Objective: The accessibility of acute care services is currently under pressure, and one way to improve services is better integration. Adequate methodology will be required to provide for a clear... Show moreObjective: The accessibility of acute care services is currently under pressure, and one way to improve services is better integration. Adequate methodology will be required to provide for a clear and accessible evaluation of the various intervention initiatives. The aim of this paper is to develop and propose a Population Health Management(PHM) methodology framework for evaluation of transitions in acute care services. Results: Our methodological framework is developed from several concepts found in literature, including Triple Aim, integrated care and PHM, and includes continuous monitoring of results at both project and population levels. It is based on a broad view of health rather than focusing on a specific illness and facilitates the evaluation of various intervention initiatives in acute care services in the Netherlands and distinctly explains every step of the evaluation process and can be applied to a heterogeneous group of patients. Show less
Assadi, H.; Grafton-Clarke, C.; Demirkiran, A.; Geest, R.J. van der; Nijveldt, R.; Flather, M.; ... ; Garg, P. 2022
Objectives: Mitral regurgitation (MR) and microvascular obstruction (MVO) are common complications of myocardial infarction (MI). This study aimed to investigate the association between MR in ST... Show moreObjectives: Mitral regurgitation (MR) and microvascular obstruction (MVO) are common complications of myocardial infarction (MI). This study aimed to investigate the association between MR in ST-elevation MI (STEMI) subjects with MVO post-reperfusion. STEMI subjects undergoing primary percutaneous intervention were enrolled. Cardiovascular magnetic resonance (CMR) imaging was performed within 48-hours of initial presentation. 4D flow images of CMR were analysed using a retrospective valve tracking technique to quantify MR volume, and late gadolinium enhancement images of CMR to assess MVO. Results: Among 69 patients in the study cohort, 41 had MVO (59%). Patients with MVO had lower left ventricular (LV) ejection fraction (EF) (42 +/- 10% vs. 52 +/- 8%, P < 0.01), higher end-systolic volume (98 +/- 49 ml vs. 73 +/- 28 ml, P < 0.001) and larger scar volume (26 +/- 19% vs. 11 +/- 9%, P < 0.001). Extent of MVO was associated with the degree of MR quantified by 4D flow (R = 0.54, P = 0.0003). In uni-variate regression analysis, investigating the association of CMR variables to the degree of acute MR, only the extent of MVO was associated (coefficient = 0.27, P = 0.001). The area under the curve for the presence of MVO was 0.66 (P = 0.01) for MR > 2.5 ml. We conclude that in patients with reperfused STEMI, the degree of acute MR is associated with the degree of MVO. Show less
Objective Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional... Show moreObjective Doppler echocardiographic aortic valve peak velocity and peak pressure gradient assessment across the aortic valve (AV) is the mainstay for diagnosing aortic stenosis. Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is emerging as a valuable diagnostic tool for estimating the peak pressure drop across the aortic valve, but assessment remains cumbersome. We aimed to validate a novel semi-automated pipeline 4D flow CMR method of assessing peak aortic value pressure gradient (AVPG) using the commercially available software solution, CAAS MR Solutions, against invasive angiographic methods. Results We enrolled 11 patients with severe AS on echocardiography from the EurValve programme. All patients had pre-intervention doppler echocardiography, invasive cardiac catheterisation with peak pressure drop assessment across the AV and 4D flow CMR. The peak AVPG was 51.9 +/- 35.2 mmHg using the invasive pressure drop method and 52.2 +/- 29.2 mmHg for the 4D flow CMR method (semi-automated pipeline), with good correlation between the two methods (r = 0.70, p = 0.017). Assessment of AVPG by 4D flow CMR using the novel semi-automated pipeline method shows excellent agreement to invasive assessment when compared to doppler-based methods and advocate for its use as complementary to echocardiography. Show less
Grafton-Clarke, C.; Crandon, S.; Westenberg, J.J.M.; Swoboda, P.P.; Greenwood, J.P.; Geest, R.J. van der; ... ; Garg, P. 2021
Objectives Four-dimensional flow CMR allows for a comprehensive assessment of the blood flow kinetic energy of the ventricles of the heart. In comparison to standard two-dimensional image... Show moreObjectives Four-dimensional flow CMR allows for a comprehensive assessment of the blood flow kinetic energy of the ventricles of the heart. In comparison to standard two-dimensional image acquisition, 4D flow CMR is felt to offer superior reproducibility, which is important when repeated examinations may be required. The objective was to evaluate the inter-observer and intra-observer reproducibility of blood flow kinetic energy assessment using 4D flow of the left ventricle in 20 healthy volunteers across two centres in the United Kingdom and the Netherlands. Data description This dataset contains 4D flow CMR blood flow kinetic energy data for 20 healthy volunteers with no known cardiovascular disease. Presented is kinetic energy data for the entire cardiac cycle (global), the systolic and diastolic components, in addition to blood flow kinetic energy for both early and late diastolic filling. This data is available for reuse and would be valuable in supporting other research, such as allowing for larger sample sizes with more statistical power for further analysis of these variables. Show less
Liem, M.; Regensburg-Tuïnk, T.; Henkel, C.; Jansen, H.; Spaink, H. 2021
ObjectiveCurrently the majority of non-culturable microbes in sea water are yet to be discovered, Nanopore offers a solution to overcome the challenging tasks to identify the genomes and complex... Show moreObjectiveCurrently the majority of non-culturable microbes in sea water are yet to be discovered, Nanopore offers a solution to overcome the challenging tasks to identify the genomes and complex composition of oceanic microbiomes. In this study we evaluate the utility of Oxford Nanopore Technologies (ONT) sequencing to characterize microbial diversity in seawater from multiple locations. We compared the microbial species diversity of retrieved environmental samples from two different locations and time points.ResultsWith only three ONT flow cells we were able to identify thousands of organisms, including bacteriophages, from which a large part at species level. It was possible to assemble genomes from environmental samples with Flye. In several cases this resulted in>1 Mbp contigs and in the particular case of a Thioglobus singularis species it even produced a near complete genome. k-mer analysis reveals that a large part of the data represents species of which close relatives have not yet been deposited to the database. These results show that our approach is suitable for scalable genomic investigations such as monitoring oceanic biodiversity and provides a new platform for education in biodiversity. Show less
BackgroundSensitivity and throughput of transcriptomic and proteomic technologies have advanced tremendously in recent years. With the use of deep sequencing of RNA samples (RNA-seq) and mass... Show moreBackgroundSensitivity and throughput of transcriptomic and proteomic technologies have advanced tremendously in recent years. With the use of deep sequencing of RNA samples (RNA-seq) and mass spectrometry technology for protein identification and quantitation, it is now feasible to compare gene and protein expression on a massive scale and for any organism for which genomic data is available. Although these technologies are currently applied to many research questions in various model systems ranging from cell cultures to the entire organism level, there are few comparative studies of these technologies in the same system, let alone on the same samples. Here we present a comparison between gene and protein expression in embryos of zebrafish, which is an upcoming model in disease studies.ResultsWe compared Agilent custom made expression microarrays with Illumina deep sequencing for RNA analysis, showing as expected a high degree of correlation of expression of a common set of 18,230 genes. Gene expression was also found to correlate with the abundance of 963 distinct proteins, with several categories of genes as exceptions. These exceptions include ribosomal proteins, histones and vitellogenins, for which biological and technical explanations are discussed.ConclusionsBy comparing state of the art transcriptomic and proteomic technologies on samples derived from the same group of organisms we have for the first time benchmarked the differences in these technologies with regard to sensitivity and bias towards detection of particular gene categories in zebrafish. Our datasets submitted to public repositories are a good starting point for researchers interested in disease progression in zebrafish at a stage of development highly suited for high throughput screening technologies. Show less