Documents
-
- Download
- jcm-09-00190
- Publisher's Version
- open access
- Full text at publishers site
In Collections
This item can be found in the following collections:
Diagnostic accuracy of stool tests for colorectal cancer surveillance in Hodgkin lymphoma survivors
Background: Hodgkin lymphoma (HL) survivors have an increased colorectal cancer (CRC) risk. Diagnostic accuracy of quantitative fecal immunochemical testing (FIT, OC Sensor) and/or a multi-target stool DNA test (mt-sDNA, Cologuard®) for advanced neoplasia (AN) was evaluated.
Methods: 101 HL survivors underwent a surveillance colonoscopy and were asked to perform two stool tests (FIT and mt-sDNA). Advanced adenoma (AA), advanced serrated lesion (ASL), and AN (AA, ASL, CRC) were evaluated. Sensitivity, specificity, and area under the curve (AUC) for AN were calculated for different FIT cut-offs and mt-sDNA with colonoscopy as reference.
Results: FIT and mt-sDNA were analyzed in 73 (72%) and 82 (81%) participants, respectively. AN was detected in 19 (26%) and 22 (27%), respectively. AN sensitivities for FIT cut-off of 10 ug Hb/g feces (FIT10) and mt-sDNA were 37% (95% confidence interval (CI): 16-62) and 68% (95% CI: 45...
Show moreBackground: Hodgkin lymphoma (HL) survivors have an increased colorectal cancer (CRC) risk. Diagnostic accuracy of quantitative fecal immunochemical testing (FIT, OC Sensor) and/or a multi-target stool DNA test (mt-sDNA, Cologuard®) for advanced neoplasia (AN) was evaluated.
Methods: 101 HL survivors underwent a surveillance colonoscopy and were asked to perform two stool tests (FIT and mt-sDNA). Advanced adenoma (AA), advanced serrated lesion (ASL), and AN (AA, ASL, CRC) were evaluated. Sensitivity, specificity, and area under the curve (AUC) for AN were calculated for different FIT cut-offs and mt-sDNA with colonoscopy as reference.
Results: FIT and mt-sDNA were analyzed in 73 (72%) and 82 (81%) participants, respectively. AN was detected in 19 (26%) and 22 (27%), respectively. AN sensitivities for FIT cut-off of 10 ug Hb/g feces (FIT10) and mt-sDNA were 37% (95% confidence interval (CI): 16-62) and 68% (95% CI: 45-86), with corresponding specificities of 91% (95% CI: 80-97) and 70% (95% CI: 57-86), respectively. AUC for FIT was 0.68 (95% CI: 0.54-0.82) and for mt-sDNA 0.76 (95% CI: 0.63-0.89).
Conclusions: In HL survivors, mt-sDNA showed highest sensitivity but with relatively low specificity for AN. Cost-effectiveness analyses is necessary to determine the optimal surveillance strategy.
Show less- All authors
- Ykema, B.; Rigter, L.; Spaander, M.; Moons, L.; Bisseling, T.; Aleman, B.; Boer, J.P. de; Lugtenburg, P.; Janus, C.; Petersen, E.; Roesink, J.; Raemaekers, J.; Maazen, R. van der; Lansdorp-Vogelaar, I.; Gini, A.; Verbeek, W.; Lemmens, M.; Meijer, G.; Leeuwen, F. van; Snaebjornsson, P.; Carvalho, B.; Leerdam, M. van
- Date
- 2020
- Journal
- Journal of Clinical Medicine
- Volume
- 9
- Issue
- 1