To assess the reproducibility of CT-based Leaman score (CT-LeSc). CT-LeSc can non-invasively quantify total coronary atherosclerotic burden and is an independent long-term predictor of cardiac... Show moreTo assess the reproducibility of CT-based Leaman score (CT-LeSc). CT-LeSc can non-invasively quantify total coronary atherosclerotic burden and is an independent long-term predictor of cardiac events. Its calculation however relies on the subjective assessment of lesions using coronary computed tomography angiography and therefore is subject to intra- and inter-observer variability. Inter-observer reproducibility was assessed by calculating the CT-LeSc in 50 patients randomly selected from the SYNTAX III REVOLUTION and ABSORB trials by two separate teams, each made up of two cardiologists, who reported results by consensus. For intra-observer reproducibility, the CT-LeSc was calculated in same 50 patients on two occasions eight weeks apart, by the same team of two cardiologists. The level of agreement was measured by the weighted kappa statistic, with intra- and inter-observer variability used to evaluate the CT-LeSc’s reproducibility. The variables evaluated by weighted kappa statistics were total number of lesions; number of calcified lesions; number of non-calcified lesions; number of mixed lesions; number of obstructive lesions; number of non-obstructive lesions; and the total CT-LeSc in increments of ten and five. During assessment of inter-observer variability the mean ± standard deviation (SD) CT-LeSc calculated by the first and second team was 15.36 ± 5.57 versus 15.24 ± 5.16. The mean of the differences (precision) was 0.97, with a SD (accuracy) 1.17. The inter-observer variability was lowest for Leaman score in increments of five (weighted kappa 0.93), and highest for the total number of calcified lesions (weighted kappa 0.66). During assessment of intra-observer variability, the mean ± SD CT-LeSc were 16.61 ± 5.28 versus 16.82 ± 5.55. The mean ± SD of the differences was 1.28 ± 1.02. The intra-observer variability was the lowest for Leaman score in increments of five (weighted kappa 0.93), and the highest for the total number of lesions and calcified lesions (weighted kappa 0.65). CT-LeSc has substantial to near-perfect agreement for reproducibility. Show less
Advances in image reconstruction using either single or multimodality imaging data provide increasingly accurate three-dimensional (3D) patient's arterial models for shear stress evaluation using... Show moreAdvances in image reconstruction using either single or multimodality imaging data provide increasingly accurate three-dimensional (3D) patient's arterial models for shear stress evaluation using computational fluid dynamics (CFD). We aim to evaluate the impacts on endothelial shear stress (ESS) derived from a simple image reconstruction using 3D-quantitative coronary angiography (3D-QCA) versus a multimodality reconstruction method using optical coherence tomography (OCT) in patients' vessels treated with bioresorbable scaffolds. Seven vessels at baseline and five-year follow-up of seven patients from a previous CFD investigation were retrospectively selected for a head-to-head comparison of angiography-derived versus OCT-derived ESS. 3D-QCA significantly underestimated the minimum stent area [MSA] (-2.38mm2) and the stent length (-1.46 mm) compared to OCT-fusion method reconstructions. After carefully co-registering the region of interest for all cases with a sophisticated statistical method, the difference in MSA measurements as well as the inability of angiography to visualise the strut footprint in the lumen surface have translated to higher angiography-derived ESS than OCT-derived ESS (1.76 Pa or 1.52 times for the overlapping segment). The difference in ESS widened with a more restricted region of interest (1.97 Pa or 1.63 times within the scaffold segment). Angiography and OCT offer two distinctive methods of ESS calculation. Angiography-derived ESS tends to overestimate the ESS compared to OCT-derived ESS. Further investigations into ESS analysis resolution play a vital role in adopting OCT-derived ESS. Show less
Nabeta, T.; Meucci, M.C.; Westenberg, J.J.M.; Reiber, J.H.C.; Knuuti, J.; Bijl, P. van der; ... ; Bax, J.J. 2023
Risk stratification of patients with ischemic heart disease (IHD) still depends mainly on the left ventricular ejection fraction (LVEF). LV inward displacement (InD) is a novel parameter of LV... Show moreRisk stratification of patients with ischemic heart disease (IHD) still depends mainly on the left ventricular ejection fraction (LVEF). LV inward displacement (InD) is a novel parameter of LV systolic function, derived from feature tracking cardiac magnetic resonance (CMR) imaging. We aimed to investigate the prognostic impact of InD in patients with IHD and prior myocardial infarction. A total of 111 patients (mean age 57 +/- 10, 86% male) with a history of myocardial infarction who underwent CMR were included. LV InD was quantified by measuring the displacement of endocardially tracked points towards the centreline of the LV during systole with feature tracking CMR. The endpoint was a composite of all-cause mortality, heart failure hospitalization and arrhythmic events. During a median follow-up of 142 (IQR 107-159) months, 31 (27.9%) combined events occurred. Kaplan-Meier analysis demonstrated that patients with LV InD below the study population median value (23.0%) had a significantly lower event-free survival (P < 0.001). LV InD remained independently associated with outcomes (HR 0.90, 95% CI 0.84-0.98, P = 0.010) on multivariate Cox regression analysis. InD also provided incremental prognostic value to LVEF, LV global radial strain and CMR scar burden. LV InD, measured with feature tracking CMR, was independently associated with outcomes in patients with IHD and prior myocardial infarction. LV InD also provided incremental prognostic value, in addition to LVEF and LV global radial strain. LV InD holds promise as a pragmatic imaging biomarker for post-infarct risk stratification. Show less
Background: Advances in coronary computed tomography angiography (CCTA) reconstruction algorithms are expected to enhance the accuracy of CCTA plaque quantification. We aim to evaluate different... Show moreBackground: Advances in coronary computed tomography angiography (CCTA) reconstruction algorithms are expected to enhance the accuracy of CCTA plaque quantification. We aim to evaluate different CCTA recon-struction approaches in assessing vessel characteristics in coronary atheroma using intravascular ultrasound (IVUS) as the reference standard.Methods: Matched cross-sections (n = 7241) from 50 vessels in 15 participants with chronic coronary syndrome who prospectively underwent CCTA and 3-vessel near-infrared spectroscopy-IVUS were included. Twelve CCTA datasets per patient were reconstructed using two different kernels, two slice thicknesses (0.75 mm and 0.50 mm) and three different strengths of advanced model-based iterative reconstruction (IR) algorithms. Lumen and vessel wall borders were manually annotated in every IVUS and CCTA cross-section which were co-registered using dedicated software. Image quality was sub-optimal in the reconstructions with a sharper kernel, so these were excluded. Intraclass correlation coefficient (ICC) and repeatability coefficient (RC) were used to compare the estimations of the 6 CT reconstruction approaches with those derived by IVUS.Results: Segment-level analysis showed good agreement between CCTA and IVUS for assessing atheroma volume with approach 0.50/5 (slice thickness 0.50 mm and highest strength 5 ADMIRE IR) being the best (total atheroma volume ICC: 0.91, RC: 0.67, p < 0.001 and percentage atheroma volume ICC: 0.64, RC: 14.06, p < 0.001). At lesion-level, there was no difference between the CCTA reconstructions for detecting plaques (accuracy range: 0.64-0.67; p = 0.23); however, approach 0.50/5 was superior in assessing IVUS-derived lesion characteristics associated with plaque vulnerability (minimum lumen area ICC: 0.64, RC: 1.31, p < 0.001 and plaque burden ICC: 0.45, RC: 32.0, p < 0.001).Conclusion: CCTA reconstruction with thinner slice thickness, smooth kernel and highest strength advanced IR enabled more accurate quantification of the lumen and plaque at a segment-, and lesion-level analysis in coronary atheroma when validated against intravascular ultrasound. Clinicaltrials.gov (NCT03556644) Show less
Poon, E.K.W.; Ono, M.; Wu, X.L.; Dijkstra, J.; Sato, Y.; Kutyna, M.; ... ; Serruys, P.W. 2023
Endothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative... Show moreEndothelial shear stress (ESS) plays a key role in the clinical outcomes in native and stented segments; however, their implications in bypass grafts and especially in a synthetic biorestorative coronary artery bypass graft are yet unclear. This report aims to examine the interplay between ESS and the morphological alterations of a biorestorative coronary bypass graft in an animal model. Computational fluid dynamics (CFD) simulation derived from the fusion of angiography and optical coherence tomography (OCT) imaging was used to reconstruct data on the luminal anatomy of a bioresorbable coronary bypass graft with an endoluminal "flap" identified during OCT acquisition. The "flap" compromised the smooth lumen surface and considerably disturbed the local flow, leading to abnormally low ESS and high oscillatory shear stress (OSI) in the vicinity of the "flap". In the presence of the catheter, the flow is more stable (median OSI 0.02384 versus 0.02635, p < 0.0001; maximum OSI 0.4612 versus 0.4837). Conversely, OSI increased as the catheter was withdrawn which can potentially cause back-and-forth motions of the "flap", triggering tissue fatigue failure. CFD analysis in this report provided sophisticated physiological information that complements the anatomic assessment from imaging enabling a complete understanding of biorestorative graft pathophysiology. Show less
Background:Pericoronary adipose tissue (PCAT) attenuation has been associated with coronary inflammation and can be evaluated with coronary computed tomography angiography. The aims of this study... Show moreBackground:Pericoronary adipose tissue (PCAT) attenuation has been associated with coronary inflammation and can be evaluated with coronary computed tomography angiography. The aims of this study were to compare the PCAT attenuation across precursors of culprit and nonculprit lesions of patients with acute coronary syndrome versus stable coronary artery disease (CAD).Methods: In this case-control study, patients with suspected CAD who underwent coronary computed tomography angiography were included. Patients who developed an acute coronary syndrome within 2 years after the coronary computed tomography angiography scan were identified, and patients with stable CAD (defined as any coronary plaque >= 30% luminal diameter stenosis) were 1:2 propensity score matched for age, sex, and cardiac risk factors. The mean PCAT attenuation was analyzed at lesion level and compared between precursors of culprit lesions, nonculprit lesions, and stable coronary plaques.Results: In total, 198 patients (age 62 +/- 10 years, 65% male) were selected, including 66 patients who developed an acute coronary syndrome and 132 propensity matched patients with stable CAD. Overall, 765 coronary lesions were analyzed (culprit lesion precursors: n=66; nonculprit lesion precursors: n=207; and stable lesions: n=492). Culprit lesion precursors had larger total plaque volume, fibro-fatty plaque volume, and low-attenuation plaque volume compared to nonculprit and stable lesions. The mean PCAT attenuation was significantly higher across culprit lesion precursors compared to nonculprit and stable lesions (-63.8 +/- 9.7 Hounsfield units versus -68.8 +/- 10.6 Hounsfield units versus -69.6 +/- 10.6 Hounsfield units, respectively; P<0.001), whereas the mean PCAT attenuation around nonculprit and stable lesions was not significantly different (P=0.99).Conclusions: The mean PCAT attenuation is significantly increased across culprit lesion precursors in patients with acute coronary syndrome, compared to nonculprit lesions of these patients and to lesions of patients with stable CAD, which may suggest a higher intensity of inflammation. PCAT attenuation on coronary computed tomography angiography may be a novel marker to identify high-risk plaques. Show less
Hemodynamic force (HDF) analysis represents a novel approach to quantify intraventricular pressure gradients, responsible for blood flow. A new mathematical model allows the derivation of HDF... Show moreHemodynamic force (HDF) analysis represents a novel approach to quantify intraventricular pressure gradients, responsible for blood flow. A new mathematical model allows the derivation of HDF parameters from routine transthoracic echocardiography, making this tool more accessible for clinical use. HDF analysis is considered the fluid dynamics correlate of deformation imaging and may be even more sensitive to detect mechanical abnormalities. This has the potential to add incremental clinical value, allowing earlier detection of pathology or immediate evaluation of response to treatment. In this article, the theoretical background and physiological patterns of HDF in the left ventricle are provided. In pathological situations, the HDF pattern might alter, which is illustrated with a case of ST segment elevation myocardial infarction and non-ischemic cardiomyopathy with typical left bundle branch block. Show less
Smit, J.M.; Mahdiui, M. el; Graaf, M.A. de; Montero-Cabezas, J.M.; Reiber, J.H.C.; Jukema, J.W.; ... ; Bax, J.J. 2022
Coronary plaque composition may play an important role in the induction of myocardial ischemia. Our objective was to further clarify the relation between coronary plaque composition and myocardial ...Show moreCoronary plaque composition may play an important role in the induction of myocardial ischemia. Our objective was to further clarify the relation between coronary plaque composition and myocardial ischemiain patients with chest pain symptoms. The study population consisted of 103 patients who presented to the outpatient clinic or emergency department with chest pain symptoms and were referred for diagnostic invasivecoronary angiography. Intravascular ultrasound virtual histology was used for the assessment of coronary plaque composition. A noncalcified plaque was defined as a combination of necrotic core and fibrofatty tissue. Quantitative flow ratio (QFR), which is a coronary angiography-based technique used to calculate fractional flow reserve without the need for hyperemia induction or for a pressure wire, was used as the reference standard for the evaluation of myocardial ischemia. Coronary artery plaques with QFR of ≤0.80 were considered abnormal—that is, ischemia-generating. In total, 149 coronary plaques were analyzed, 21 of which (14%) were considered abnormal according to QFR. The percentage of noncalcified tissue was significantly higher in plaques with abnormal QFR (38.2 ± 6.5% vs 33.1 ± 9.0%, p = 0.014). After univariable analysis, both plaque load (odds ratio [OR] per 1% increase 1.081, p <0.001) and the percentage of noncalcified tissue (OR per 1% increase 1.070, p = 0.020) were significantly associated with reduced QFR. However, after multivariable analysis, only plaque load remained significantly associated with abnormal QFR (OR per 1% increase 1.072, p <0.001). In conclusion, the noncalcified plaque area was significantly higher in hemodynamically significant coronary lesions than in nonsignificant lesions. Although an increase in the noncalcified plaque area was significantly associated with a reduced QFR, this association lost significance after adjustment for localized plaque load. Show less
BACKGROUND The association between the change in vessel inflammation, as quantified by perivascular adipose tissue (PVAT) density, and the progression of coronary atherosclerosis remains to be... Show moreBACKGROUND The association between the change in vessel inflammation, as quantified by perivascular adipose tissue (PVAT) density, and the progression of coronary atherosclerosis remains to be determined.OBJECTIVES The purpose of this study was to explore the association between the change in PVAT density and the progression of total and compositional plaque volume (PV). METHODS Patients were selected from a prospective multinational registry. Patients who underwent serial coronary computed tomography angiography studies with $2-year intervals and were scanned with the same tube voltage at baseline and follow-up were included. Total and compositional PV and PVAT density at baseline and follow-up were quantitatively analyzed for every lesion. Multivariate linear regression models using cluster analyses were constructed.RESULTS A total of 1,476 lesions were identified from 474 enrolled patients (mean age 61.2 +/- 9.3 years; 65.0% men). The mean PVAT density was-74.1 +/- 11.5 HU, and total PV was 48.1 +/- 83.5 mm3 (19.2 +/- 44.8 mm3 of calcified PV and 28.9 +/- 51.0 mm3 of noncalcified PV). On multivariate analysis (adjusted for clinical risk factors, medication use, change in lipid levels, total PV at baseline, luminal HU attenuation, location of lesions, and tube voltage), the increase in PVAT density was positively associated with the progression of total PV (estimate = 0.275 [95% CI: 0.004-0.545]; P = 0.047), driven by the association with fibrous PV (estimate = 0.245 [95% CI: 0.070-0.420]; P = 0.006). Calcified PV progression was not associated with the increase in PVAT density (P > 0.050). CONCLUSIONS Increase in vessel inflammation represented by PVAT density is independently associated with the progression of the lipid component of coronary atherosclerotic plaques. (Progression of AtheRosclerotic PlAque Deter-mIned by Computed TomoGraphic Angiography Imaging [PARADIGM]; NCT02803411) (J Am Coll Cardiol Img 2022;15:1760-1767) (c) 2022 by the American College of Cardiology Foundation. Show less
Rosendael, S.E. van; Kuneman, J.H.; Hoogen, I.J. van den; Kitslaar, P.H.; Rosendael, A.R. van; Bijl, P. van der; ... ; Bax, J.J. 2022
Pericoronary adipose tissue (PCAT) attenuation, derived from coronary computed tomography angiography (CCTA), is associated with coronary artery inflammation. Values for PCAT attenuation in men and... Show morePericoronary adipose tissue (PCAT) attenuation, derived from coronary computed tomography angiography (CCTA), is associated with coronary artery inflammation. Values for PCAT attenuation in men and women without atherosclerosis on CCTA are lacking. The aim of the current study was to assess the mean PCAT attenuation in individuals without coronary artery atherosclerosis on CCTA. Data on PCAT attenuation in men and women without coronary artery atherosclerosis on CCTA were included in this retrospective analysis. The PCAT attenuation was analyzed from the proximal part of the right coronary artery (RCA), the left anterior descending artery (LAD), and the left circumflex artery (LCx). For patient level analyses the mean PCAT attenuation was defined as the mean of the three coronary arteries. In 109 individuals (mean age 45 +/- 13 years; 44% men), 320 coronary arteries were analyzed. The mean PCAT attenuation of the overall population was - 64.4 +/- 8.0 HU. The mean PCAT attenuation was significantly lower in the LAD compared with the LCx and RCA (- 67.8 +/- 7.8 HU vs - 62.6 +/- 6.8 HU vs - 63.6 +/- 7.9 HU, respectively, p < 0.001). In addition, the mean PCAT attenuation was significantly higher in men vs. women in all three coronary arteries (LAD: - 65.7 +/- 7.6 HU vs - 69.4 +/- 7.6 HU, p = 0.014; LCx: - 60.6 +/- 7.4 HU vs - 64.3 +/- 5.9 HU, p = 0.008; RCA: -61.7 +/- 7.9 HU vs - 65.0 +/- 7.7 HU, p = 0.029, respectively). The current study provides mean PCAT attenuation values, derived from individuals without CAD. Moreover, the mean PCAT attenuation is lower in women vs. men. Furthermore, the mean PCAT attenuation is significantly lower in the LAD vs LCx and RCA. Show less
Hirasawa, K.; Singh, G.K.; Kuneman, J.H.; Gegenava, T.; Kley, F. van der; Hautemann, D.; ... ; Delgado, V. 2022
Aims: Aortic stenosis (AS) induces left atrial (LA) remodelling through the increase of left ventricular (LV) filling pressures. Peak LA longitudinal strain (PALS), reflecting LA reservoir function... Show moreAims: Aortic stenosis (AS) induces left atrial (LA) remodelling through the increase of left ventricular (LV) filling pressures. Peak LA longitudinal strain (PALS), reflecting LA reservoir function, has been proposed as a prognostic marker in patients with AS. Feature-tracking (FT) multi-detector computed tomography (MDCT) allows assessment of LA strain from MDCT data. The aim of this study is to investigate the association between PALS using FT MDCT and survival in patients with severe AS who underwent transcatheter aortic valve implantation (TAVI). Methods and results: A total of 376 patients (mean age 80 +/- 7 years, 53% male) who underwent MDCT before TAVI and had suitable data for assessment of PALS using dedicated FT software, were included. The patients were classified into four groups according to PALS quartiles; PALS > 19.3% (Q1, highest reservoir function), 15.0-19.3% (Q2), 9.1-14.9% (Q3), and <= 9.0% (Q4, lowest reservoir function). The primary outcome was all-cause mortality. During a median of 45 (22-68) months follow-up, 148 patients (39%) died. On multivariable Cox regression analysis, PALS was independently associated with all-cause mortality [hazard ratio (HR): 1.044, 95% confidence interval (CI): 1.012-1.076, P = 0.006]. Compared with patients in Q1, patients in Q3 and Q4 were associated with higher risk of mortality after TAVI [HR: 2.262 (95% CI: 1.335-3.832), P = 0.002 for Q3, HR: 3.116 (95% CI: 1.864-5.210), P < 0.001 for Q4]. Conclusion: PALS assessed with FT MDCT is independently associated with all-cause mortality after TAVI. Show less
Wu, X.L.; Ono, M.; Kawashima, H.; Poon, E.K.W.; Torii, R.; Shahzad, A.; ... ; Onuma, Y. 2021
A novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional... Show moreA novel method for four-dimensional superficial wall strain and stress (4D-SWS) is derived from the arterial motion as pictured by invasive coronary angiography. Compared with the conventional finite element analysis of cardiovascular biomechanics using the estimated pulsatile pressure, the 4D-SWS approach can calculate the dynamic mechanical state of the superficial wall in vivo, which could be directly linked with plaque rupture or stent fracture. The validation of this approach using in silico models showed that the distribution and maximum values of superficial wall stress were similar to those calculated by conventional finite element analysis. The in vivo deformation was validated on 16 coronary arteries, from the comparison of centerlines predicted by the 4D-SWS approach against the actual centerlines reconstructed from angiograms at a randomly selected time-point, which demonstrated a good agreement of the centerline morphology between both approaches (scaling: 0.995 +/- 0.018 and dissimilarity: 0.007 +/- 0.014). The in silico vessel models with softer plaque and larger plaque burden presented more variation in mean lumen diameter and resulted in higher superficial wall stress. In more than half of the patients (n = 16), the maximum superficial wall stress was found at the proximal lesion shoulder. Additionally, in three patients who later suffered from acute coronary syndrome, the culprit plaque rupture sites co-localized with the site of highest superficial wall stress on their baseline angiography. These representative cases suggest that angiography-based superficial wall dynamics have the potential to identify coronary segments at high-risk of plaque rupture and fracture sites of implanted stents. Ongoing studies are focusing on identifying weak spots in coronary bypass grafts, and on exploring the biomechanical mechanisms of coronary arterial remodeling and aneurysm formation. Future developments involve integration of fast computational techniques to allow online availability of superficial wall strain and stress in the catheterization laboratory. Show less
Aims: The purpose of the Multivessel TALENT trial is to compare clinical outcomes of the novel Supraflex Cruz stent with those of the SYNERGY stent in patients with three-vessel disease (3VD)... Show moreAims: The purpose of the Multivessel TALENT trial is to compare clinical outcomes of the novel Supraflex Cruz stent with those of the SYNERGY stent in patients with three-vessel disease (3VD) undergoing state-of-the-art percutaneous coronary intervention (PCI).Methods and results: In this prospective, randomised, 1:1 balanced, multicentre, open-label trial, 1,550 patients with de novo 3VD without left main disease will be assigned to the Supraflex Cruz or SYNERGY arm. The following treatment principles of "best practice" PCI will be applied: Heart Team consensus based on SYNTAX score II treatment recommendation, functional lesion evaluation by quantitative flow ratio (QFR), stent optimisation by intravascular imaging, optimal pharmacological treatment and prasugrel monotherapy. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any revascularisation, at 12 months post procedure. The powered secondary endpoint is a superiority comparison of the vesseloriented composite endpoint (VOCE), defined as vessel-related cardiovascular death, vessel-related myocardial infarction, or clinically and physiologically indicated target vessel revascularisation, at 24 months.Conclusions: The Multivessel TALENT trial will be evaluating a novel treatment strategy for complex coronary artery disease with state-of-the-art PCI based on angiography-derived QFR with novel ultra-thin Supraflex Cruz stents, compared with SYNERGY stents. Show less
Background and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES)... Show moreBackground and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES) remains elusive. The aim of this study was to determine whether the relationship between ESS and remodeling patterns differs in BRS from those seen in metallic DES at 3-year follow-up.Methods: In the ABSORB II randomized trial, lesions were investigated by serial coronary angiography and intravascular ultrasound (IVUS). Three-dimensional reconstructions of coronary arteries post-procedure and at 3 years were performed. ESS was quantified using non-Newtonian steady flow simulation. IVUS cross-sections in device segment were matched using identical landmarks.Results: Paired ESS calculations post-procedure and at 3 years were feasible in 57 lesions in 56 patients. Post-procedure, median ESS at frame level was higher in BRS than in DES, with marginal statistical significance (0.97 +/- 0.48 vs. 0.75 +/- 0.39 Pa, p = 0.063). In the BRS arm, vessel area and lumen area showed larger increases in the highest tercile of median ESS post-procedure as compared to the lowest tercile. In contrast, in DES, no significant relationship between median ESS post-procedure and remodeling was observed. In multivariate analysis, smaller vessel area, larger lumen area, higher plaque burden post-procedure, and higher median ESS post-procedure were independently associated with expansive remodeling in matched frames. Only in BRS, younger age was an additional significant predictor of expansive remodeling.Conclusions: In a subset of lesions with large plaque burden, shear stress could be associated with expansive remodeling and late lumen enlargement in BRS, while ESS had no impact on vessel dimension in metallic DES. Show less
Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance ofepicardial coronary stenosis.... Show moreFractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance ofepicardial coronary stenosis. Despite the overall trend towards more physiology-guided revasculari-zati-on, there remains a gap, between guideline recommendations and the clinical adoption of functional evaItAatiorl of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologi'es, we sought to highlight the pri'nci'ples, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization Laboratory. Computational FFR has the potential to ex Pand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes. Show less
Biomarkers of aging are urgently needed to identify individuals at high risk of developing age-associated disease or disability. Growing evidence from population-based studies points to whole-body... Show moreBiomarkers of aging are urgently needed to identify individuals at high risk of developing age-associated disease or disability. Growing evidence from population-based studies points to whole-body magnetic resonance imaging's (MRI) enormous potential for quantifying subclinical disease burden and for assessing changes that occur with aging in all organ systems. The Aging Imageomics Study aims to identify biomarkers of human aging by analyzing imaging, biopsychosocial, cardiovascular, metabolomic, lipidomic, and microbiome variables. This study recruited 1030 participants aged >= 50 years (mean 67, range 50-96 years) that underwent structural and functional MRI to evaluate the brain, large blood vessels, heart, abdominal organs, fat, spine, musculoskeletal system and ultrasonography to assess carotid intima-media thickness and plaques. Patients were notified of incidental findings detected by a certified radiologist when necessary. Extensive data were also collected on anthropometrics, demographics, health history, neuropsychology, employment, income, family status, exposure to air pollution and cardiovascular status. In addition, several types of samples were gathered to allow for microbiome, metabolomic and lipidomic profiling. Using big data techniques to analyze all the data points from biological phenotyping together with health records and lifestyle measures, we aim to cultivate a deeper understanding about various biological factors (and combinations thereof) that underlie healthy and unhealthy aging. Show less
Studies have shown that the quantitative flow ratio (QFR), recently introduced to assess lesion severity from coronary angiography, provides useful prognostic information; however the additive... Show moreStudies have shown that the quantitative flow ratio (QFR), recently introduced to assess lesion severity from coronary angiography, provides useful prognostic information; however the additive value of this technique over intravascular imaging in detecting lesions that are likely to cause events is yet unclear. We analysed data acquired in the PROSPECT and IBIS-4 studies, in particular the baseline virtual histology-intravascular ultrasound (VH-IVUS) and angiographic data from 17 non-culprit lesions with a presumable vulnerable phenotype (i.e., thin or thick cap fibroatheroma) that caused major adverse cardiac events or required revascularization (MACE) at 5-year follow-up and from a group of 78 vulnerable plaques that remained quiescent. The segments studied by VH-IVUS were identified in coronary angiography and the QFR was estimated. The additive value of 3-dimensional quantitative coronary angiography (3D-QCA) and of the QFR in predicting MACE at 5 year follow-up beyond plaque characteristics was examined. It was found that MACE lesions had a greater plaque burden (PB) and smaller minimum lumen area (MLA) on VH-IVUS, a longer length and a smaller minimum lumen diameter (MLD) on 3D-QCA and a lower QFR compared with lesions that remained quiescent. By univariate analysis MLA, PB, MLD, lesion length on 3D-QCA and QFR were predictors of MACE. In multivariate analysis a low but normal QFR (> 0.80 to < 0.97) was the only independent prediction of MACE (HR 3.53, 95% CI 1.16-10.75; P = 0.027). In non-flow limiting lesions with a vulnerable phenotype, QFR may provide additional prognostic information beyond plaque morphology for predicting MACE throughout 5 years. Show less
Aims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES... Show moreAims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES) in porcine coronary arteries.Methods and results: In 15 non-atherosclerotic Yucatan mini pigs, the ArterioSorb (3.0/14 mm) and XIENCE (3.0/15 mm) were implanted in 25 and 15 vessels, respectively. Acute performance was evaluated by using quantitative coronary angiography (QCA) and optical coherence tomography (OCT). Following three-dimensional reconstruction of the coronary arteries, endothelial shear stress (ESS) was quantified using non-Newtonian steady-flow simulation. Acute recoil measured by QCA was comparable in the two aims. Post-procedural flow and scaffold/stent area by OCT did not differ between the two devices. ESS post procedure was comparable between ArterioSorb and XIENCE (2.21 +/- 1.97 vs 2.25 +/- 1.71 Pa, p=0.314).Conclusions: Acute recoil, luminal dimensions and ESS in the ArterioSorb oriented PLLA scaffold with thin struts of 95 mu m were comparable to those in the XIENCE metallic DES. Show less
Kishi, S.; Magalhaes, T.A.; Cerci, R.J.; Zimmermann, E.; Matheson, M.B.; Vavere, A.; ... ; Arbab-Zadeh, A. 2020
Purpose To provide comparative prognostic information of coronary atherosclerotic plaque volume and stenosis assessment in patients with suspected coronary artery disease (CAD). Methods We followed... Show morePurpose To provide comparative prognostic information of coronary atherosclerotic plaque volume and stenosis assessment in patients with suspected coronary artery disease (CAD). Methods We followed 372 patients with suspected or known CAD enrolled in the CORE320 study for 2 years after baseline 320-detector row cardiac CT scanning and invasive quantitative coronary angiography (QCA). CT images were analyzed for coronary calcium scanning (CACS), semi-automatically derived total percent atheroma volume (PAV), segment stenosis score (SSS), in addition to traditional stenosis assessment (>= 50%) by CT and QCA for (1) 30-day revascularization and (2) major adverse cardiac events (MACE). Area under the receiver operating characteristic curve (AUC) was used to compare accuracy of risk prediction. Results Sixty percent of patients had obstructive CAD by QCA with 23% undergoing 30-day revascularization and 9% experiencing MACE at 2 years. Most late events (20/32) were revascularization procedures. Prediction of 30-day revascularization was modest (AUC range 0.67-0.78) but improved after excluding patients with known CAD (AUC range 0.73-0.86, p < 0.05 for all). Similarly, prediction of MACE improved after excluding patients with known CAD (AUC range 0.58-0.73 vs. 0.63-0.77). CT metrics of atherosclerosis burden performed overall similarly but stenosis assessment was superior for predicting 30-day revascularization. Conclusions Angiographic and coronary atherosclerotic plaque metrics perform only modestly well for predicting 30-day revascularization and 2-year MACE in high risk patients but improve after excluding patients with known CAD. Atherosclerotic plaque metrics did not yield incremental value over stenosis assessment for predicting events that predominantly consisted of revascularization procedures. Show less