Background and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES)... Show moreBackground and aims: The impact of endothelial shear stress (ESS) on vessel remodeling in vessels implanted with bioresorbable scaffold (BRS) as compared to metallic drug-eluting stent (DES) remains elusive. The aim of this study was to determine whether the relationship between ESS and remodeling patterns differs in BRS from those seen in metallic DES at 3-year follow-up.Methods: In the ABSORB II randomized trial, lesions were investigated by serial coronary angiography and intravascular ultrasound (IVUS). Three-dimensional reconstructions of coronary arteries post-procedure and at 3 years were performed. ESS was quantified using non-Newtonian steady flow simulation. IVUS cross-sections in device segment were matched using identical landmarks.Results: Paired ESS calculations post-procedure and at 3 years were feasible in 57 lesions in 56 patients. Post-procedure, median ESS at frame level was higher in BRS than in DES, with marginal statistical significance (0.97 +/- 0.48 vs. 0.75 +/- 0.39 Pa, p = 0.063). In the BRS arm, vessel area and lumen area showed larger increases in the highest tercile of median ESS post-procedure as compared to the lowest tercile. In contrast, in DES, no significant relationship between median ESS post-procedure and remodeling was observed. In multivariate analysis, smaller vessel area, larger lumen area, higher plaque burden post-procedure, and higher median ESS post-procedure were independently associated with expansive remodeling in matched frames. Only in BRS, younger age was an additional significant predictor of expansive remodeling.Conclusions: In a subset of lesions with large plaque burden, shear stress could be associated with expansive remodeling and late lumen enlargement in BRS, while ESS had no impact on vessel dimension in metallic DES. Show less
Aims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES... Show moreAims: The aim of this study was to assess the acute performance of the 95 mu m ArterioSorb oriented poly L-lactic acid (PLLA) scaffold in comparison with the XIENCE metallic drug-eluting stent (DES) in porcine coronary arteries.Methods and results: In 15 non-atherosclerotic Yucatan mini pigs, the ArterioSorb (3.0/14 mm) and XIENCE (3.0/15 mm) were implanted in 25 and 15 vessels, respectively. Acute performance was evaluated by using quantitative coronary angiography (QCA) and optical coherence tomography (OCT). Following three-dimensional reconstruction of the coronary arteries, endothelial shear stress (ESS) was quantified using non-Newtonian steady-flow simulation. Acute recoil measured by QCA was comparable in the two aims. Post-procedural flow and scaffold/stent area by OCT did not differ between the two devices. ESS post procedure was comparable between ArterioSorb and XIENCE (2.21 +/- 1.97 vs 2.25 +/- 1.71 Pa, p=0.314).Conclusions: Acute recoil, luminal dimensions and ESS in the ArterioSorb oriented PLLA scaffold with thin struts of 95 mu m were comparable to those in the XIENCE metallic DES. Show less
Optical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to... Show moreOptical coherence tomography based computational flow dynamic (CFD) modeling provides detailed information about the local flow behavior in stented/scaffolded vessel segments. Our aim is to investigate the in-vivo effect of strut thickness and strut protrusion on endothelial wall shear stress (ESS) distribution in ArterioSorb Absorbable Drug-Eluting Scaffold (ArterioSorb) and Absorb everolimus-eluting Bioresorbable Vascular Scaffold (Absorb) devices that struts with similar morphology (quadratic structure) but different thickness. In three animals, six coronary arteries were treated with ArterioSorb. At different six animals, six coronary arteries were treated with Absorb. Following three-dimensional(3D) reconstruction of the coronary arteries, Newtonian steady flow simulation was performed and the ESS were estimated. Mixed effects models were used to compare ESS distribution in the two devices. There were 4591 struts in the analyzed 477 cross-sections in Absorb (strut thickness=157 mu m) and 3105 struts in 429 cross-sections in ArterioSorb (strut thickness=95 mu m) for the protrusion analysis. In cross-section level analysis, there was significant difference between the scaffolds in the protrusion distances. The protrusion was higher in Absorb (97% of the strut thickness) than in ArterioSorb (88% of the strut thickness). ESS was significantly higher in ArterioSorb (1.52 +/- 0.34Pa) than in Absorb (0.73 +/- 2.19Pa) (p=0.001). Low- and very-low ESS data were seen more often in Absorb than in ArterioSorb. ArterioSorb is associated with a more favorable ESS distribution compared to the Absorb. These differences should be attributed to different strut thickness/strut protrusion that has significant effect on shear stress distribution. Show less
OBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX ... Show moreOBJECTIVES The aims of the present study were to investigate the applicability of quantitative flow ratio (QFR) in patients with 3-vessel disease and to demonstrate the impact of functional SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score derived from QFR (fSS(QFR)) on clinical outcomes.BACKGROUND The applicability of QFR in patients with 3-vessel disease and the feasibility of fSS(QFR) have not yet been investigated.METHODS All lesions interrogated using instantaneous wave-free ratio and/or fractional flow reserve in the SYNTAX II trial were retrospectively screened and analyzed for QFR. The diagnostic performance of QFR was investigated using hybrid wire-derived pressure assessment (instantaneous wave-free ratio and fractional flow reserve), used in the trial as a reference. Patients with analyzable QFR in 3 vessels were stratified according to fSS(QFR) to evaluate its clinical prognostic value on the basis of 2-year patient-oriented composite endpoint.RESULTS QFRs were analyzable in 71.0% of lesions (836 lesions). The diagnostic performance of QFR to predict binary wire-based ischemia was substantial (area under the curve 0.81, accuracy 73.8%), with a positive predictive value of 85.9%. Independent predictors of diagnostic discordance were lesions in side branches, involvement of bifurcation or trifurcation, and small vessel. According to the 2-year patient-oriented composite endpoint, fSS(QFR) reclassified 26.1% of the patients (36 of 138) in the high-to intermediate-risk group into the low-risk group appropriately (net reclassification improvement 0.32; p < 0.001). The area under the curve for fSS(QFR) to predict the 2-year patient-oriented composite endpoint was higher than that of the classic anatomic SYNTAX score (0.68 vs. 0.56; p = 0.002).CONCLUSIONS QFR demonstrated substantial applicability in patients with 3-vessel disease. The fSS(QFR) has the potential to further refine prognostic risk estimation compared with the classic anatomic SYNTAX score. (c) 2019 by the American College of Cardiology Foundation. Show less