PurposeMetastasectomy is a common treatment option for patients with colorectal lung metastases (CLM). Challenges exist with margin assessment and identification of small nodules, especially during... Show morePurposeMetastasectomy is a common treatment option for patients with colorectal lung metastases (CLM). Challenges exist with margin assessment and identification of small nodules, especially during minimally invasive surgery. Intraoperative fluorescence imaging has the potential to overcome these challenges. The aim of this study was to assess feasibility of targeting CLM with the carcinoembryonic antigen (CEA) specific fluorescent tracer SGM-101.MethodsThis was a prospective, open-label feasibility study. The primary outcome was the number of CLM that showed a true positive fluorescence signal with SGM-101. Fluorescence positive signal was defined as a signal-to-background ratio (SBR) ≥ 1.5. A secondary endpoint was the CEA expression in the colorectal lung metastases, assessed with the immunohistochemistry, and scored by the total immunostaining score.ResultsThirteen patients were included in this study. Positive fluorescence signal with in vivo, back table, and closed-field bread loaf imaging was observed in 31%, 45%, and 94% of the tumors respectively. Median SBRs for the three imaging modalities were 1.00 (IQR: 1.00–1.53), 1.45 (IQR: 1.00–1.89), and 4.81 (IQR: 2.70–7.41). All tumor lesions had a maximum total immunostaining score for CEA expression of 12/12.ConclusionThis study demonstrated the potential of fluorescence imaging of CLM with SGM-101. CEA expression was observed in all tumors, and closed-field imaging showed excellent CEA specific targeting of the tracer to the tumor nodules. The full potential of SGM-101 for in vivo detection of the tracer can be achieved with improved minimal invasive imaging systems and optimal patient selection. Show less
Objective:To determine the nationwide implementation and surgical outcome of minor and major robotic liver surgery (RLS) and assess the first phase of implementation of RLS during the learning... Show moreObjective:To determine the nationwide implementation and surgical outcome of minor and major robotic liver surgery (RLS) and assess the first phase of implementation of RLS during the learning curve. Background:RLS may be a valuable alternative to laparoscopic liver surgery. Nationwide population-based studies with data on implementation and outcome of RLS are lacking. Methods:Multicenter retrospective cohort study including consecutive patients who underwent RLS for all indications in 9 Dutch centers (August 2014-March 2021). Data on all liver resections were obtained from the mandatory nationwide Dutch Hepato Biliary Audit (DHBA) including data from all 27 centers for liver surgery in the Netherlands. Outcomes were stratified for minor, technically major, and anatomically major RLS. Learning curve effect was assessed using cumulative sum analysis for blood loss. Results:Of 9437 liver resections, 400 were RLS (4.2%) procedures including 207 minor (52.2%), 141 technically major (35.3%), and 52 anatomically major (13%). The nationwide use of RLS increased from 0.2% in 2014 to 11.9% in 2020. The proportion of RLS among all minimally invasive liver resections increased from 2% to 28%. Median blood loss was 150 mL (interquartile range 50-350 mL] and the conversion rate 6.3% (n=25). The rate of Clavien-Dindo grade >= III complications was 7.0% (n=27), median length of hospital stay 4 days (interquartile range 2-5) and 30-day/in-hospital mortality 0.8% (n=3). The R0 resection rate was 83.2% (n=263). Cumulative sum analysis for blood loss found a learning curve of at least 33 major RLS procedures. Conclusions:The nationwide use of RLS in the Netherlands has increased rapidly with currently one-tenth of all liver resections and one-fourth of all minimally invasive liver resections being performed robotically. Although surgical outcomes of RLS in selected patient seem favorable, future prospective studies should determine its added value. Show less
Purpose: To assess the quantitative minimal ablation margin (MAM) in patients with colorectal liver metastases (CRLM) treated with percutaneous thermal ablation (TA) and correlate the quantitative... Show morePurpose: To assess the quantitative minimal ablation margin (MAM) in patients with colorectal liver metastases (CRLM) treated with percutaneous thermal ablation (TA) and correlate the quantitative MAM with local tumour recurrence (LTR).Method: Thirty-nine of 143 patients with solitary or multiple CRLM who underwent a first percutaneous TA procedure between January 2011 and May 2020 were considered eligible for study enrolment. Image fusion of pre-and post-ablation scans and 3D quantitative MAM assessment was performed using the in-house developed semi-automatic rigid MRI/CECT-CECT co-registration software deLIVERed. The quantitative MAM was analysed and correlated with LTR.Results: Eighteen (46 %) patients were additionally excluded from further analyses due to suboptimal co -registration (quality co-registration score < 3). The quality of co-registration was considered sufficient in 21 (54 %) patients with a total of 29 CRLM. LTR was found in 5 of 29 (17 %) TA-treated CRLM. In total, 12 (41 %) negative MAMs were measured (mean MAM-4.7 +/- 2.7 mm). Negative MAMs were significantly more frequently seen in patients who developed LTR (100 %) compared to those without LTR (29 %; p = 0.003). The median MAM of patients who developed LTR (-6.6 mm (IQR-9.5 to-4.6)) was significantly smaller compared to the median MAM of patients without LTR (0.5 mm (IQR-1.8 to 3.0); p < 0.001). The ROC curve showed high accuracy in predicting LTR for the quantitative MAM (area under the curve of 0.975 +/- 0.029).Conclusion: This study demonstrated the feasibility of 3D quantitative MAM assessment, using deLIVERed co -registration software, to assess technical success of TA in patients with CRLM and to predict LTR. Show less
The majority of breast cancer patients is treated with breast-conserving surgery (BCS) combined with adjuvant radiation therapy. Up to 40% of patients has a tumor-positive resection margin after... Show moreThe majority of breast cancer patients is treated with breast-conserving surgery (BCS) combined with adjuvant radiation therapy. Up to 40% of patients has a tumor-positive resection margin after BCS, which necessitates re-resection or additional boost radiation. Cathepsin-targeted near-infrared fluorescence imaging during BCS could be used to detect residual cancer in the surgical cavity and guide additional resection, thereby preventing tumor-positive resection margins and associated mutilating treatments. The cysteine cathepsins are a family of proteases that play a major role in normal cellular physiology and neoplastic transformation. In breast cancer, the increased enzymatic activity and aberrant localization of many of the cysteine cathepsins drive tumor progression, proliferation, invasion, and metastasis. The upregulation of cysteine cathepsins in breast cancer cells indicates their potential as a target for intraoperative fluorescence imaging. This review provides a summary of the current knowledge on the role and expression of the most important cysteine cathepsins in breast cancer to better understand their potential as a target for fluorescence-guided surgery (FGS). In addition, it gives an overview of the cathepsin-targeted fluorescent probes that have been investigated preclinically and in breast cancer patients. The current review underscores that cysteine cathepsins are highly suitable molecular targets for FGS because of favorable expression and activity patterns in virtually all breast cancer subtypes. This is confirmed by cathepsin-targeted fluorescent probes that have been shown to facilitate in vivo breast cancer visualization and tumor resection in mouse models and breast cancer patients. These findings indicate that cathepsin-targeted FGS has potential to improve treatment outcomes in breast cancer patients. Show less
The majority of breast cancer patients is treated with breast-conserving surgery (BCS) combined with adjuvant radiation therapy. Up to 40% of patients has a tumor-positive resection margin after... Show moreThe majority of breast cancer patients is treated with breast-conserving surgery (BCS) combined with adjuvant radiation therapy. Up to 40% of patients has a tumor-positive resection margin after BCS, which necessitates re-resection or additional boost radiation. Cathepsin-targeted near-infrared fluorescence imaging during BCS could be used to detect residual cancer in the surgical cavity and guide additional resection, thereby preventing tumor-positive resection margins and associated mutilating treatments. The cysteine cathepsins are a family of proteases that play a major role in normal cellular physiology and neoplastic transformation. In breast cancer, the increased enzymatic activity and aberrant localization of many of the cysteine cathepsins drive tumor progression, proliferation, invasion, and metastasis. The upregulation of cysteine cathepsins in breast cancer cells indicates their potential as a target for intraoperative fluorescence imaging. This review provides a summary of the current knowledge on the role and expression of the most important cysteine cathepsins in breast cancer to better understand their potential as a target for fluorescence-guided surgery (FGS). In addition, it gives an overview of the cathepsin-targeted fluorescent probes that have been investigated preclinically and in breast cancer patients. The current review underscores that cysteine cathepsins are highly suitable molecular targets for FGS because of favorable expression and activity patterns in virtually all breast cancer subtypes. This is confirmed by cathepsin-targeted fluorescent probes that have been shown to facilitate in vivo breast cancer visualization and tumor resection in mouse models and breast cancer patients. These findings indicate that cathepsin-targeted FGS has potential to improve treatment outcomes in breast cancer patients. Show less
Simple Summary: We have developed a formulation for an innovative, quenched, cathepsin-targeted, fluorescent molecular probe to enhance resection quality for several solid-tumor cancers. Unlike... Show moreSimple Summary: We have developed a formulation for an innovative, quenched, cathepsin-targeted, fluorescent molecular probe to enhance resection quality for several solid-tumor cancers. Unlike other formulations for imaging probes or tracers in development and entering the clinic, which require systemic administration hours before the procedure, this current formulation is applied topically into the surgical cavity immediately after a standard of care resection. Within minutes of application, the probe activates in the presence of residual cancer in the surgical wound and provides a strong fluorescent signal that precisely delineates any remaining cancer, enabling a more complete resection. Utilization of this imaging gel formulation for topical application to detect breast cancer in the surgical cavity during surgery has the potential to reduce re-excisions, with consequent savings in healthcare costs and enhancement in patient quality of life. Background: Tumor-positive surgical margins during primary breast cancer (BCa) surgery are associated with a two-fold increase in the risk of local recurrence when compared with tumor-negative margins. Pathological microscopic evaluation of the samples only assesses about 1/10 of 1% of the entire volume of the removed BCa specimens, leading to margin under-sampling and potential local recurrence in patients with pathologically clean margins, i.e., false negative margins. In the case of tumor-positive margins, patients need to undergo re-excision and/or radiation therapy, resulting in increases in complications, morbidity, and healthcare costs. Development of a simple real-time imaging technique to identify residual BCa in the surgical cavity rapidly and precisely could significantly improve the quality of care. Methods: A small-molecule, fluorescently quenched protease-substrate probe, AKRO-QC-ICG, was tested as part of a thermosensitive imaging gel formulated for topical application and imaging of the BCa surgical cavity. Results: More than forty formulations of gel mixtures were investigated to enable easy fluid application and subsequent solidification once applied, preventing dripping and pooling in the surgical cavity. The final formulation was tested using human BCa orthotopic implants in nude and NSG patient-derived xenografts (PDX) mice. This formulation of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel was found to be a good solvent for the probe, with a desirable thermo-reversible solid-gel transition and mechanical strength for distribution of AKRO-QC-ICG on the surfaces of tissue. It demonstrated excellent ability to detect BCa tissue after 10 min exposure, with a high signal-to-noise ratio both in mouse xenografts and freshly excised human lumpectomy tissue. The in vivo efficacy of the AKRO-QC-ICG imaging gel to detect BCa revealed the levels of sensitivity/specificity = 0.92/1 in 12 nude mice, which was corroborated with the sensitivity/specificity = 0.94/1 in 10 PDX mice. Conclusions: Utilization of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel for topical application to detect BCa in the surgical cavity during surgery has the potential to reduce re-excisions, with consequent savings in healthcare costs and enhancement in patient quality of life. Show less
Background: Robotic liver surgery represents the most recent evolution in the field of minimally-invasive liver surgery. For planning and guidance of liver resections, surgeons currently rely on... Show moreBackground: Robotic liver surgery represents the most recent evolution in the field of minimally-invasive liver surgery. For planning and guidance of liver resections, surgeons currently rely on preoperative 2-dimensional (2D) CT and/or MR imaging and intraoperative ultrasonography. Translating 2D images into digital 3-dimensional (3D) models may improve both preoperative planning and surgical guidance. The da Vinci (R) robotic surgical system is a platform suitable for the integration of multiple imaging modalities into one single view. In this study, we describe multimodal imaging options and introduce the Robotic Liver Surgery Cockpit; Methods: in-house developed software was used and validated for segmentation and registration to create a virtual reality 3D model of the liver based on preoperative imaging. The accuracy of the 3D models in the clinical setting was objectively assessed in 15 patients by measuring tumor diameters and subjectively with a postoperative conducted questionnaire; Results: Implementation and applicability of the 3D model in the surgical cockpit was feasible in all patients and the quality of the 3D reconstructions was high in 14 (93%) of cases. Tumor diameters measured on CT and/or MR imaging were comparable to automated measurements using the segmentation software and 3D models; Conclusions: the 3D model was successfully incorporated in the robotic surgery console as part of a multimodality imaging platform and aided the surgeon in planning and guidance of the resection. Future studies should focus on further automation of 3D rendering and progress into augmented reality. Show less
Introduction: Anastomotic leakage (AL) is one of the major complications after colorectal surgery. Compromised tissue perfusion at the anastomosis site increases the risk of AL. Several cohort... Show moreIntroduction: Anastomotic leakage (AL) is one of the major complications after colorectal surgery. Compromised tissue perfusion at the anastomosis site increases the risk of AL. Several cohort studies have shown that indocyanine green (ICG) combined with fluorescent nearinfrared imaging is a feasible and reproducible technique for real-time intraoperative imaging of tissue perfusion, leading to reduced leakage rates after colorectal resection. Unfortunately, these studies were not randomised. Therefore, we propose a randomised controlled trial to assess the value of ICG-guided surgery in reducing AL after colorectal surgery. Methods and analysis: A multicentre, randomised controlled clinical trial will be conducted to assess the benefit of ICG-guided surgery in preventing AL. A total of 978 patients scheduled for colorectal surgery will be included. Patients will be randomised between the Fluorescence Guided Bowel Anastomosis group and the Conventional Bowel Anastomosis group. The primary endpoint is clinically relevant AL (defined as requiring active therapeutic intervention or reoperation) within 90 days after surgery. Among the secondary endpoints are 30-day clinically relevant AL, all-cause postoperative complications, all-cause and AL-related mortality, surgical and non-surgical reinterventions, total surgical time, length of hospital stay and all-cause and AL-related readmittance. Ethics and dissemination: This protocol has been approved by the Medical Ethical Committee Leiden-Den Haag-Delft (METC-LDD) and is registered at ClinicalTrials. gov and trialregister.nl . The results of this study will be reported through peer-reviewed publications and conference presentations. Show less
Bijlstra, O.D.; Boreel, M.M.E.; Mossel, S. van; Burgmans, M.C.; Kapiteijn, E.H.W.; Oprea-Lager, D.E.; ... ; Geus-Oei, L.F. de 2022
(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal... Show more(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal ablation are the most common local treatment options of choice. Despite development and improvement in local treatment options, (local) recurrence remains a significant clinical problem. Many different imaging modalities can be used in the follow-up after treatment of CRLM, lacking evidence-based international consensus on the modality of choice. In this systematic review, we evaluated 18F-FDG-PET-CT performance after surgical resection, thermal ablation, radioembolization, and neoadjuvant and palliative chemotherapy based on current published literature. (2) Methods: A systematic literature search was performed on the PubMed database. (3) Results: A total of 31 original articles were included in the analysis. Only one suitable study was found describing the role of 18F-FDG-PET-CT after surgery, which makes it hard to draw a firm conclusion. 18F-FDG-PET-CT showed to be of additional value in the follow-up after thermal ablation, palliative chemotherapy, and radioembolization. 18F-FDG-PET-CT was found to be a poor to moderate predictor of pathologic response after neoadjuvant chemotherapy. (4) Conclusions: 18F-FDG-PET-CT is superior to conventional morphological imaging modalities in the early detection of residual disease after thermal ablation and in the treatment evaluation and prediction of prognosis during palliative chemotherapy and after radioembolization, and 18F-FDG-PET-CT could be considered in selected cases after neoadjuvant chemotherapy and surgical resection. Show less
Kalisvaart, G.M.; Meijer, R.P.J.; Bijlstra, O.D.; Galema, H.A.; Steur, W.O. de; Hartgrink, H.H.; ... ; Hage, J.A. van der 2022
Simple Summary: Surgical resection plays a pivotal role in the treatment of GIST patients. The current study aims to explore the use of near-infrared fluorescence imaging to optimize the... Show moreSimple Summary: Surgical resection plays a pivotal role in the treatment of GIST patients. The current study aims to explore the use of near-infrared fluorescence imaging to optimize the intraoperative tumor identification of GISTs. For this purpose, the potential and limitations of the widely used, and non-specific, tracer indocyanine green were assessed in a multicenter study including 10 patients. Our results show that GISTs typically have similar fluorescence intensity to the surrounding tissue, within several minutes after the intravenous administration of indocyanine green. These findings justify future research into specific fluorescent tracers for GISTs, and set a reference for future intraoperative imaging trials. Background: Optimal intraoperative tumor identification of gastrointestinal stromal tumors (GISTs) is important for the quality of surgical resections. This study aims to assess the potential of near-infrared fluorescence (NIRF) imaging with indocyanine green (ICG) to improve intraoperative tumor identification. Methods: Ten GIST patients, planned to undergo resection, were included. During surgery, 10 mg of ICG was intravenously administered, and NIRF imaging was performed at 5, 10, and 15 min after the injection. The tumor fluorescence intensity was visually assessed, and tumor-to-background ratios (TBRs) were calculated for exophytic lesions. Results: Eleven GIST lesions were imaged. The fluorescence intensity of the tumor was visually synchronous and similar to the background in five lesions. In one lesion, the tumor fluorescence was more intense than in the surrounding tissue. Almost no fluorescence was observed in both the tumor and healthy peritoneal tissue in two patients with GIST lesions adjacent to the liver. In three GISTs without exophytic growth, no fluorescence of the tumor was observed. The median TBRs at 5, 10, and 15 min were 1.0 (0.4-1.2), 1.0 (0.5-1.9), and 0.9 (0.7-1.2), respectively. Conclusion: GISTs typically show similar fluorescence intensity to the surrounding tissue in NIRF imaging after intraoperative ICG administration. Therefore, intraoperatively administered ICG is currently not applicable for adequate tumor identification, and further research should focus on the development of tumor-specific fluorescent tracers for GISTs. Show less
Lung cancer is the most common cancer type worldwide, with non-small cell lung cancer (NSCLC) being the most common subtype. Non-disseminated NSCLC is mainly treated with surgical resection. The... Show moreLung cancer is the most common cancer type worldwide, with non-small cell lung cancer (NSCLC) being the most common subtype. Non-disseminated NSCLC is mainly treated with surgical resection. The intraoperative detection of lung cancer can be challenging, since small and deeply located pulmonary nodules can be invisible under white light. Due to the increasing use of minimally invasive surgical techniques, tactile information is often reduced. Therefore, several intraoperative imaging techniques have been tested to localize pulmonary nodules, of which near-infrared (NIR) fluorescence is an emerging modality. In this systematic review, the available literature on fluorescence imaging of lung cancers is presented, which shows that NIR fluorescence-guided lung surgery has the potential to identify the tumor during surgery, detect additional lesions and prevent tumor-positive resection margins. Show less
Bijlstra, O.D.; Boreel, M.M.E.; Mossel, S. van; Burgmans, M.C.; Kapiteijn, E.H.W.; Oprea-Lager, D.E.; ... ; Geus-Oei, L.F. de 2022
(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal... Show more(1) Background: Up to 50% of patients with colorectal cancer either have synchronous colorectal liver metastases (CRLM) or develop CRLM over the course of their disease. Surgery and thermal ablation are the most common local treatment options of choice. Despite development and improvement in local treatment options, (local) recurrence remains a significant clinical problem. Many different imaging modalities can be used in the follow-up after treatment of CRLM, lacking evidence-based international consensus on the modality of choice. In this systematic review, we evaluated F-18-FDG-PET-CT performance after surgical resection, thermal ablation, radioembolization, and neoadjuvant and palliative chemotherapy based on current published literature. (2) Methods: A systematic literature search was performed on the PubMed database. (3) Results: A total of 31 original articles were included in the analysis. Only one suitable study was found describing the role of F-18-FDG-PET-CT after surgery, which makes it hard to draw a firm conclusion. F-18-FDG-PET-CT showed to be of additional value in the follow-up after thermal ablation, palliative chemotherapy, and radioembolization. F-18-FDG-PET-CT was found to be a poor to moderate predictor of pathologic response after neoadjuvant chemotherapy. (4) Conclusions: F-18-FDG-PET-CT is superior to conventional morphological imaging modalities in the early detection of residual disease after thermal ablation and in the treatment evaluation and prediction of prognosis during palliative chemotherapy and after radioembolization, and F-18-FDG-PET-CT could be considered in selected cases after neoadjuvant chemotherapy and surgical resection. Show less
INTRODUCTION AND IMPORTANCE: Gastrointestinal stromal tumors are the most prevalent mesenchymal tumors of the gastrointestinal tract. Distant metastases are most often found in the liver or... Show moreINTRODUCTION AND IMPORTANCE: Gastrointestinal stromal tumors are the most prevalent mesenchymal tumors of the gastrointestinal tract. Distant metastases are most often found in the liver or peritoneum with surgery being the preferred treatment option. In our center, fluorescence-guided surgery with indocyanine green is used as standard-of-care for hepatic metastases in colorectal cancer. This case report describes fluorescence-guided metastasectomy for a hepatic gastrointestinal stromal tumor in two patients undergoing open liver resection and radiofrequency ablation.CASE PRESENTATION: A 69-year old women was seen during follow-up after laparoscopic resection of a GIST in the lesser curvature of the stomach. Contrast-enhanced computed tomography imaging showed two suspicious lesions in liver segment VI and VIII. Intraoperative near-infrared fluorescence imaging of the liver clearly revealed the lesion in segment VIII, and an additional lesion in segment V - which was not seen on preoperative CT-imaging, neither on intraoperative ultrasonography. The lesion in segment VI was not seen with NIRF imaging due to its deeper location in the liver parenchyma. The second case is an 82-year old man who was also diagnosed with liver metastases from a GIST in the stomach and was scheduled for near-infrared fluorescence-guided liver resection and radio frequency ablation.CLINICAL DISCUSSION: In this case report we demonstrated the feasibility of fluorescence-guided surgery in detection of liver metastases and treatment planning of two patients with hepatic GIST metastases using indocyanine green.CONCLUSION: NIRF-imaging with ICG is useful for identification of preoperatively discovered lesions, surgical resection planning and margin evaluation, and for detection of additional hepatic GIST metastases. (C) 2020 The Authors. Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. This is an open access article under the CC BY-NC-ND license (http://creative commons.org/licenses/by-nc-nd/4.0/). Show less
Purpose: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the... Show morePurpose: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery.Experimental Design: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer.Results: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio.Conclusions: cRGD- ZW800- 1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature. Show less