No replicating evidence for anti-amyloid-β autoantibodies in cerebral amyloid angiopathy-related inflammation
Objective
Elevated levels of anti-amyloid-β (anti-Aβ) autoantibodies in cerebrospinal fluid (CSF) have been proposed as a diagnostic biomarker for cerebral amyloid angiopathy-related inflammation (CAA-RI). We aimed to independently validate the immunoassay for quantifying these antibodies and evaluate its diagnostic value for CAA-RI.
Methods
We replicated the immunoassay to detect CSF anti-Aβ autoantibodies using CSF from CAA-RI patients and non-CAA controls with unrelated disorders and further characterized its performance. Moreover, we conducted a literature review of CAA-RI case reports to investigate neuropathological and CSF evidence of the nature of the inflammatory reaction in CAA-RI.
Results
The assay demonstrated a high background signal in CSF, which increased and corresponded with higher total immunoglobulin G (IgG) concentration in CSF (rsp = 0.51, p = 0.02). Assay levels were not elevated in CAA-RI...
Show moreObjective
Elevated levels of anti-amyloid-β (anti-Aβ) autoantibodies in cerebrospinal fluid (CSF) have been proposed as a diagnostic biomarker for cerebral amyloid angiopathy-related inflammation (CAA-RI). We aimed to independently validate the immunoassay for quantifying these antibodies and evaluate its diagnostic value for CAA-RI.
Methods
We replicated the immunoassay to detect CSF anti-Aβ autoantibodies using CSF from CAA-RI patients and non-CAA controls with unrelated disorders and further characterized its performance. Moreover, we conducted a literature review of CAA-RI case reports to investigate neuropathological and CSF evidence of the nature of the inflammatory reaction in CAA-RI.
Results
The assay demonstrated a high background signal in CSF, which increased and corresponded with higher total immunoglobulin G (IgG) concentration in CSF (rsp = 0.51, p = 0.02). Assay levels were not elevated in CAA-RI patients (n = 6) compared to non-CAA controls (n = 20; p = 0.64). Literature review indicated only occasional presence of B-lymphocytes and plasma cells (i.e., antibody-producing cells), alongside the abundant presence of activated microglial cells, T-cells, and other monocyte lineage cells. CSF analysis did not convincingly indicate intrathecal IgG production.
Interpretation
We were unable to reproduce the reported elevation of anti-Aβ autoantibody concentration in CSF of CAA-RI patients. Our findings instead support nonspecific detection of IgG levels in CSF by the assay. Reviewed CAA-RI case reports suggested a widespread cerebral inflammatory reaction. In conclusion, our findings do not support anti-Aβ autoantibodies as a diagnostic biomarker for CAA-RI.
Show less- All authors
- Berg, E. van den; Roelofs, R.; Jäkel, L.; Greenberg, S.M.; Charidimou, A.; Etten, E.S. van; Boche, D.; Klijn, C.J.M.; Schreuder, F.H.B.M.; Kuiperij, H.B.; Verbeek, M.M.
- Date
- 2024-10-31
- Volume
- 11
- Issue
- 10
- Pages
- 2563 - 2571