Objectives: To define the instruments for the Assessment of SpondyloArthritis international Society-Outcomes Measures in Rheumatology (ASAS-OMERACT) core domain set for axial spondyloarthritis ... Show moreObjectives: To define the instruments for the Assessment of SpondyloArthritis international Society-Outcomes Measures in Rheumatology (ASAS-OMERACT) core domain set for axial spondyloarthritis (axSpA). Methods: An international working group representing key stakeholders selected the core outcome instruments following a predefined process: (1) identifying candidate instruments using a systematic literature review; (2) reducing the list of candidate instruments by the working group, (3) assessing the instruments' psychometric properties following OMERACT filter 2.2, (4) selection of the core instruments by the working group and (5) voting and endorsement by ASAS. Results: The updated core set for axSpA includes seven instruments for the domains that are mandatory for all trials: Ankylosing Spondylitis Disease Activity Score and Numerical Rate Scale (NRS) patient global assessment of disease activity, NRS total back pain, average NRS of duration and severity of morning stiffness, NRS fatigue, Bath Ankylosing Spondylitis Function Index and ASAS Health Index. There are 9 additional instruments considered mandatory for disease-modifying antirheumatic drugs (DMARDs) trials: MRI activity Spondyloarthritis Research Consortium of Canada (SPARCC) sacroiliac joints and SPARCC spine, uveitis, inflammatory bowel disease and psoriasis assessed as recommended by ASAS, 44 swollen joint count, Maastricht Ankylosing Spondylitis Enthesitis Score, dactylitis count and modified Stoke Ankylosing Spondylitis Spinal Score. The imaging outcomes are considered mandatory to be included in at least one trial for a drug tested for properties of DMARD. Furthermore, 11 additional instruments were also endorsed by ASAS, which can be used in axSpA trials on top of the core instruments. Conclusions: The selection of the instruments for the ASAS-OMERACT core domain set completes the update of the core outcome set for axSpA, which should be used in all trials. Show less
Molto, A.; Lopez-Medina, C.; Bosch, F.E. van den; Boonen, A.; Webers, C.; Dernis, E.; ... ; Dougados, M. 2021
Objectives To compare the benefits of a tight-control/treat-to-target strategy (TC/T2T) in axial spondyloarthritis (axSpA) with those of usual care (UC).Methods Pragmatic, prospective, cluster... Show moreObjectives To compare the benefits of a tight-control/treat-to-target strategy (TC/T2T) in axial spondyloarthritis (axSpA) with those of usual care (UC).Methods Pragmatic, prospective, cluster-randomised, controlled, open, 1-year trial (NCT03043846). 18 centres were randomised (1:1). Patients met Axial Spondylo Arthritis International Society (ASAS) criteria for axSpA, had an Ankylosing Spondylitis Disease Activity Score (ASDAS) >= 2.1, received non-optimal treatment by non-steroidal anti-inflammatory drugs and were biologic-naive.Interventions (1) TC/T2T: visits every 4 weeks and prespecified strategy based on treatment intensification until achieving target (ie, ASDAS <2.1); (2) UC: visits every 12 weeks and treatment at the rheumatologist's discretion.Main outcome Percentage of patients with a >= 30% improvement on the ASAS-Health Index (ASAS-HI). Other efficacy outcomes and adverse events were recorded. A health economic evaluation was performed.Statistical analysis Two-level mixed models were used to estimate efficacy outcomes. Cost-effectiveness was assessed by the incremental cost per quality-adjusted life-year (QALY) gained for TC/T2T versus UC.Results 160 patients were included (80/group). Mean (SD) age was 37.9 (11.0) years and disease duration was 3.7 (6.2) years; 51.2% were men. ASDAS at inclusion was 3.0 (0.7), and ASAS-HI was 8.6 (3.7). ASAS-HI improved by >= 30% in 47.3% of the TC/T2T arm and in 36.1% of those receiving UC (non-significant). All secondary efficacy outcomes were more frequent in the TC/T2T arm, although not all statistically significant. Safety was similar in both arms. From a societal perspective, TC/T2T resulted in an additional 0.04 QALY, and saved euro472 compared with UC.Conclusion TC/T2T was not significantly superior to UC for the primary outcome, while many secondary efficacy outcomes favoured it, had a similar safety profile and was favourable from a societal health economic perspective. Show less
Costantino, F.; Carmona, L.; Boers, M.; Backhaus, M.; Balint, P.V.; Bruyn, G.A.; ... ; D'Agostino, M.A. 2021
Objective To produce European League Against Rheumatism (EULAR) recommendations for the reporting of ultrasound studies in rheumatic and musculoskeletal diseases (RMDs). Methods Based on the... Show moreObjective To produce European League Against Rheumatism (EULAR) recommendations for the reporting of ultrasound studies in rheumatic and musculoskeletal diseases (RMDs). Methods Based on the literature reviews and expert opinion (through Delphi surveys), a taskforce of 23 members (12 experts in ultrasound in RMDs, 9 in methodology and biostatistics together with a patient research partner and a health professional in rheumatology) developed a checklist of items to be reported in every RMD study using ultrasound. This checklist was further refined by involving a panel of 79 external experts (musculoskeletal imaging experts, methodologists, journal editors), who evaluated its comprehensibility, feasibility and comprehensiveness. Agreement on each proposed item was assessed with an 11-point Likert scale, grading from 0 (total disagreement) to 10 (full agreement). Results Two face-to-face meetings, as well as two Delphi rounds of voting, resulted in a final checklist of 23 items, including a glossary of terminology. Twenty-one of these were considered 'mandatory' items to be reported in every study (such as blinding, development of scoring systems, definition of target pathologies) and 2 'optional' to be reported only if applicable, such as possible confounding factors (ie, ambient conditions) or experience of the sonographers. Conclusion An EULAR taskforce developed a checklist to ensure transparent and comprehensive reporting of aspects concerning research and procedures that need to be presented in studies using ultrasound in RMDs. This checklist, if widely adopted by authors and editors, will greatly improve the interpretability of study development and results, including the assessment of validity, generalisability and applicability. Show less