Respiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e... Show moreRespiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e., elective cesarean section) are at greater risk of developing respiratory distress due to elevated airway liquid volumes at birth. These babies are commonly diagnosed with transient tachypnea of the newborn (TTN) and historically treatments have mostly focused on enhancing airway liquid clearance pharmacologically or restricting fluid intake with limited success. Alternatively, a number of clinical studies have investigated the potential benefits of respiratory support in newborns with or at risk of TTN, but there is considerable heterogeneity in study designs and outcome measures. A literature search identified eight clinical studies investigating use of respiratory support on outcomes related to TTN in babies born at term. Study demographics including gestational age, mode of birth, antenatal corticosteroid exposure, TTN diagnosis, timing of intervention (prophylactic/interventional), respiratory support (type/interface/device/pressure), and study outcomes were compared. This narrative review provides an overview of factors within and between studies assessing respiratory support for preventing and/or treating TTN. In addition, we discuss the physiological understanding of how respiratory support aids lung function in newborns with elevated airway liquid volumes at birth. However, many questions remain regarding the timing of onset, pressure delivered, device/interface used and duration, and weaning of support. Future studies are required to address these gaps in knowledge to provide evidenced based recommendations for management of newborns with or at risk of TTN. Show less
Respiratory distress is relatively common in infants born at or near-term, particularly in infants delivered following elective cesarean section. The pathophysiology underlying respiratory distress... Show moreRespiratory distress is relatively common in infants born at or near-term, particularly in infants delivered following elective cesarean section. The pathophysiology underlying respiratory distress at term has largely been explained by a failure to clear airway liquid, but recent physiological evidence has indicated that it results from elevated airway liquid at the onset of air-breathing. We have investigated the effect of elevated airway liquid volumes at birth on cardiorespiratory function in preterm and near-term lambs. Preterm (130 +/- 0 days gestation, term -147 days gestation; n = 12) and near-term (139 +/- 1 days gestation; n = 13) lambs were instrumented (to measure blood pressure, blood flow, and blood gas status) and, at delivery, airway liquid volumes were adjusted to mimic levels expected following vaginal delivery (Controls; similar to 7 mUkg) or elective cesarean section with no labor (elevated liquid (EL); 37 mL/kg). Lambs were delivered, mechanically ventilated, and monitored for blood gas status, oxygenation, ventilator requirements, blood flows (carotid artery and pulmonary artery), and blood pressure during the first few hours of life. Preterm and near-term EL lambs had poorer gas exchange and required greater ventilatory support to maintain adequate oxygenation. Pulmonary blood flow was reduced and carotid artery blood flow, mean arterial blood pressure, and heart rate were reduced in EL near-term but not preterm lambs. These data provide further evidence that greater airway liquid volumes at birth adversely affect newborn cardiorespiratory function, with the effects being greater in near-term newborns.NEW & NOTEWORTHY We provide evidence for adverse effects of elevated airway liquid volumes at birth on pulmonary blood flow and gas exchange in both preterm and near-term lambs, although the effects were greatest in near-term newborns. Our study is an important step toward understanding the fundamental physiology underlying the cardiorespiratory morbidity associated with near-term newborns with elevated airway liquid volumes leading to respiratory distress soon after birth. Show less
Approximately 53% of near-term newborns admitted to intensive care experience respiratory distress. These newborns are commonly delivered by cesarean section and have elevated airway liquid volumes... Show moreApproximately 53% of near-term newborns admitted to intensive care experience respiratory distress. These newborns are commonly delivered by cesarean section and have elevated airway liquid volumes at birth, which can cause respiratory morbidity. We investigated the effect of providing respiratory support with a positive end-expiratory pressure (PEEP) of 8 cmH2O on lung function in newborn rabbit kittens with elevated airway liquid volumes at birth. Near-term rabbits (30 days; term = 32 days) with airway liquid volumes that corresponded to vaginal delivery (∼7 mL/kg, control, n = 11) or cesarean section [∼37 mL/kg; elevated liquid (EL), n = 11] were mechanically ventilated (tidal volume = 8 mL/kg). The PEEP was changed after lung aeration from 0 to 8 to 0 cmH2O (control, n = 6; EL, n = 6), and in a separate group of kittens, PEEP was changed after lung aeration from 8 to 0 to 8 cmH2O (control, n = 5; EL, n = 5). Lung function (ventilator parameters, compliance, lung gas volumes, and distribution of gas within the lung) was evaluated using plethysmography and synchrotron-based phase-contrast X-ray imaging. EL kittens initially receiving 0 cmH2O PEEP had reduced functional residual capacities and lung compliance, requiring higher inflation pressures to aerate the lung compared with control kittens. Commencing ventilation with 8 cmH2O PEEP mitigated the adverse effects of EL, increasing lung compliance, functional residual capacity, and the uniformity and distribution of lung aeration, but did not normalize aeration of the distal airways. Respiratory support with PEEP supports lung function in near-term newborn rabbits with elevated airway liquid volumes at birth who are at a greater risk of suffering respiratory distress.NEW & NOTEWORTHY Term babies born by cesarean section have elevated airway liquid volumes, which predisposes them to respiratory distress. Treatments targeting molecular mechanisms to clear lung liquid are ineffective for term newborn respiratory distress. We showed that respiratory support with an end-expiratory pressure supports lung function in near-term rabbits with elevated airway liquid volumes at birth. This study provides further physiological understanding of lung function in newborns with elevated airway liquid volumes at risk of respiratory distress. Show less
BACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC).METHODS:... Show moreBACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC).METHODS: Preterm rabbits delivered at 29/32 days (similar to 26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing similar to 2 cm H2O/min) for up to 10 min after birth.RESULTS: FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates.CONCLUSION: In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O. Show less
Background Delayed umbilical cord clamping (UCC) after birth is thought to cause placental to infant blood transfusion, but the mechanisms are unknown. It has been suggested that uterine... Show moreBackground Delayed umbilical cord clamping (UCC) after birth is thought to cause placental to infant blood transfusion, but the mechanisms are unknown. It has been suggested that uterine contractions force blood out of the placenta and into the infant during delayed cord clamping. We have investigated the effect of uterine contractions, induced by maternal oxytocin administration, on umbilical artery (UA) and venous (UV) blood flows before and after ventilation onset to determine whether uterine contractions cause placental transfusion in preterm lambs.Methods and findingsAt similar to 128 days of gestation, UA and UV blood flows, pulmonary arterial blood flow (PBF) and carotid arterial (CA) pressures and blood flows were measured in three groups of fetal sheep during delayed UCC; maternal oxytocin following mifepristone, mifepristone alone, and saline controls. Each successive uterine contraction significantly (p<0.05) decreased UV (26.2 +/- 6.0 to 14.1 +/- 4.5 mL.min(-1).kg(-1)) and UA (41.2 +/- 6.3 to 20.7 +/- 4.0 mL.min(-1).kg(-1)) flows and increased CA pressure and flow (47.1 +/- 3.4 to 52.8 +/- 3.5 mmHg and 29.4 +/- 2.6 to 37.3 +/- 3.4 mL.min(-1).kg(-1)). These flows and pressures were partially restored between contractions, but did not return to pre-oxytocin administration levels. Ventilation onset during DCC increased the effects of uterine contractions on UA and UV flows, with retrograde UA flow (away from the placenta) commonly occurring during diastole.ConclusionsWe found no evidence that amplification of uterine contractions with oxytocin increase placental transfusion during DCC. Instead they decreased both UA and UV flow and caused a net loss of blood from the lamb. Uterine contractions did, however, have significant cardiovascular effects and reduced systemic and cerebral oxygenation. Show less
Respiratory support is critically important for survival of newborns who fail to breathe spontaneously at birth. Although there is no internationally accepted definition of a sustained inflation ... Show moreRespiratory support is critically important for survival of newborns who fail to breathe spontaneously at birth. Although there is no internationally accepted definition of a sustained inflation (SI), it has commonly been defined as a positive pressure inflation designed to establish functional residual capacity and applied over a longer time period than normally used in standard respiratory support (SRS). Outcomes vary distinctly between studies and to date there has been no comprehensive investigation of differences in SI approach and study outcome in both pre-clinical and clinical studies. A systematic literature search was performed and, after screening, identified 17 animal studies and 17 clinical studies evaluating use of a SI in newborns compared to SRS during neonatal resuscitation. Study demographics including gestational age, SI parameters (length, repetitions, pressure, method of delivery) and study outcomes were compared. Animal studies provide mechanistic understanding of a SI on the physiology underpinning the cardiorespiratory transition at birth. In clinical studies, there is considerable difference in study quality, delivery of SIs (number, pressure, length) and timing of primary outcome evaluation which limits direct comparison between studies. The largest difference is method of delivery, where the role of a SI has been observed in intubated animals, as the inflation pressure is directly applied to the lung, bypassing the obstructed upper airway in an apnoeic state. This highlights a potential limitation in clinical use of a SI applied non-invasively. Further research is required to identify if a SI may have greater benefits in subpopulations of newborns. Show less
Background: Physiologic-based cord clamping (PBCC) involves deferring umbilical cord clamping until after lung aeration. It is unclear if infant is at risk of becoming hypothermic during PBCC... Show moreBackground: Physiologic-based cord clamping (PBCC) involves deferring umbilical cord clamping until after lung aeration. It is unclear if infant is at risk of becoming hypothermic during PBCC.Objectives: To test if PBCC would maintain core temperature more effectively than immediate cord clamping (ICC).Design: At 0.93 gestation, fetal lambs were surgically exteriorized and instrumented from pregnant ewes under general anesthesia. Prior to the start of the experiment, lambs were thoroughly dried, placed on hot water bottles, and core temperature was continuously monitored using a rectal thermometer. PBCC lambs (n = 21), received intermittent positive pressure ventilation (iPPV) for >= 5 min prior to umbilical cord clamping. In ICC lambs (n = 23), iPPV commenced within 60 s after umbilical cord clamping. iPPV was provided with heated/humidified gas. Lambs were moved under a radiant warmer after umbilical cord clamping. Additional warmth was provided using a plastic overlay, hairdryer, and extra water bottles, as needed. Two-way mixed and repeated measures one-way ANOVAs were used to compare temperature changes between and within a single group, respectively, over time.Results: Basal fetal parameters including core temperature were similar between groups. ICC lambs had a significant reduction in temperature compared to PBCC lambs (p < 0.001), evident by 1 min (p = 0.002). ICC lambs decreased temperature by 0.51 degrees C (+/- 0.42) and 0.79 degrees C (+/- 0.55) at 5 and 10 min respectively (p < 0.001). In PBCC lambs, temperature did not significantly change before or after umbilical cord clamping (p = 0.4 and p = 0.3, respectively).Conclusions: PBCC stabilized core temperature at delivery better than ICC in term lambs. Hypothermia may not be a significant risk during PBCC. Show less
Preterm newborns commonly receive intermittent positive pressure ventilation (iPPV) at birth, but the optimal approach that facilitates uniform lung aeration is unknown, particularly in a partially... Show morePreterm newborns commonly receive intermittent positive pressure ventilation (iPPV) at birth, but the optimal approach that facilitates uniform lung aeration is unknown, particularly in a partially aerated lung. As both inflation time and exogenous surfactant facilitate uniform lung aeration, we investigated whether they can improve lung aeration and lung mechanics in a partially aerated lung immediately after birth. Preterm rabbit kittens (29 days of gestation, term similar to 32 days) were delivered by caesarean section and partial lung aeration was created by intubating and mechanically ventilating the right lung. The tube was then withdrawn to ventilate both lungs using inflation times of 0.2 s or 1.0 s, with or without exogenous surfactant (200 mg/kg; Curosurf) and a tidal volume (Vt) of 8 mL/kg. Simultaneous phase contrast X-ray imaging and plethysmography were used to measure lung aeration and mechanics. Kittens ventilated with longer inflation times (1.0 s) reached their target Vt with fewer inflations, required lower inflation pressures (28.5 +/- 1.1 vs. 33.5 +/- 1.3 cmH(2)O, P = 0.01) and had higher dynamic lung compliances (0.54 +/- 0.3 vs. 0.40 +/- 0.3 cmH(2)O.mL(-1).kg(-1), P = 0.003). Surfactant increased functional residual capacity (FRC; 31.9 +/- 3.2 vs. 18.0 +/- 3.9 mL/kg, P = 0.02) and the proportion of the Vt entering the previously unaerated lung but had no effect on dynamic lung compliance. Combining early surfactant treatment with longer inflation times increases FRC levels, improves dynamic lung compliance, reduces inflation pressures and markedly increases the proportion of the lungs being ventilated during iPPV in preterm kittens with a partially aerated lung.NEW & NOTEWORTHY Preterm newborns commonly receive intermittent positive pressure ventilation (iPPV) at birth, but the optimal approach that facilitates uniform lung aeration is unknown, particularly in a partially aerated lung. Using phase contrast X-ray imaging, we showed that combining a long inflation time (1.0 s) with surfactant improved lung mechanics and aeration in the immediate newborn period. The current clinical practice of using short inflation times during iPPV might be suboptimal and a different approach is needed. Show less
Introduction During delayed umbilical cord clamping, the factors underpinning placental transfusion remain unknown. We hypothesised that reductions in thoracic pressure during inspiration would... Show moreIntroduction During delayed umbilical cord clamping, the factors underpinning placental transfusion remain unknown. We hypothesised that reductions in thoracic pressure during inspiration would enhance placental transfusion in spontaneously breathing preterm lambs.Objective Investigate the effect of spontaneous breathing on umbilical venous flow and body weight in preterm lambs.Methods Pregnant sheep were instrumented at 132-133 days gestational age to measure fetal common umbilical venous, pulmonary and cerebral blood flows as well as arterial and intrapleural (IP) pressures. At delivery, doxapram and caffeine were administered to promote breathing. Lamb body weights were measured continuously and breathing was assessed by IP pressure changes.Results In 6 lambs, 491 out of 1117 breaths were analysed for change in body weight. Weight increased in 46.6% and decreased in 47.5% of breaths. An overall mean increase of 0.02 +/- 2.5 g per breath was calculated, and no net placental transfusion was observed prior to cord clamping (median difference in body weight 52.3 [-54.9-166.1] g, p=0.418). Umbilical venous (UV) flow transiently decreased with each inspiration, and in some cases ceased, before UV flow normalised during expiration. The reduction in UV flow was positively correlated with the standardised reduction in (IP) pressure, increasing by 109 mL/min for every SD reduction in IP pressure. Thus, the reduction in UV flow was closely related to inspiratory depth.Conclusions Spontaneous breathing had no net effect on body weight in preterm lambs at birth. UV blood flow decreased as inspiratory effort increased, possibly due to constriction of the inferior vena cava caused by diaphragmatic contraction, as previously observed in human fetuses. Show less
Dekker, J.; Martherus, T.; Lopriore, E.; Giera, M.; McGillick, E.V.; Hutten, J.; ... ; Pas, A.B. te 2019
Introduction: During delayed umbilical cord clamping, the factors underpinning placental transfusion remain unknown. We hypothesised that reductions in thoracic pressure during inspiration would... Show moreIntroduction: During delayed umbilical cord clamping, the factors underpinning placental transfusion remain unknown. We hypothesised that reductions in thoracic pressure during inspiration would enhance placental transfusion in spontaneously breathing preterm lambs.Objective: Investigate the effect of spontaneous breathing on umbilical venous flow and body weight in preterm lambs.Methods: Pregnant sheep were instrumented at 132-133 days gestational age to measure fetal common umbilical venous, pulmonary and cerebral blood flows as well as arterial and intrapleural (IP) pressures. At delivery, doxapram and caffeine were administered to promote breathing. Lamb body weights were measured continuously and breathing was assessed by IP pressure changes.Results: In 6 lambs, 491 out of 1117 breaths were analysed for change in body weight. Weight increased in 46.6% and decreased in 47.5% of breaths. An overall mean increase of 0.02±2.5 g per breath was calculated, and no net placental transfusion was observed prior to cord clamping (median difference in body weight 52.3 [-54.9-166.1] g, p=0.418). Umbilical venous (UV) flow transiently decreased with each inspiration, and in some cases ceased, before UV flow normalised during expiration. The reduction in UV flow was positively correlated with the standardised reduction in (IP) pressure, increasing by 109 mL/min for every SD reduction in IP pressure. Thus, the reduction in UV flow was closely related to inspiratory depth.Conclusions: Spontaneous breathing had no net effect on body weight in preterm lambs at birth. UV blood flow decreased as inspiratory effort increased, possibly due to constriction of the inferior vena cava caused by diaphragmatic contraction, as previously observed in human fetuses.Keywords: animal research; neonatology; physiology; placental transfusion; resuscitation Show less
Dekker, J.; Hooper, S.B.; Giera, M.; McGillick, E.V.; Hutten, G.J.; Onlands, W.; ... ; Pas, A.B. te 2019
Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing,... Show moreBackground: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4–28) vs. 38 (29–46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2–50.1%) vs. 27.5% (18.6–36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified. Show less