Aims To analyse and optimize the interobserver agreement for gross target volume (GTV) delineation on cardiac computed tomography (CCT) based on electroanatomical mapping (EAM) data acquired to... Show moreAims To analyse and optimize the interobserver agreement for gross target volume (GTV) delineation on cardiac computed tomography (CCT) based on electroanatomical mapping (EAM) data acquired to guide radiotherapy for ventricular tachycardia (VT).Methods and results Electroanatomical mapping data were exported and merged with the segmented CCT using manual registration by two observers. A GTV was created by both observers for predefined left ventricular (LV) areas based on preselected endocardial EAM points indicating a two-dimensional (2D) surface area of interest. The influence of (interobserver) registration accuracy and availability of EAM data on the final GTV and 2D surface location within each LV area was evaluated. The median distance between the CCT and EAM after registration was 2.7 mm, 95th percentile 6.2 mm for observer #1 and 3.0 mm, 95th percentile 7.6 mm for observer #2 (P = 0.9). Created GTVs were significantly different (8 vs. 19 mL) with lowest GTV overlap (35%) for lateral wall target areas. Similarly, the highest shift between 2D surfaces was observed for the septal LV (6.4 mm). The optimal surface registration accuracy (2.6 mm) and interobserver agreement (A interobserver EAM surface registration 1.3 mm) was achieved if at least three cardiac chambers were mapped, including high-quality endocardial LV EAM.Conclusion Detailed EAM of at least three chambers allows for accurate co-registration of EAM data with CCT and high interobserver agreement to guide radiotherapy of VT. However, the substrate location should be taken in consideration when creating a treatment volume margin.[GRAPHICS]. Show less
Abdel-Kafi, S.; Ridder, M. de; Riva, M. de; Geest, R.J. van der; Rasch, C.; Zeppenfeld, K. 2020
OBJECTIVES This study sought to determine new reference cutoffs for normal unipolar voltage (UV) and bipolar voltage (BV) that would be adjusted for the LV remodeling.BACKGROUND The definition of ... Show moreOBJECTIVES This study sought to determine new reference cutoffs for normal unipolar voltage (UV) and bipolar voltage (BV) that would be adjusted for the LV remodeling.BACKGROUND The definition of "normal" left ventricular (LV) endocardial voltage in patients with post-infarct scar is still lacking. The reference voltage of the noninfarcted myocardium (NIM) may differ between patients depending on LV structural remodeling and the ensuing interstitial fibrosis.METHODS Electroanatomic voltage mapping was integrated with isotropic late gadolinium-enhanced cardiac magnetic resonance in 15 patients with nonremodeted LV and 12 patients with remodeled LV (end-systolic volume index >50 ml/m(2) with ejection fraction <47% assessed by cardiac magnetic resonance). Reference voltages (fifth percentile values) were determined from pooled NIM segments without late gadolinium enhancement.RESULTS The cutoffs for normal BV and UV were >= 3.0 and >= 6.7 mV for nonremodeled LV and >= 2.1 and >= 6.4 mV for remodeled LV. Endocardial low-voltage area (LVA) defined by the adjusted cutoffs corresponded better to late gadolinium enhancement-detected scar than did LVA defined by uniform cutoffs. In 15 patients who underwent successful ablation of ventricular tachycardia, the LVA contained >97% of targeted evoked delayed potentials. Insights from whole-heart T1 mapping revealed more fibrotic NIM in patients with remodeled LV compared with nonremodeled LV.CONCLUSIONS This study found substantial differences in endocardial voltage of NIM in post-infarct patients with remodeled versus nonremodeled LV. The new adjusted cutoffs for "normal" BV and UV enable a patient-tailored approach to etectroanatomic voltage mapping of LV. (C) 2019 by the American College of Cardiology Foundation. Show less