To assess the reproducibility of CT-based Leaman score (CT-LeSc). CT-LeSc can non-invasively quantify total coronary atherosclerotic burden and is an independent long-term predictor of cardiac... Show moreTo assess the reproducibility of CT-based Leaman score (CT-LeSc). CT-LeSc can non-invasively quantify total coronary atherosclerotic burden and is an independent long-term predictor of cardiac events. Its calculation however relies on the subjective assessment of lesions using coronary computed tomography angiography and therefore is subject to intra- and inter-observer variability. Inter-observer reproducibility was assessed by calculating the CT-LeSc in 50 patients randomly selected from the SYNTAX III REVOLUTION and ABSORB trials by two separate teams, each made up of two cardiologists, who reported results by consensus. For intra-observer reproducibility, the CT-LeSc was calculated in same 50 patients on two occasions eight weeks apart, by the same team of two cardiologists. The level of agreement was measured by the weighted kappa statistic, with intra- and inter-observer variability used to evaluate the CT-LeSc’s reproducibility. The variables evaluated by weighted kappa statistics were total number of lesions; number of calcified lesions; number of non-calcified lesions; number of mixed lesions; number of obstructive lesions; number of non-obstructive lesions; and the total CT-LeSc in increments of ten and five. During assessment of inter-observer variability the mean ± standard deviation (SD) CT-LeSc calculated by the first and second team was 15.36 ± 5.57 versus 15.24 ± 5.16. The mean of the differences (precision) was 0.97, with a SD (accuracy) 1.17. The inter-observer variability was lowest for Leaman score in increments of five (weighted kappa 0.93), and highest for the total number of calcified lesions (weighted kappa 0.66). During assessment of intra-observer variability, the mean ± SD CT-LeSc were 16.61 ± 5.28 versus 16.82 ± 5.55. The mean ± SD of the differences was 1.28 ± 1.02. The intra-observer variability was the lowest for Leaman score in increments of five (weighted kappa 0.93), and the highest for the total number of lesions and calcified lesions (weighted kappa 0.65). CT-LeSc has substantial to near-perfect agreement for reproducibility. Show less
Advances in image reconstruction using either single or multimodality imaging data provide increasingly accurate three-dimensional (3D) patient's arterial models for shear stress evaluation using... Show moreAdvances in image reconstruction using either single or multimodality imaging data provide increasingly accurate three-dimensional (3D) patient's arterial models for shear stress evaluation using computational fluid dynamics (CFD). We aim to evaluate the impacts on endothelial shear stress (ESS) derived from a simple image reconstruction using 3D-quantitative coronary angiography (3D-QCA) versus a multimodality reconstruction method using optical coherence tomography (OCT) in patients' vessels treated with bioresorbable scaffolds. Seven vessels at baseline and five-year follow-up of seven patients from a previous CFD investigation were retrospectively selected for a head-to-head comparison of angiography-derived versus OCT-derived ESS. 3D-QCA significantly underestimated the minimum stent area [MSA] (-2.38mm2) and the stent length (-1.46 mm) compared to OCT-fusion method reconstructions. After carefully co-registering the region of interest for all cases with a sophisticated statistical method, the difference in MSA measurements as well as the inability of angiography to visualise the strut footprint in the lumen surface have translated to higher angiography-derived ESS than OCT-derived ESS (1.76 Pa or 1.52 times for the overlapping segment). The difference in ESS widened with a more restricted region of interest (1.97 Pa or 1.63 times within the scaffold segment). Angiography and OCT offer two distinctive methods of ESS calculation. Angiography-derived ESS tends to overestimate the ESS compared to OCT-derived ESS. Further investigations into ESS analysis resolution play a vital role in adopting OCT-derived ESS. Show less
Poon, E.K.W.; Ono, M.; Wu, X.L.; Dijkstra, J.; Sato, Y.; Kutyna, M.; ... ; Serruys, P.W. 2023
Endothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative... Show moreEndothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative coronary artery bypass graft are yet unclear. This report aims to examine the interplay between ESS and the morphological alterations of a biorestorative coronary bypass graft in an animal model. Computational fluid dynamics (CFD) simulation derived from the fusion of angiography and optical coherence tomography (OCT) imaging was used to reconstruct data on the luminal anatomy of a bioresorbable coronary bypass graft with an endoluminal "flap" identified during OCT acquisition. The "flap" compromised the smooth lumen surface and considerably disturbed the local flow, leading to abnormally low ESS and high oscillatory shear stress (OSI) in the vicinity of the "flap". In the presence of the catheter, the flow is more stable (median OSI 0.02384 versus 0.02635, p < 0.0001; maximum OSI 0.4612 versus 0.4837). Conversely, OSI increased as the catheter was withdrawn which can potentially cause back-and-forth motions of the "flap", triggering tissue fatigue failure. CFD analysis in this report provided sophisticated physiological information that complements the anatomic assessment from imaging enabling a complete understanding of biorestorative graft pathophysiology. Show less
OBJECTIVES: This study aimed to investigate the impact of mechanical factors at baseline on the patency of a restorative conduit for coronary bypass grafts in an ovine model at serial follow-up up... Show moreOBJECTIVES: This study aimed to investigate the impact of mechanical factors at baseline on the patency of a restorative conduit for coronary bypass grafts in an ovine model at serial follow-up up to 1 year.METHODS: The analyses of 4 mechanical factors [i.e. bending angle, superficial wall strain and minimum and maximum endothelial shear stress (ESS)] were performed in 3D graft models reconstructed on baseline (1-month) angiograms frame by frame by a core laboratory blinded for the late follow-up. The late patency was documented by Quantitative Flow Ratio (QFR (R)) that reflects the physiological status of the graft. The correlation between 4 mechanical factors and segmental QFR (Delta QFR) were analysed on 10 equal-length segments of each graft.RESULTS: A total of 69 graft geometries of 7 animals were performed in the study. The highest Delta QFR at 12 months was colocalized in segments of the grafts with the largest bending angles at baseline. Higher Delta QFR at 3 months were both at the anastomotic ends and were colocalized with the highest superficial wall strain at baseline. High baseline ESS was topographically associated with higher Delta QFR at the latest follow-up. Correlations of minimum and maximum ESS with Delta QFR at 3 months were the strongest among these parameters (rho = 0.30, 95% CI [-0.05 to 0.56] and rho = 0.27, 95% CI [-0.05 to 0.54], respectively).CONCLUSIONS: Despite the limited number of grafts, this study suggests an association between early abnormal mechanical factors and late flow metrics of the grafts. The understanding of the mechanical characteristics could help to improve this novel conduit. Show less
Wu, X.L.; Ono, M.; Kawashima, H.; Poon, E.K.W.; Torii, R.; Shahzad, A.; ... ; Onuma, Y. 2021
A novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional... Show moreA novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional finite element analysis of cardiovascular biomechanics using the estimated pulsatile pressure, the 4D-SWS approach can calculate the dynamic mechanical state of the superficial wall in vivo, which could be directly linked with plaque rupture or stent fracture. The validation of this approach using in silico models showed that the distribution and maximum values of superficial wall stress were similar to those calculated by conventional finite element analysis. The in vivo deformation was validated on 16 coronary arteries, from the comparison of centerlines predicted by the 4D-SWS approach against the actual centerlines reconstructed from angiograms at a randomly selected time-point, which demonstrated a good agreement of the centerline morphology between both approaches (scaling: 0.995 +/- 0.018 and dissimilarity: 0.007 +/- 0.014). The in silico vessel models with softer plaque and larger plaque burden presented more variation in mean lumen diameter and resulted in higher superficial wall stress. In more than half of the patients (n = 16), the maximum superficial wall stress was found at the proximal lesion shoulder. Additionally, in three patients who later suffered from acute coronary syndrome, the culprit plaque rupture sites co-localized with the site of highest superficial wall stress on their baseline angiography. These representative cases suggest that angiography-based superficial wall dynamics have the potential to identify coronary segments at high-risk of plaque rupture and fracture sites of implanted stents. Ongoing studies are focusing on identifying weak spots in coronary bypass grafts, and on exploring the biomechanical mechanisms of coronary arterial remodeling and aneurysm formation. Future developments involve integration of fast computational techniques to allow online availability of superficial wall strain and stress in the catheterization laboratory. Show less
Aims: The purpose of the Multivessel TALENT trial is to compare clinical outcomes of the novel Supraflex Cruz stent with those of the SYNERGY stent in patients with three-vessel disease (3VD)... Show moreAims: The purpose of the Multivessel TALENT trial is to compare clinical outcomes of the novel Supraflex Cruz stent with those of the SYNERGY stent in patients with three-vessel disease (3VD) undergoing state-of-the-art percutaneous coronary intervention (PCI).Methods and results: In this prospective, randomised, 1:1 balanced, multicentre, open-label trial, 1,550 patients with de novo 3VD without left main disease will be assigned to the Supraflex Cruz or SYNERGY arm. The following treatment principles of "best practice" PCI will be applied: Heart Team consensus based on SYNTAX score II treatment recommendation, functional lesion evaluation by quantitative flow ratio (QFR), stent optimisation by intravascular imaging, optimal pharmacological treatment and prasugrel monotherapy. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any revascularisation, at 12 months post procedure. The powered secondary endpoint is a superiority comparison of the vesseloriented composite endpoint (VOCE), defined as vessel-related cardiovascular death, vessel-related myocardial infarction, or clinically and physiologically indicated target vessel revascularisation, at 24 months.Conclusions: The Multivessel TALENT trial will be evaluating a novel treatment strategy for complex coronary artery disease with state-of-the-art PCI based on angiography-derived QFR with novel ultra-thin Supraflex Cruz stents, compared with SYNERGY stents. Show less
Background and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES)... Show moreBackground and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES) remains elusive. The aim of this study was to determine whether the relationship between ESS and remodeling patterns differs in BRS from those seen in metallic DES at 3-year follow-up.Methods: In the ABSORB II randomized trial, lesions were investigated by serial coronary angiography and intravascular ultrasound (IVUS). Three-dimensional reconstructions of coronary arteries post-procedure and at 3 years were performed. ESS was quantified using non-Newtonian steady flow simulation. IVUS cross-sections in device segment were matched using identical landmarks.Results: Paired ESS calculations post-procedure and at 3 years were feasible in 57 lesions in 56 patients. Post-procedure, median ESS at frame level was higher in BRS than in DES, with marginal statistical significance (0.97 +/- 0.48 vs. 0.75 +/- 0.39 Pa, p = 0.063). In the BRS arm, vessel area and lumen area showed larger increases in the highest tercile of median ESS post-procedure as compared to the lowest tercile. In contrast, in DES, no significant relationship between median ESS post-procedure and remodeling was observed. In multivariate analysis, smaller vessel area, larger lumen area, higher plaque burden post-procedure, and higher median ESS post-procedure were independently associated with expansive remodeling in matched frames. Only in BRS, younger age was an additional significant predictor of expansive remodeling.Conclusions: In a subset of lesions with large plaque burden, shear stress could be associated with expansive remodeling and late lumen enlargement in BRS, while ESS had no impact on vessel dimension in metallic DES. Show less
Studies have shown that the quantitative flow ratio (QFR), recently introduced to assess lesion severity from coronary angiography, provides useful prognostic information; however the additive... Show moreStudies have shown that the quantitative flow ratio (QFR), recently introduced to assess lesion severity from coronary angiography, provides useful prognostic information; however the additive value of this technique over intravascular imaging in detecting lesions that are likely to cause events is yet unclear. We analysed data acquired in the PROSPECT and IBIS-4 studies, in particular the baseline virtual histology-intravascular ultrasound (VH-IVUS) and angiographic data from 17 non-culprit lesions with a presumable vulnerable phenotype (i.e., thin or thick cap fibroatheroma) that caused major adverse cardiac events or required revascularization (MACE) at 5-year follow-up and from a group of 78 vulnerable plaques that remained quiescent. The segments studied by VH-IVUS were identified in coronary angiography and the QFR was estimated. The additive value of 3-dimensional quantitative coronary angiography (3D-QCA) and of the QFR in predicting MACE at 5 year follow-up beyond plaque characteristics was examined. It was found that MACE lesions had a greater plaque burden (PB) and smaller minimum lumen area (MLA) on VH-IVUS, a longer length and a smaller minimum lumen diameter (MLD) on 3D-QCA and a lower QFR compared with lesions that remained quiescent. By univariate analysis MLA, PB, MLD, lesion length on 3D-QCA and QFR were predictors of MACE. In multivariate analysis a low but normal QFR (> 0.80 to < 0.97) was the only independent prediction of MACE (HR 3.53, 95% CI 1.16-10.75; P = 0.027). In non-flow limiting lesions with a vulnerable phenotype, QFR may provide additional prognostic information beyond plaque morphology for predicting MACE throughout 5 years. Show less
Aims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES... Show moreAims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES) in porcine coronary arteries.Methods and results: In 15 non-atherosclerotic Yucatan mini pigs, the ArterioSorb (3.0/14 mm) and XIENCE (3.0/15 mm) were implanted in 25 and 15 vessels, respectively. Acute performance was evaluated by using quantitative coronary angiography (QCA) and optical coherence tomography (OCT). Following three-dimensional reconstruction of the coronary arteries, endothelial shear stress (ESS) was quantified using non-Newtonian steady-flow simulation. Acute recoil measured by QCA was comparable in the two aims. Post-procedural flow and scaffold/stent area by OCT did not differ between the two devices. ESS post procedure was comparable between ArterioSorb and XIENCE (2.21 +/- 1.97 vs 2.25 +/- 1.71 Pa, p=0.314).Conclusions: Acute recoil, luminal dimensions and ESS in the ArterioSorb oriented PLLA scaffold with thin struts of 95 mu m were comparable to those in the XIENCE metallic DES. Show less
OBJECTIVES The aim of this study was to investigate the impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) on clinical outcomes in patients with de novo 3-vessel... Show moreOBJECTIVES The aim of this study was to investigate the impact of post-percutaneous coronary intervention (PCI) quantitative flow ratio (QFR) on clinical outcomes in patients with de novo 3-vessel disease (3VD) treated with contemporary PCI.BACKGROUND The clinical impact of post-PCI QFR in patients treated with state-of-the-art PCI for de novo 3VD is undetermined.METHODS All vessels treated in the SYNTAX (SYNergy between percutaneous coronary intervention with TAXus and cardiac surgery) II trial were retrospectively screened and analyzed for post-PCI QFR. The primary endpoint of this substudy was vessel-oriented composite endpoint (VOCE) at 2 years, defined as the composite of vessel-related cardiac death, vessel-related myocardial infarction, and target vessel revascularization. The receiver-operating characteristic curve was used to calculate the optimal cutoff value of post-PCI QFR for predicting 2-year VOCE. All the analyzable vessels were stratified on the basis of the optimal cutoff value.RESULTS A total of 968 vessels treated with PCI were screened. Post-PCIQFR was analyzable in 771 (79.6%) vessels. A total of 52 (6.7%) VOCEs occurredat 2 years. The mean value of post-PCIQFR was 0.91 +/- 0.07. The diagnostic performance of post-PCI QFR to predict 2-year VOCE was moderate (area under the curve: 0.702; 95% confidence interval: 0.633 to 0.772), with the optimal cutoff value of post-PCI QFR for predicting 2-year VOCE 0.91 (sensitivity 0.652, specificity 0.635). The incidence of 2-year VOCE in the vessels with post-PCIQFR<0.91 (n = 284) was significantly higher compared with vessels with post-PCI QFR >= 0.91 (n = 487) (12.0% vs. 3.7%; hazard ratio: 3.37; 95% confidence interval: 1.91 to 5.97; p < 0.001).CONCLUSIONS A higher post-PCI QFR value is associated with improved vessel-related clinical outcomes in state-of the art PCI practice for de novo 3VD. Achieving a post-PCI QFR value >= 0.91 in all treated vessels should be a target when treating de novo 3VD. These findings require confirmation in future prospective trials. (C) 2019 by the American College of Cardiology Foundation. Show less
Optical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to... Show moreOptical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to investigate the in-vivo effect of strut thickness and strut protrusion on endothelial wall shear stress (ESS) distribution in ArterioSorb Absorbable Drug-Eluting Scaffold (ArterioSorb) and Absorb everolimus-eluting Bioresorbable Vascular Scaffold (Absorb) devices that struts with similar morphology (quadratic structure) but different thickness. In three animals, six coronary arteries were treated with ArterioSorb. At different six animals, six coronary arteries were treated with Absorb. Following three-dimensional(3D) reconstruction of the coronary arteries, Newtonian steady flow simulation was performed and the ESS were estimated. Mixed effects models were used to compare ESS distribution in the two devices. There were 4591 struts in the analyzed 477 cross-sections in Absorb (strut thickness=157 mu m) and 3105 struts in 429 cross-sections in ArterioSorb (strut thickness=95 mu m) for the protrusion analysis. In cross-section level analysis, there was significant difference between the scaffolds in the protrusion distances. The protrusion was higher in Absorb (97% of the strut thickness) than in ArterioSorb (88% of the strut thickness). ESS was significantly higher in ArterioSorb (1.52 +/- 0.34Pa) than in Absorb (0.73 +/- 2.19Pa) (p=0.001). Low- and very-low ESS data were seen more often in Absorb than in ArterioSorb. ArterioSorb is associated with a more favorable ESS distribution compared to the Absorb. These differences should be attributed to different strut thickness/strut protrusion that has significant effect on shear stress distribution. Show less
OBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX ... Show moreOBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score derived from QFR (fSS(QFR)) on clinical outcomes.BACKGROUND The applicability of QFR in patients with 3-vessel disease and the feasibility of fSS(QFR) have not yet been investigated.METHODS All lesions interrogated using instantaneous wave-free ratio and/or fractional flow reserve in the SYNTAX II trial were retrospectively screened and analyzed for QFR. The diagnostic performance of QFR was investigated using hybrid wire-derived pressure assessment (instantaneous wave-free ratio and fractional flow reserve), used in the trial as a reference. Patients with analyzable QFR in 3 vessels were stratified according to fSS(QFR) to evaluate its clinical prognostic value on the basis of 2-year patient-oriented composite endpoint.RESULTS QFRs were analyzable in 71.0% of lesions (836 lesions). The diagnostic performance of QFR to predict binary wire-based ischemia was substantial (area under the curve 0.81, accuracy 73.8%), with a positive predictive value of 85.9%. Independent predictors of diagnostic discordance were lesions in side branches, involvement of bifurcation or trifurcation, and small vessel. According to the 2-year patient-oriented composite endpoint, fSS(QFR) reclassified 26.1% of the patients (36 of 138) in the high-to intermediate-risk group into the low-risk group appropriately (net reclassification improvement 0.32; p < 0.001). The area under the curve for fSS(QFR) to predict the 2-year patient-oriented composite endpoint was higher than that of the classic anatomic SYNTAX score (0.68 vs. 0.56; p = 0.002).CONCLUSIONS QFR demonstrated substantial applicability in patients with 3-vessel disease. The fSS(QFR) has the potential to further refine prognostic risk estimation compared with the classic anatomic SYNTAX score. (c) 2019 by the American College of Cardiology Foundation. Show less