AimsCustom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection... Show moreAimsCustom triflange acetabular components (CTACs) play an important role in reconstructive orthopaedic surgery, particularly in revision total hip arthroplasty (rTHA) and pelvic tumour resection procedures. Accurate CTAC positioning is essential to successful surgical outcomes. While prior studies have explored CTAC positioning in rTHA, research focusing on tumour cases and implant flange positioning precision remains limited. Additionally, the impact of intraoperative navigation on positioning accuracy warrants further investigation. This study assesses CTAC positioning accuracy in tumour resection and rTHA cases, focusing on the differences between preoperative planning and postoperative implant positions.MethodsA multicentre observational cohort study in Australia between February 2017 and March 2021 included consecutive patients undergoing acetabular reconstruction with CTACs in rTHA (Paprosky 3A/3B defects) or tumour resection (including Enneking P2 peri-acetabular area). Of 103 eligible patients (104 hips), 34 patients (35 hips) were analyzed.ResultsCTAC positioning was generally accurate, with minor deviations in cup inclination (mean 2.7°; SD 2.84°), anteversion (mean 3.6°; SD 5.04°), and rotation (mean 2.1°; SD 2.47°). Deviation of the hip centre of rotation (COR) showed a mean vector length of 5.9 mm (SD 7.24). Flange positions showed small deviations, with the ischial flange exhibiting the largest deviation (mean vector length of 7.0 mm; SD 8.65). Overall, 83% of the implants were accurately positioned, with 17% exceeding malpositioning thresholds. CTACs used in tumour resections exhibited higher positioning accuracy than rTHA cases, with significant differences in inclination (1.5° for tumour vs 3.4° for rTHA) and rotation (1.3° for tumour vs 2.4° for rTHA). The use of intraoperative navigation appeared to enhance positioning accuracy, but this did not reach statistical significance.ConclusionThis study demonstrates favourable CTAC positioning accuracy, with potential for improved accuracy through intraoperative navigation. Further research is needed to understand the implications of positioning accuracy on implant performance and long-term survival. Show less
Koster, L.A.; Kaptein, B.L.; Zwaag, E.H.M.J. van der van der; Nelissen, R.G.H.H. 2024
Purpose: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed‐bearing, posterior‐stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial... Show morePurpose: This clinical fluoroscopy study investigated knee kinematics of two different cemented fixed‐bearing, posterior‐stabilised (PS) total knee arthroplasty (TKA) designs: an asymmetric tibial component including an asymmetric insert designed to optimise personalised balance and fit and its precursor symmetrical design with symmetric insert. Methods: A consecutive series of patients (16 TKAs from each treatment group) participating in a randomised controlled trial comparing TKA migration was included. The exclusion criterion was the use of walking aids. Flat‐panel fluoroscopic recordings of step‐up and lunge motions were acquired 1‐year postoperatively. Medial and lateral contact points (CPs) were determined to calculate CP displacement, femoral axial rotation and pivot position. Using linear mixed‐effects modelling techniques, kinematics between TKA designs were compared. Results: During knee extension between 20° flexion and full extension, the CPs moved anteriorly combined with a small internal femoral rotation (a screw‐home mechanism). Whereas CP movement was reversed: femoral rollback, external femoral rotation while flexing the knee between full extension and 20° knee flexion, At larger flexion angles, femoral axial rotation (FAR) occurred around a lateral pivot point both during step‐up and lunge. The symmetric design had a 2.3° larger range of FAR compared to the asymmetric design during lunge (p = 0.02). All other kinematics were comparable. Conclusion: Despite the differences in design, this study showed that the asymmetric and symmetric PS TKA designs had mostly comparable knee kinematics during step‐up and lunge motions. It is therefore expected that the functionality of the successor TKA design is similar to that of its precursor design. Show less
Kuhrij, L.S.; Marang-van de Mheen, P.J.; Lier, L. van; Alimahomed, R.; Nelissen, R.G.H.H.; Bodegom-Vos, L. van 2024
The use of MRI and arthroscopy are considered low-value care in most patients with degenerative knee disease. To reduce these modalities, there have been multiple efforts to increase awareness.... Show moreThe use of MRI and arthroscopy are considered low-value care in most patients with degenerative knee disease. To reduce these modalities, there have been multiple efforts to increase awareness. Reductions have been shown for general hospitals (GH), but it is unclear whether this may be partly explained by a shift of patients receiving these modalities in independent treatment centers (ITCs). The aims of this study were to assess (i) whether the trend in use of MRI and arthroscopy in patients with degenerative knee disease differs between ITCs and GH, and (ii) whether the Dutch efforts to raise awareness on these recommendations were associated with a change in the trend for both types of providers. All patients insured by a Dutch healthcare insurer aged ≥50 years with a degenerative knee disease who were treated in a GH or ITC between July 2014 and December 2019 were included. Linear regression was used with the quarterly percentage of patients receiving an MRI or knee arthroscopy weighted by center volume, as the primary outcome. Interrupted time-series analysis was used to evaluate the effect of the Dutch efforts to raise awareness. A total of 14 702 patients included were treated in 90 GHs (n = 13 303, 90.5%) and 29 ITCs (n = 1399, 9.5%). Across the study period, ITCs on an average had a 16% higher MRI use (P < .001) and 9% higher arthroscopy use (P = .003). MRI use did not change in both provider types, but arthroscopy use signifcantly decreased and became stronger in ITCs (P = .01). The Dutch efforts to increase awareness did not signifcantly infuence either MRI or arthroscopy use in ITCs (P = .55 and P = .84) and GHs (P = .13 and P = .70). MRI and arthroscopy uses were higher in ITCs than GHs. MRI use did not change signifcantly among patients ≥ 50 years with degenerative knee disease in both provider types between 2014 and 2019. MRI- and arthroscopy use decreased with ITCs on average having higher rates for both modalities, but also showing a stronger decrease in arthroscopy use. The Dutch efforts to increase awareness did not accelerate the already declining trend in the Netherlands. Show less
Hasan, S.; Schie, P. van; Kaptein, B.L.; Schoones, J.W.; Marang-van de Mheen, P.J.M.; Nelissen, R.G.H.H. 2024
Background: Loosening is a major cause for failure of total hip and total knee arthroplasties (THAs/TKAs). Preemptive diagnostics of asymptomatic loosening could open strategies to prevent gross... Show moreBackground: Loosening is a major cause for failure of total hip and total knee arthroplasties (THAs/TKAs). Preemptive diagnostics of asymptomatic loosening could open strategies to prevent gross loosening. A multitude of biomarkers may discriminate between loosened and stable implants, but it is unknown which have the best performance. The present systematic review aimed to assess which biomarkers have shown the most promising results in discriminating between stable and aseptic loosened THAs and TKAs.Methods: PubMed, Embase, Web of Science, Cochrane Library, and Academic Search Premier were systematically searched up to January 2020 for studies including THA/TKA and biomarkers to assess loosening. Two reviewers independently screened records, extracted data, and assessed the risk of bias using the ICROMS tool to classify the quality of the studies.Results: Twenty-eight (three high-quality) studies were included, reporting on a median of 48 patients (interquartile range 28-69). Serum and urine markers were evaluated in 22 and 10 studies, respectively. Tumor necrosis factor alpha and osteocalcin were significantly higher in loosened compared with stable implants. Urinary N-terminal telopeptide had significantly elevated levels in loosened prostheses.Conclusion: Several serum and urine markers were promising in discriminating between loosened and stable implants. We recommend future studies to evaluate these biomarkers in a longitudinal fashion to assess whether progression of loosening is associated with a change in these biomarkers. In particular, high-quality studies assessing the usability of these biomarkers are needed. Show less
Lelij, T.J.N. van der; Koster, L.A.; Mheen, P.J. van de; Toksvig-larsen, S.; Nelissen, R.G.H.H.; Kaptein, B.L. 2024
Background and purpose — Different marker-selection methods are applied to represent implant and tibial seg-ments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA).... Show moreBackground and purpose — Different marker-selection methods are applied to represent implant and tibial seg-ments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of mark-ers throughout subsequent RSA examinations (“consistent-marker method”) is used or all available markers at each follow-up (“all-marker method”). The aim of this secondary analysis was to compare marker-selection methods on indi-vidual and group level TKA migration results.Methods — Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evalu-ated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was cal-culated using 5 fictive points, either plotted based on the con-sistent set of markers or all available markers.Results —Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examina-tions was 0.02 mm, 95% confidence interval –0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrat-ing in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used.Conclusion —Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening. Show less
Background: Various surface modifications are used in uncemented total knee arthroplasties (TKAs) to enhance bony ingrowth and longevity of implants. This study aimed to identify which surface... Show moreBackground: Various surface modifications are used in uncemented total knee arthroplasties (TKAs) to enhance bony ingrowth and longevity of implants. This study aimed to identify which surface modifications are used, whether they are associated with different revision rates for aseptic loosening, and which are underperforming compared to cemented implants.Methods: Data on all cemented and uncemented TKAs used between 2007 and 2021 were obtained from the Dutch Arthroplasty Register. Uncemented TKAs were divided into groups based on their surface modifications. Revision rates for aseptic loosening and major revisions were compared between groups. Kaplan-Meier, Competing-Risk, Log-rank tests, and Cox regression analyses were used. In total, 235,500 cemented and 10,749 uncemented primary TKAs were included. The different uncemented TKA groups included the following: 1,140 porous-hydroxyapatite (HA); 8,450 Porous-uncoated; 702 Grit-blasteduncoated; and 172 Grit-blasted-Titanium-nitride (TiN) implants.Results: The 10-year revision rates for aseptic loosening and major revision of the cemented TKAs were 1.3 and 3.1%, and for uncemented TKAs 0.2 and 2.3% (porous-HA), 1.3 and 2.9% (porous-uncoated), 2.8 and 4.0% (grit-blasted-uncoated), and 7.9% and 17.4% (grit-blasted-TiN), respectively. Both type of revision rates varied significantly between the uncemented groups (log-rank tests, P < .001, P < .001). All grit-blasted implants had a significantly higher risk of aseptic loosening (P < .01), and porous-uncoated implants had a significantly lower risk of aseptic loosening than cemented implants (P 1/4 .03) after 10 years.Conclusion: There were 4 main uncemented surface modifications identified, with different revision rates for aseptic loosening. Implants with porous-HA and porous-uncoated had the best revision rates, at least equal to cemented TKAs. Grit-blasted implants with and without TiN underperformed, possibly due to the interaction of other factors.(c) 2023 Elsevier Inc. All rights reserved. Show less
Lelij, T.J.N. van der; Mheen, P.J. van de; Kaptein, B.L.; Toksvig-Larsen, S.; Nelissen, R.G.H.H. 2023
Background:Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric... Show moreBackground:Three-dimensional (3D) printing of highly porous orthopaedic implants aims to promote better osseointegration, thus preventing aseptic loosening. However, short-term radiostereometric analysis (RSA) after total knee arthroplasty (TKA) has shown higher initial migration of cementless 3D-printed tibial components compared with their cemented counterparts. Therefore, critical evaluation of longer-term tibial component migration is needed. We investigated migration of a cementless 3D-printed and a cemented tibial component with otherwise similar TKA design during 5 years of follow-up, particularly the progression in migration beyond 2 years postoperatively.Methods:Seventy-two patients were randomized to a cementless 3D-printed Triathlon Tritanium (Stryker) cruciate-retaining (CR) TKA or a cemented Triathlon CR (Stryker) TKA implant. Implant migration was evaluated with RSA at baseline and postoperatively at 3 months and at 1, 2, and 5 years. The maximum total point motion (MTPM) of the tibial component was compared between the groups at 5 years, and progression in migration was assessed between 2 and 5 years. Individual implants were classified as continuously migrating if the MTPM was >= 0.1 mm/year beyond 2 years postoperatively. Clinical scores were evaluated, and a linear mixed-effects model was used to analyze repeated measurements.Results:At 5 years, the mean MTPM was 0.66 mm (95% confidence interval [CI], 0.56 to 0.78 mm) for the cementless group and 0.53 mm (95% CI, 0.43 to 0.64 mm) for the cemented group (p = 0.09). Between 2 and 5 years, there was no progression in mean MTPM for the cementless group (0.02 mm; 95% CI, -0.06 to 0.10 mm) versus 0.07 mm (95% CI, 0.00 to 0.14) for the cemented group. One implant was continuously migrating in the cementless group, and 4 were continuously migrating in the cemented group. The clinical scores were comparable between the groups across the entire time of follow-up.Conclusions:No significant difference in mean migration was found at 5 years between the cementless and cemented TKA implants. Progression of tibial component migration was present beyond 2 years for the cemented implant, whereas the cementless implant remained stable after initial early migration.Level of evidence:Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Show less
Background Opioid use before TKA or THA is linked to a higher risk of revision surgery and less functional improvement. In Western countries, the frequency of preoperative opioid use has varied,... Show moreBackground Opioid use before TKA or THA is linked to a higher risk of revision surgery and less functional improvement. In Western countries, the frequency of preoperative opioid use has varied, and robust information on temporal changes in opioid prescriptions over time (in the months before surgery as well as annual changes) and among prescribers is necessary to pinpoint opportunities to improve on low-value care patterns, and when they are recognized, to target physician populations for intervention strategies.Questions/purposes (1) What proportion of patients undergoing arthroplasties receive an opioid prescription in the year before TKA or THA, and what were the preoperative opioid prescription rates over time between 2013 and 2018? (2) Does the preoperative prescription rate vary between 12 and 10 months and between 3 and 1 months in the year before TKA or THA, and did it change between 2013 and 2018? (3) Which medical professionals were the main prescribers of preoperative opioids 1 year before TKA or THA?Methods This was a large-database study drawn from longitudinally maintained national registry sources in the Netherlands. The Dutch Foundation for Pharmaceutical Statistics was linked to the Dutch Arthroplasty Register from 2013 to 2018. TKAs and THAs performed because of osteoarthritis in patients older than 18 years, which were also uniquely linked by age, gender, patient postcode, and low–molecular weight heparin use, were eligible. Between 2013 and 2018, 146,052 TKAs were performed: 96% (139,998) of the TKAs were performed for osteoarthritis in patients older than 18 years; of them, 56% (78,282) were excluded because of our linkage criteria. Some of the linked arthroplasties could not be linked to a community pharmacy, which was necessary to follow patients over time, leaving 28% (40,989) of the initial TKAs as our study population. Between 2013 and 2018, 174,116 THAs were performed: 86% (150,574) were performed for osteoarthritis in patients older than 18 years, one arthroplasty was excluded because of an outlier opioid dose, and a further 57% (85,724 of 150,574) were excluded because of our linkage criteria. Some of the linked arthroplasties could not be linked to a community pharmacy, leaving 28% (42,689 of 150,574) of THAs, which were performed between 2013 and 2018. For both TKA and THA, the mean age before surgery was 68 years, and roughly 60% of the population were women. We calculated the proportion of patients undergoing arthroplasties who had at least one opioid prescription in the year before arthroplasty and compared data from 2013 to 2018. Opioid prescription rates are given as defined daily dosages and morphine milligram equivalents (MMEs) per arthroplasty. Opioid prescriptions were assessed by preoperative quarter and by operation year. Possible changes over time in opioid exposure were investigated using linear regression, adjusted for age and gender, in which the month of operation since January 2013 was used as the determinant and MME as the outcome. This was done for all opioids combined and per opioid type. Possible changes in opioid prescription rates in the year before arthroplasty were assessed by comparing the time period of 1 to 3 months before surgery with the other quarters. Additionally, preoperative prescriptions per operation year were assessed per prescriber category: general practitioners, orthopaedic surgeons, rheumatologists, and others. All analyses were stratified by TKA or THA.Results The proportion of patients undergoing arthroplasties who had an opioid prescription before TKA increased from 25% (1079 of 4298) in 2013 to 28% (2097 of 7460) in 2018 (difference 3% [95% CI 1.35% to 4.65%]; p < 0.001), and before THA increased from 25% (1111 to 4451) to 30% (2323 to 7625) (difference 5% [95% CI 3.8% to 7.2%]; p < 0.001). The mean preoperative opioid prescription rate increased over time between 2013 and 2018 for both TKA and THA. For TKA, an adjusted monthly increase of 3.96 MME was observed (95% CI 1.8 to 6.1 MME; p < 0.001). For THA, the monthly increase was 3.8 MME (95% CI 1.5 to 6.0; p = 0.001. For both TKA and THA, there was a monthly increase in the preoperative oxycodone rate (3.8 MME [95% CI 2.5 to 5.1]; p < 0.001 and 3.6 [95% CI 2.6 to 4.7]; p < 0.001, respectively). For TKA, but not for THA, there was a monthly decrease in tramadol prescriptions (-0.6 MME [95% CI -1.0 to -0.2]; p = 0.006). Regarding the opioids prescribed in the year before surgery, there was a mean increase of 48 MME (95% CI 39.3 to 56.7 MME; p < 0.001) for TKA between 10 and 12 months and the last 3 months before surgery. For THA, this increase was 121 MME (95% CI 110 to 131 MME; p < 0.001). Regarding possible differences between 2013 and 2018, we only found differences in the period 10 to 12 months before TKA (mean difference 61 MME [95% CI 19.2 to 103.3]; p = 0.004) and the period 7 to 9 months before TKA (mean difference 66 MME [95% CI 22.0 to 110.9]; p = 0.003). For THA, there was an increase in the MMEs prescribed between 2013 and 2018 for all four quarters, with mean differences ranging from 43.9 to 55.4 MME (p < 0.05). The average proportion of preoperative opioid prescriptions prescribed by general practitioners ranged between 82% and 86% (41,037 of 49,855 for TKA and 49,137 of 57,289 for THA), between 4% and 6% (2924 of 49,855 for TKA and 2461 of 57,289 for THA), by orthopaedic surgeons, 1% by rheumatologists (409 of 49,855 for TKA and 370 of 57,289 for THA), and between 9% and 11% by other physicians (5485 of 49,855 for TKA and 5321 of 57,289 for THA). Prescriptions by orthopaedic surgeons increased over time, from 3% to 7% for THA (difference 4% [95% CI 3.6 to 4.9]) and 4% to 10% for TKA (difference 6% [95% CI 5% to 7%]; p < 0.001).Conclusion Between 2013 and 2018, preoperative opioid prescriptions increased in the Netherlands, mainly because of a shift to more oxycodone prescriptions. We also observed an increase in opioid prescriptions in the year before surgery. Although general practitioners were the main prescribers of preoperative oxycodone, prescriptions by orthopaedic surgeons also increased during the study period. Orthopaedic surgeons should address opioid use and its associated negative effects in preoperative consultations. More intradisciplinary collaboration seems important to limit the prescribing of preoperative opioids. Additionally, research is necessary to assess whether opioid cessation before surgery reduces the risk of adverse outcomes. Show less
Hoogervorst, L.A.; Stijnen, P.; Albini, M.; Janda, N.; Stewardson, A.J.; Patel, K.; ... ; Marang-van de Mheen, P. 2023
Objectives To assess across seven hospitals from six different countries the extent to which the COVID-19 pandemic affected the volumes of orthopaedic hospital admissions and patient outcomes for... Show moreObjectives To assess across seven hospitals from six different countries the extent to which the COVID-19 pandemic affected the volumes of orthopaedic hospital admissions and patient outcomes for non-COVID-19 patients admitted for orthopaedic care.Design A multi-centre interrupted time series (ITS) analysis.Setting Seven hospitals from six countries who collaborated within the Global Health Data@Work collaborative.Participants Non-COVID-19 patients admitted for orthopaedic care during the pre-pandemic (January/2018-February/2020) and COVID-19 pandemic (March/2020-June/2021) period. Admissions were categorised as: (1) acute admissions (lower limb fractures/neck of femur fractures/pathological fractures/joint dislocations/upper limb fractures); (2) subacute admissions (bone cancer); (3) elective admissions (osteoarthritis).Outcome measures Monthly observed versus expected ratios (O/E) were calculated for in-hospital mortality, long (upper-decile) length-of-stay and hospital readmissions, with expected rates calculated based on case-mix. An ITS design was used to estimate the change in level and/or trend of the monthly O/E ratio by comparing the COVID-19 pandemic with the pre-pandemic period.Results 69221 (pre-pandemic) and 22940 (COVID-19 pandemic) non-COVID-19 orthopaedic patient admissions were included. Admission volumes were reduced during the COVID-19 pandemic for all admission categories (range: 33%-45%), with more complex patients treated as shown by higher percentages of patients admitted with >= 1 comorbidity (53.8% versus 49.8%, p<0.001). The COVID-19 pandemic was not associated with significant changes in patient outcomes for most diagnostic groups. Only for patients diagnosed with pathological fractures (pre-pandemic n=1671and pandemic n=749), the COVID-19 pandemic was significantly associated with an immediate mortality reduction (level change of -77.7%, 95%CI -127.9% to -25.7%) and for lower limb fracture patients (pre-pandemic n=9898and pandemic n=3307) with a significantly reduced trend in readmissions (trend change of -6.3% per month, 95%CI -11.0% to -1.6%).Conclusions Acute, subacute, as well as elective orthopaedic hospital admissions volumes were reduced in all global participating hospitals during the COVID-19 pandemic, while overall patient outcomes for most admitted non-COVID-19 patients remained the same despite the strain caused by the surge of COVID-19 patients. Show less
To investigate factors associated with fulfilment of expectations towards paid employment after total hip/knee arthroplasty (THA/TKA). Cohort study including preoperatively employed patients aged... Show moreTo investigate factors associated with fulfilment of expectations towards paid employment after total hip/knee arthroplasty (THA/TKA). Cohort study including preoperatively employed patients aged 18-64 scheduled for THA/TKA. Expectations were collected preoperatively, and 6 and 12 months postoperatively with the paid employment item of the Hospitalfor-Special-Surgery Expectations Surveys (back-to-normal = 1; large improvement = 2; moderate improvement = 3; slight improvement = 4; not applicable = 5). Patients scoring not applicable were excluded. Fulfilment was calculated by subtracting preoperative from postoperative scores (< 0: unfulfilled; = 0: fulfilled). Multivariable logistic regression analyses were conducted separately for THA/TKA at 6 and 12 months postoperatively. Six months postoperatively, 75% of THA patients (n = 237/ n = 316) and 72% of TKA patients (n = 211/n = 294) had fulfilled expectations. Older age (TKA:OR 1.08, 95% CI 1.01-1.15) and better postoperative physical functioning (THA:OR 1.10, 95% CI 1.06-1.14; TKA:OR 1.03, 95% CI 1.01-1.06) increased the likelihood of fulfilment. Physical work tasks (THA:OR 0.12, 95% CI 0.03-0.44), preoperative sick leave (TKA:OR 0.33, 95% CI 0.17-0.65), and difficulties at work (THA:OR 0.10, 95% CI 0.03- 0.35; TKA:OR 0.41, 95% CI 0.17-0.98) decreased the likelihood of fulfilment. Twelve months postoperatively similar risk factors were found. Three out of four working-age THA/TKA patients had fulfilled expectations towards paid employment at 6 months postoperatively. Preoperative factors associated with fulfilment were older age, mental work tasks, no sick leave, postoperative factors were better physical functioning, and no perceived difficulties at work. Show less
Dysregulation of Wingless and Int-1 (Wnt) signaling has been strongly associated with development and progression of osteoarthritis (OA). Here, we set out to investigate the independent effects of... Show moreDysregulation of Wingless and Int-1 (Wnt) signaling has been strongly associated with development and progression of osteoarthritis (OA). Here, we set out to investigate the independent effects of either mechanical stress (MS) or inflammation on Wnt signaling in human neocartilage pellets, and to relate this Wnt signaling to OA pathophysiology. OA synovium-conditioned media (OAS-CM) was collected after incubating synovium from human end-stage OA joints for 24 h in medium. Cytokine levels in the OAS-CM were determined with a multiplex immunoassay (Luminex). Human neocartilage pellets were exposed to 20% MS, 2% OAS-CM or 1 ng/mL Interleukin-1 & beta; (IL-1 & beta;). Effects on expression levels of Wnt signaling members were determined by reverse transcription-quantitative polymerase chain reaction. Additionally, the expression of these members in articular cartilage from human OA joints was analyzed in association with joint space narrowing (JSN) and osteophyte scores. Protein levels of IL-1 & beta;, IL-6, IL-8, IL-10, tumor necrosis factor & alpha;, and granulocyte-macrophage colony-stimulating factor positively correlated with each other. MS increased noncanonical WNT5A and FOS expression. In contrast, these genes were downregulated upon stimulation with OAS-CM or IL-1 & beta;. Furthermore, Wnt inhibitors DKK1 and FRZB decreased in response to OAS-CM or IL-1 & beta; exposure. Finally, expression of WNT5A in OA articular cartilage was associated with increased JSN scores, but not osteophyte scores. Our results demonstrate that MS and inflammatory stimuli have opposite effects on canonical and noncanonical Wnt signaling in human neocartilage. Considering the extent to which MS and inflammation contribute to OA in individual patients, we hypothesize that targeting specific Wnt pathways offers a more effective, individualized approach. Show less
Objectives: This systematic review and meta-analysis was conducted to assess the outcome of streptococcal hip and knee prosthetic joint infection (PJI) treated with Debridement, Antibiotics and... Show moreObjectives: This systematic review and meta-analysis was conducted to assess the outcome of streptococcal hip and knee prosthetic joint infection (PJI) treated with Debridement, Antibiotics and Implant Retention (DAIR) and to evaluate risk factors associated with failure. Methods: We conducted a systematic literature search on PubMed, Embase, Web of Science, and Cochrane library from inception until October 2021. Random effects meta-analyses (i.e. relative risk) were used to estimate the success rate at the study level and its association with possible risk factors for failure with a specific focus on the use of rifampicin.Results: 25 observational studies were included, incorporating 1367 patients with streptococcal PJIs treated with DAIR. An overall pooled success rate of 71% (95% confidence interval (95%CI) 64-77%) was found for streptococcal PJI treated with DAIR. Treatment success was 76% (95%CI 62% to 91%) for knee PJI and 58% (95%CI 52% to 65%) for hip PJI. Treatment success differed for patients receiving rifampicin (84%, 95% CI 78% to 90%) compared to patients not receiving rifampicin (74%, 95% CI 63% to 85%), but this effect was no longer present in subsequent meta-analyses. Conclusions: The meta-analysis showed no clear benefit for rifampicin administration after DAIR for streptococcal PJI. Better outcome was observed for knee PJI compared to hip PJI. Show less
PurposeTo determine the course of adherence to physical activity (PA) recommendation in hip/knee osteoarthritis patients before and after hip/knee arthroplasty (THA/TKA). Moreover, we explored... Show morePurposeTo determine the course of adherence to physical activity (PA) recommendation in hip/knee osteoarthritis patients before and after hip/knee arthroplasty (THA/TKA). Moreover, we explored predictors for non-adherence 12 months postoperatively.Materials and methodsPrimary THA/TKA were included in a multicenter observational study. Preoperatively and 6/12 months postoperatively, patients reported engagement in moderate-intensity PA in days/week in the past 6 months (PA-recommendation (& GE;30 min of moderate-intensity & GE;5 days/week)). We included predictors stratified by preoperative adherence: sex, age, BMI, comorbidities, smoking, living/working status, season, mental health, HOOS/KOOS subscales before and 6 months postoperatively, and 6-month adherence.Results(1005 THA/972 TKA) Preoperatively, 50% of the population adhered. Adherence increased to 59% at 6 and 12 months. After 12 months, most patients remained at their preoperative PA level, 11% of the preoperative adherers decreased, while 20% of the preoperative non-adherers increased their PA level. In all different groups, adherence to the PA recommendation at 6 months was identified as a predictor (OR-range: 0.16-0.29). In addition, BMI was identified as predictor in the THA adherent (OR = 1.07; 95%CI [1.02-1.15]) and TKA non-adherent groups (OR = 1.08; 95%CI [1.03-1.12]). THA non-adherent group not having paid work (OR = 0.53; 95%CI [0.33-0.85]), and in the TKA adherent group, lower KOOS subscale symptoms (OR = 1.03; 95%CI [1.01-1.05]) were associated with non-adherence.ConclusionsMajority of patients remained at their preoperative PA level. Non-adherence at 6 months was highly predictive for 12-month non-adherence. Show less
With the implementation of the new MDR 2017/745 by the European Parliament, more robust clinical and pre-clinical data will be required due to a more stringent approval process. The EFORT Implant... Show moreWith the implementation of the new MDR 2017/745 by the European Parliament, more robust clinical and pre-clinical data will be required due to a more stringent approval process. The EFORT Implant and Patient Safety Initiative WG1 'Introduction of Innovation', combined knowledge of orthopaedic surgeons, research institutes, orthopaedic device manufacturers, patient representatives and regulatory authorities to develop a comprehensive set of recommendations for the introduction of innovations in joint arthroplasty within the boundaries of MDR 2017/745. Recommendations have been developed to address key questions about pre-clinical and clinical requirements for the introduction of new implants and implant-related instrumentation with the participation of a steering group, invited by the EFORT Board in dialogue with representatives from European National Societies and Speciality Societies. Different degrees of novelty and innovation were described and agreed on in relation to when surgeons can start, using implants and implant-related instrumentation routinely. Before any clinical phase of a new implant, following the pre-market clinical investigation or the equivalent device PMCF pathway, it is a common understanding that all appropriate pre-clinical testing (regulatory mandatory and evident state of the art) - which has to be considered for a specific device - has been successfully completed. Once manufacturers receive the CE mark for a medical device, it can be used in patients routinely when a clinical investigation has been conducted to demonstrate the conformity of devices according to MDR Article 62 or full equivalence for the technical, biological and clinical characteristics has been demonstrated (MDR, Annex XIV, Part A, 3.) and a PMCF study has been initiated. Show less
Summary: Impact of comorbidity on infection risk among hip fracture patients is unclear. We found high incidence of infection. Comorbidity was an important risk factor for infection up to 1 year... Show moreSummary: Impact of comorbidity on infection risk among hip fracture patients is unclear. We found high incidence of infection. Comorbidity was an important risk factor for infection up to 1 year after surgery. Results indicates a need for additional investment in pre- and postoperative programs that assist patients with high comorbidity. Purpose: Comorbidity level and incidence of infection have increased among older patients with hip fracture. The impact of comorbidity on infection risk is unclear. We conducted a cohort study examining the absolute and relative risks of infection in relation to comorbidity level among hip fracture patients. Methods: Utilizing Danish population-based medical registries, we identified 92,600 patients aged >= 65 years undergoing hip fracture surgery between 2004 and 2018. Comorbidity was categorized by Charlson comorbidity index scores (CCI): none (CCI = 0), moderate (CCI = 1-2), or severe (CCI >= 3). Primary outcome was any hospital-treated infection. Secondary outcomes were hospital-treated pneumonia, urinary tract infection, sepsis, reoperation due to surgical-site infection (SSI), and a composite of any hospital- or community-treated infection. We calculated cumulative incidence and hazard ratios (aHRs) adjusted for age, sex, and surgery year, including 95% confidence intervals (CIs). Results: Prevalence of moderate and severe comorbidity was 40% and 19%, respectively. Incidence of any hospital-treated infection increased with comorbidity level within 0-30 days (none 13% vs. severe 20%) and 0-365 days (none 22% vs. 37% severe). Patients with moderate and severe comorbidity, compared to no comorbidity, had aHRs of 1.3 (CI: 1.3-1.4) and 1.6 (CI: 1.5-1.7) within 0-30 days, and 1.4 (CI: 1.4-1.5) and 1.9 (CI: 1.9-2.0) within 0-365, respectively. Highest incidence was observed for any hospital- or community-treated infection (severe 72%) within 0-365 days. Highest aHR was observed for sepsis within 0-365 days (severe vs. none: 2.7 (CI: 2.4-2.9)). Conclusion: Comorbidity is an important risk factor for infection up to 1 year after hip fracture surgery. Show less
Purpose: Effects of clockwise torque rotation onto proximal femoral fracture fixation have been subject of ongoing debate: fixated right-sided trochanteric fractures seem more rotationally stable... Show morePurpose: Effects of clockwise torque rotation onto proximal femoral fracture fixation have been subject of ongoing debate: fixated right-sided trochanteric fractures seem more rotationally stable than left-sided fractures in the biomechanical setting, but this theoretical advantage has not been demonstrated in the clinical setting to date. The purpose of this study was to identify a difference in early reoperation rate between patients undergoing surgery for left-versus right-sided proximal femur fractures using cephalomedullary nailing (CMN). Materials and methods: The American College of Surgeons National Surgical Quality Improvement Program was queried from 2016-2019 to identify patients aged 50 years and older undergoing CMN for a proximal femoral fracture. The primary outcome was any unplanned reoperation within 30 days following surgery. The difference was calculated using a Chi-square test, and observed power calculated using post-hoc power analysis. Results: In total, of 20,122 patients undergoing CMN for proximal femoral fracture management, 1.8% (n=371) had to undergo an unplanned reoperation within 30 days after surgery. Overall, 208 (2.0%) were left-sided and 163 (1.7%) right-sided fractures (p=0.052, risk ratio [RR] 1.22, 95% confidence interval [CI] 1.00-1.50), odds ratio [OR] 1.23 (95%CI 1.00-1.51), power 49.2% (& alpha;=0.05). Conclusion: This study shows a higher risk of reoperation for left-sided compared to right-sided proximal femur fractures after CMN in a large sample size. Although results may be underpowered and statistically insignificant, this finding might substantiate the hypothesis that clockwise rotation during implant insertion and (post-operative) weightbearing may lead to higher reoperation rates. Level of evidence: Therapeutic level II. Show less
Geurkink, T.H.; Bodegom-Vos, L. van; Nagels, J.; Liew, S.; Stijnen, P.; Nelissen, R.G.H.H.; Mheen, P.J. van de 2023
Aims: To evaluate the extent to which publication of high-quality randomised controlled trials(RCTs) in 2018 was associated with a change in volume or trend of subacromial decompression(SAD)... Show moreAims: To evaluate the extent to which publication of high-quality randomised controlled trials(RCTs) in 2018 was associated with a change in volume or trend of subacromial decompression(SAD) surgery in patients with subacromial pain syndrome(SAPS) treated in hospitals across various countries. Methods: Routinely collected administrative data of the Global Health Data@work collaborative were used to identify SAPS patients who underwent SAD surgery in six hospitals from five countries (Australia, Belgium, Netherlands, United Kingdom, United States) between 01/2016 and 02/2020. Following a controlled interrupted time series design, segmented Poisson regression was used to compare trends in monthly SAD surgeries before(01/2016-01/2018) and after(02/2018-02/2020) publication of the RCTs. The control group consisted of musculoskeletal patients undergoing other procedures. Results: A total of 3.046 SAD surgeries were performed among SAPS patients treated in five hospitals; one hospital did not perform any SAD surgeries. Overall, publication of trial results was associated with a significant reduction in the trend to use SAD surgery of 2% per month (Incidence rate ratio (IRR) 0.984[0.971-0.998]; P = 0.021), but with large variation between hospitals. No changes in the control group were observed. However, publication of trial results was also associated with a 2% monthly increased trend (IRR 1.019[1.004-1.034]; P = 0.014) towards other procedures performed in SAPS patients. Conclusion: Publication of RCT results was associated with a significantly decreased trend in SAD surgery for SAPS patients, although large variation between participating hospitals existed and a possible shift in coding practices cannot be ruled out. This highlights the complexities of implementing recommendations to change routine clinical practice even if based on high-quality evidence. Show less
In this systematic review, the antimicrobial effect of ion-substituted calcium phosphate biomaterials was quantitatively assessed.The literature was systematically searched up to the 6th of... Show moreIn this systematic review, the antimicrobial effect of ion-substituted calcium phosphate biomaterials was quantitatively assessed.The literature was systematically searched up to the 6th of December 2021. Study selection and data extraction was performed in duplo by two independent reviewers with a modified version of the OHAT tool for risk of bias assessment. Any differences were resolved by consensus or by a referee. A mixed effects model was used to investigate the relation between the degree of ionic substitution and bacterial reduction.Of 1016 identified studies, 108 were included in the analysis. The methodological quality of included studies ranged from 6 to 16 out of 18 (average 11.4). Selenite, copper, zinc, rubidium, gadolinium, silver and samarium had a clear antimicrobial effect, with a log reduction in bacteria count of 0.23, 1.8, 2.1, 3.6, 5.8, 7.4 and 10 per atomic% of substitution, respectively. There was considerable between-study variation, which could partially be explained by differences in material formulation, study quality and microbial strain. Future research should focus on clinically relevant scenarios in vitro and the translation to in vivo prevention of PJI. Show less
Geurkink, T.H.; Overbeek, C.L.; Marang-van de Mheen, P.J.; Nagels, J.; Nelissen, R.G.H.H.; Groot, J.H. de 2023
Purpose: This study aimed to quantify the extent to which age was associated with joint position sense (JPS) of the asymptomatic shoulder as measured by joint position reproduction (JPR) tasks and... Show morePurpose: This study aimed to quantify the extent to which age was associated with joint position sense (JPS) of the asymptomatic shoulder as measured by joint position reproduction (JPR) tasks and assess the reproducibility of these tasks. Methods: 120 Asymptomatic participants aged 18-70 years each performed 10 JPR-tasks. Both contralateral and ipsilateral JPR-tasks were evaluated on accuracy of JPR under active-and passive conditions at two levels within the shoulder forward flexion trajectory. Each task was performed three times. In a subgroup of 40 participants, the reproducibility of JPR-tasks was assessed one week after initial measurement. Reproducibility of JPR-tasks was evaluated by both reliability (intra-class correlation coefficients (ICC's)) and agreement (standard error of measurement (SEM)) measures. Results: Age was not associated with increased JPR-errors for any of the contralateral or ipsilateral JPR-tasks. ICC's ranged between 0.63 and 0.80 for contralateral JPR-tasks, and from 0.32 to 0.48 for ipsilateral tasks, except for one ipsilateral task where the reliability was similar to contralateral tasks (0.79). The SEM was comparable and small for all JPR-tasks, ranging between 1.1 and 2.1. Conclusion: No age-related decline in JPS of the asymptomatic shoulder was found, and good agreement between test and re-test measurements for all JPR-tasks as indicated by the small SEM. Show less
Geurkink, T.H.; Overbeek, C.L.; Marang-van de Mheen, P.J.; Nagels, J.; Nelissen, R.G.H.H.; Groot, J.H. de 2023
PurposeThis study aimed to quantify the extent to which age was associated with joint position sense (JPS) of the asymptomatic shoulder as measured by joint position reproduction (JPR) tasks and... Show morePurposeThis study aimed to quantify the extent to which age was associated with joint position sense (JPS) of the asymptomatic shoulder as measured by joint position reproduction (JPR) tasks and assess the reproducibility of these tasks.Methods120 Asymptomatic participants aged 18–70 years each performed 10 JPR-tasks. Both contralateral and ipsilateral JPR-tasks were evaluated on accuracy of JPR under active- and passive conditions at two levels within the shoulder forward flexion trajectory. Each task was performed three times. In a subgroup of 40 participants, the reproducibility of JPR-tasks was assessed one week after initial measurement. Reproducibility of JPR-tasks was evaluated by both reliability (intra-class correlation coefficients (ICC’s)) and agreement (standard error of measurement (SEM)) measures.ResultsAge was not associated with increased JPR-errors for any of the contralateral or ipsilateral JPR-tasks. ICC’s ranged between 0.63 and 0.80 for contralateral JPR-tasks, and from 0.32 to 0.48 for ipsilateral tasks, except for one ipsilateral task where the reliability was similar to contralateral tasks (0.79). The SEM was comparable and small for all JPR-tasks, ranging between 1.1 and 2.1.ConclusionNo age-related decline in JPS of the asymptomatic shoulder was found, and good agreement between test and re-test measurements for all JPR-tasks as indicated by the small SEM. Show less