardiac death, arrhythmia-related hospitalization, or cardioversion/ablation, VO2 max <= 65% of predicted). A normal stress response was defined as a decrease in end-systolic volume (ESV) and increase in ejection fraction. The relative parameter change during stress was calculated as relative parameter change= [(parameter(stress) - parameterrest)/parameter(rest)] * 100. The predictive value of dobutamine stress CMR for the composite endpoint was determined using time-to-event analyses (Kaplan-Meier) and Cox proportional hazard analysis. We studied 100 patients [67 (67%) male, median age at baseline CMR 17.8 years (interquartile range 13.5-34.0), age at TOF repair 0.9 years (0.6-2.1)]. After a median follow-up of 8.6 years (6.7-14.1), 10 patients reached the composite endpoint. An abnormal stress response (30% vs. 4.4%, P = 0.021) was more frequently observed in composite endpoint patients. Also in endpoint patients, the relative decrease in right ventricular ESV decreased less during stress compared with the patients without an endpoint (-17 +/- 15 vs. -26 +/- 13 %, P= 0.045). Multivariable analyses identified an abnormal stress response (hazard ratio 10.4; 95% confidence interval 2.5-43.7; P = 0.001) as predictor for the composite endpoint.Conclusion An abnormal ventricular response to dobutamine stress is associated with adverse outcome in patients with repaired TOF. Show less
Hoven, A.T. van den; Yilmazer, S.; Chelu, R.G.; Grootel, R.W.J. van; Minderhoud, S.C.S.; Bons, L.R.; ... ; Hirsch, A. 2020
Left ventricular global longitudinal strain (LVGLS) analysis is a sensitive measurement of myocardial deformation most often done using speckle-tracking transthoracic echocardiography (TTE). We... Show moreLeft ventricular global longitudinal strain (LVGLS) analysis is a sensitive measurement of myocardial deformation most often done using speckle-tracking transthoracic echocardiography (TTE). We propose a novel approach to measure LVGLS using feature-tracking software on the magnitude dataset of 4D flow cardiovascular magnetic resonance (CMR) and compare it to dynamic computed tomography (CT) and speckle tracking TTE derived measurements. In this prospective cohort study 59 consecutive adult patients with a bicuspid aortic valve (BAV) were included. The study protocol consisted of TTE, CT, and CMR on the same day. Image analysis was done using dedicated feature-tracking (4D flow CMR and CT) and speckle-tracking (TTE) software, on apical 2-, 3-, and 4-chamber long-axis multiplanar reconstructions (4D flow CMR and CT) or standard apical 2-, 3-, and 4-chamber acquisitions (TTE). CMR and CT GLS analysis was feasible in all patients. Good correlations were observed for GLS measured by CMR (- 21 +/- 3%) and CT (- 20 +/- 3%) versus TTE (- 20 +/- 3%, Pearson's r: 0.67 and 0.65, p < 0.001). CMR also correlated well with CT (Pearson's r 0.62, p < 0.001). The inter-observer analysis showed moderate to good reproducibility of GLS measurement by CMR, CT and TTE (Pearsons's r: 0.51, 0.77, 0.70 respectively; p < 0.05). Additionally, ejection fraction (EF), end-diastolic and end-systolic volume measurements (EDV and ESV) correlated well between all modalities (Pearson's r > 0.61, p < 0.001). Feature-tracking GLS analysis is feasible using the magnitude images acquired with 4D flow CMR. GLS measurement by CMR correlates well with CT and speckle-tracking 2D TTE. GLS analysis on 4D flow CMR allows for an integrative approach, integrating flow and functional data in a single sequence. Not applicable, observational study. Show less
BackgroundPreeclampsia is a female-specific risk factor for the development of future cardiovascular disease. Whether early preventive cardiovascular disease risk screenings combined with risk... Show moreBackgroundPreeclampsia is a female-specific risk factor for the development of future cardiovascular disease. Whether early preventive cardiovascular disease risk screenings combined with risk-based lifestyle interventions in women with previous preeclampsia are beneficial and cost-effective is unknown.MethodsA micro-simulation model was developed to assess the life-long impact of preventive cardiovascular screening strategies initiated after women experienced preeclampsia during pregnancy. Screening was started at the age of 30 or 40 years and repeated every five years. Data (initial and follow-up) from women with a history of preeclampsia was used to calculate 10-year cardiovascular disease risk estimates according to Framingham Risk Score. An absolute risk threshold of 2% was evaluated for treatment selection, i.e. lifestyle interventions (e.g. increasing physical activity). Screening benefits were assessed in terms of costs and quality-adjusted-life-years, and incremental cost-effectiveness ratios compared with no screening.ResultsExpected health outcomes for no screening are 27.35 quality-adjusted-life-years and increase to 27.43 quality-adjusted-life-years (screening at 30 years with 2% threshold). The expected costs for no screening are euro9426 and around euro13,881 for screening at 30 years (for a 2% threshold). Preventive screening at 40 years with a 2% threshold has the most favourable incremental cost-effectiveness ratio, i.e. euro34,996/quality-adjusted-life-year, compared with other screening scenarios and no screening.ConclusionsEarly cardiovascular disease risk screening followed by risk-based lifestyle interventions may lead to small long-term health benefits in women with a history of preeclampsia. However, the cost-effectiveness of a lifelong cardiovascular prevention programme starting early after preeclampsia with risk-based lifestyle advice alone is relatively unfavourable. A combination of risk-based lifestyle advice plus medical therapy may be more beneficial. Show less
Objective Little is known about the prevalence and degree of deformation of surgically implanted aortic biological valve prostheses (bio-sAVRs). We assessed bio-sAVR deformation using multidetector... Show moreObjective Little is known about the prevalence and degree of deformation of surgically implanted aortic biological valve prostheses (bio-sAVRs). We assessed bio-sAVR deformation using multidetector-row computed tomography (MDCT). Methods Three imaging databases were searched for patients with MDCT performed after bio-sAVR implantation. Minimal and maximal valve ring diameters were obtained in systole and/or diastole, depending on the acquired cardiac phase(s). The eccentricity index (EI) was calculated as a measure of deformation as (1 - (minimal diameter/maximal diameter)) x 100%. EI of < 5% was considered none or trivial deformation, 5-10% mild deformation, and > 10% non-circular. Indications for MDCT and implanted valve type were retrieved. Results One hundred fifty-two scans of bio-sAVRs were included. One hundred seventeen measurements were performed in systole and 35 in diastole. None or trivial deformation (EI < 5%) was seen in 67/152 (44%) of patients. Mild deformation (EI 5-10%) was seen in 59/152 (39%) and non-circularity was found in 26/152 (17%) of cases. Overall, median EI was 5.5% (IQR 3.4-7.8). In 77 patients, both systolic and diastolic measurements were performed from the same scan. For these scans, the median EI was 6.5% (IQR 3.4-10.2) in systole and 5.1% (IQR3.1-7.6) in diastole, with a significant difference between both groups (p = 0.006). Conclusions Surgically implanted aortic biological valve prostheses show mild deformation in 39% of cases and were considered non-circular in 17% of studied valves. Show less
ObjectiveWomen with premature ovarian insufficiency (POI) enter menopause before age 40. Early menopause was associated with increased risk for coronary artery disease (CAD), death from... Show moreObjectiveWomen with premature ovarian insufficiency (POI) enter menopause before age 40. Early menopause was associated with increased risk for coronary artery disease (CAD), death from cardiovascular disease and all-cause mortality. We compared the prevalence of CAD between middle-aged women on average 10years following the initial POI diagnosis, with a population-based cohort.DesignCross-sectional case-control study.ParticipantsWomen from two Dutch University Medical Centers above 45years of age previously diagnosed with POI (n=98) were selected and compared with age- and race-matched controls from the Multi-Ethnic Study of Atherosclerosis (MESA).MeasurementsThe primary outcome was detectable coronary artery calcium (CAC) determined by coronary computed tomography (CCT).ResultsWomen with POI had significantly higher blood pressure, cholesterol and glucose, despite lower BMI compared to controls. Similar proportions of detectable CAC (CAC score >0 Agatston Units) were observed in women with POI and controls (POI n=16 (16%), controls n=52 (18%), P=0.40 and P-adj=0.93). In women with POI separately, we were not able to identify associations between CVD risk factors and CAC. The following CVD risk factors in controls were positively associated with CAC: age, diabetes mellitus, hypertension and LDL cholesterol. HRT use was negatively associated with CAC in controls.ConclusionsThe presence of CAC did not differ significantly in women with POI around 50years of age, compared to an age- and race-matched control group. We observe no increased calcified coronary disease in POI patients, despite the presence of unfavourable cardiovascular risk factors in these women. Show less
Objective Variations in coronary anatomy, like absent left main stem and left dominant coronary system, have been described in patients with Turner syndrome (TS) and in patients with bicuspid... Show moreObjective Variations in coronary anatomy, like absent left main stem and left dominant coronary system, have been described in patients with Turner syndrome (TS) and in patients with bicuspid aortic valves (BAV). It is unknown whether coronary variations in TS are related to BAV and to specific BAV subtypes.Aim To compare coronary anatomy in patients with TS with/without BAV versus isolated BAV and to study BAV morphology subtypes in these groups.Methods Coronary anatomy and BAV morphology were studied in 86 patients with TS (20 TS-BAV, 66 TS-tricuspid aortic valve) and 86 patients with isolated BAV (37 +/- 13 years vs 42 +/- 15 years, respectively) by CT.Results T here was no significant difference in coronary dominance between patients with TS with and without BAV (25% vs 21%, p=0.933). BAVs with fusion of right and left coronary leaflets (RL BAV) without raphe showed a high prevalence of left coronary dominance in both TS-BAV and isolated BAV (both 38%). Absent left main stem was more often seen in TS-BAV as compared with isolated BAV (10% vs 0%). All patients with TS-BAV with absent left main stem had RL BAV without raphe.Conclusion T he equal distribution of left dominance in RL BAV without raphe in TS-BAV and isolated BAV suggests that presence of left dominance is a feature of BAVs without raphe, independent of TS. Both TS and RL BAV without raphe seem independently associated with absent left main stems. Awareness of the higher incidence of particularly absent left main stems is important to avoid complications during hypothermic perfusion. Show less
A dedicated software package that could semi-automatically assess differences in aortic maximal cross-sectional diameters from consecutive CT scans would most likely reduce the post-processing time... Show moreA dedicated software package that could semi-automatically assess differences in aortic maximal cross-sectional diameters from consecutive CT scans would most likely reduce the post-processing time and effort by the physicians. The aim of this study was to present and assess the quality of a new tool for the semi-automatic quantification of thoracic aorta dilation dimensions. Twenty-nine patients with two CTA scans of the thoracic aorta for which the official clinical report indicated an increase in aortic diameters were included in the study. Aortic maximal cross-sectional diameters of baseline and follow-up studies generated semi-automatically by the software were compared with corresponding manual measurements. The semi-automatic measurements were performed at seven landmarks defined on the baseline scan by two operators. Bias, Bland-Altman plots and intraclass correlation coefficients were calculated between the two methods and, for the semi-automatic software, also between two observers. The average time difference between the two scans of a single patient was 1188 +/- 622 days. For the semi-automatic software, in 2 out of 29 patients, manual interaction was necessary; in the remaining 27 patients (93.1%), semi-automatic results were generated, demonstrating excellent intraclass correlation coefficients (all values0.91) and small differences, especially for the proximal aortic arch (baseline: 0.19 +/- 1.30mm; follow-up: 0.44 +/- 2.21mm), the mid descending aorta (0.37 +/- 1.64mm; 0.37 +/- 2.06mm), and the diaphragm (0.30 +/- 1.14mm; 0.37 +/- 1.80mm). The inter-observer variability was low with all errors in diameters1mm, and intraclass correlation coefficients all 0.95. The semi-automatic tool decreased the processing time by 40% (13 vs. 22min). In this work, a semi-automatic software package that allows the assessment of thoracic aorta diameters from baseline and follow-up CTs (and their differences), was presented, and demonstrated high accuracy and low inter-observer variability. Show less
Objectives Compare the predictive performance of Framingham Risk Score (FRS), Pooled Cohort Equations (PCEs) and Systematic COronary Risk Evaluation (SCORE) model between women with and without a... Show moreObjectives Compare the predictive performance of Framingham Risk Score (FRS), Pooled Cohort Equations (PCEs) and Systematic COronary Risk Evaluation (SCORE) model between women with and without a history of hypertensive disorders of pregnancy (hHDP) and determine the effects of recalibration and refitting on predictive performance. Methods We included 29 751 women, 6302 with hHDP and 17 369 without. We assessed whether models accurately predicted observed 10-year cardiovascular disease (CVD) risk (calibration) and whether they accurately distinguished between women developing CVD during follow-up and not (discrimination), separately for women with and without hHDP. We also recalibrated (updating intercept and slope) and refitted (recalculating coefficients) the models. Results Original FRS and PCEs overpredicted 10-year CVD risks, with expected:observed (E:O) ratios ranging from 1.51 (for FRS in women with hHDP) to 2.29 (for PCEs in women without hHDP), while E:O ratios were close to 1 for SCORE. Overprediction attenuated slightly after recalibration for FRS and PCEs in both hHDP groups. Discrimination was reasonable for all models, with C-statistics ranging from 0.70-0.81 (women with hHDP) and 0.72-0.74 (women without hHDP). C-statistics improved slightly after refitting 0.71-0.83 (with hHDP) and 0.73-0.80 (without hHDP). The E:O ratio of the original PCE model was statistically significantly better in women with hHDP compared with women without hHDP. Conclusions SCORE performed best in terms of both calibration and discrimination, while FRS and PCEs overpredicted risk in women with and without hHDP, but improved after recalibrating and refitting the models. No separate model for women with hHDP seems necessary, despite their higher baseline risk. Show less
Background: No established reference-standard technique is available for ascending aortic diameter measurements. The aim of this study was to determine agreement between modalities and techniques... Show moreBackground: No established reference-standard technique is available for ascending aortic diameter measurements. The aim of this study was to determine agreement between modalities and techniques.Methods: In patients with aortic pathology transthoracic echocardiography, computed tomography angiography (CTA) and magnetic resonance angiography (MRA) were performed. Aortic diameters were measured at the sinus of Valsalva (SoV), sinotubular junction (STJ) and tubular ascending aorta (TAA) during mid-systole and end-diastole. In echocardiography both the inner edge-to-inner edge (14 edge) and leading edge-to-leading edge (L-L edge) methods were applied, and the length of the aortic annulus to the most cranial visible part of the ascending aorta was measured. In CTA and MRA the I-1 method was used.Results: Fifty patients with bicuspid aortic valve (36 +/- 13 years, 26' female) and 50 Turner patients (35 +/- 13 years) were included. Comparison of all aortic measurements showed a mean difference of 5.4 +/- 2.7 mm for the SoV, 5.1 +/- 2.0 mm for the STJ and 4.8 +/- 2.1 mm for the TAA. The maximum difference was 18 mm. The best agreement was found between echocardiography L-L edge and CTA during mid-systole. CTA and MRA showed good agreement. A mean difference of 1.5 +/- 1.3 mm and 1.8 +/- 1.5 mm was demonstrated at the level of the STJ and TAA comparing mid-systolic with end-diastolic diameters. The visible length of the aorta increased on average 5.3 +/- 5.1 mmW during mid-systole.Conclusions: MRA and CTA showed best agreement with L-L edge method by echocardiography. In individual patients large differences in ascending aortic diameter were demonstrated, warranting measurement standardization. The use of CIA or MRA is advised at least once. (C) 2018 Elsevier B.V. All rights reserved. Show less
AimTo provide a comprehensive overview of cardiovascular disease (CVD) risk prediction models for women and models that include female-specific predictors.MethodsWe performed a systematic review of... Show moreAimTo provide a comprehensive overview of cardiovascular disease (CVD) risk prediction models for women and models that include female-specific predictors.MethodsWe performed a systematic review of CVD risk prediction models for women in the general population by updating a previous review. We searched Medline and Embase up to July 2017 and included studies in which; (a) a new model was developed, (b) an existing model was validated, or (c) a predictor was added to an existing model.ResultsA total of 285 prediction models for women have been developed, of these 160 (56%) were female-specific models, in which a separate model was developed solely in women and 125 (44%) were sex-predictor models. Out of the 160 female-specific models, 2 (1.3%) included one or more female-specific predictors (mostly reproductive risk factors). A total of 591 validations of sex-predictor or female-specific models were identified in 206 papers. Of these, 333 (56%) validations concerned nine models (five versions of Framingham, SCORE, Pooled Cohort Equations and QRISK). The median and pooled C statistics were comparable for sex-predictor and female-specific models. In 260 articles the added value of new predictors to an existing model was described, however in only 3 of these female-specific that no competing interests exist. predictors (reproductive risk factors) were added.ConclusionsThere is an abundance of models for women in the general population. Female-specific and sex-predictor models have similar predictors and performance. Female-specific predictors are rarely included. Further research is needed to assess the added value of female-specific predictors to CVD models for women and provide physicians with a well-performing prediction model for women. Show less