Sequential optimal experimental design for X-ray CT using reinforcement learning

Abstract

This thesis develops reinforcement learning methods to make X-ray computed tomography (CT) more efficient for industrial inspection. It frames scanning as a sequential optimal experimental design problem, where each measurement is chosen using information gathered from previous measurements.

The research introduces adaptive strategies for selecting informative projection angles, improving the detection of defects such as cracks and pores, deciding when enough measurements have been collected, and allocating radiation dose across viewing angles. Policies are trained offline, enabling fast decisions during scanning. A reconstruction method accounts for differences in dose between projections.

Experiments on simulated objects demonstrate improvements in reconstruction quality and defect visibility through adaptive acquisition. Laboratory measurements also provide initial evidence that policies trained in simulation can transfer to experimental data. The findings support more efficient, task-specific CT scanning, while identifying challenges for practical deployment, including complex industrial objects, realistic noise, and extension to three-dimensional scanning.

X-ray computed tomographyOptimal experimental designReinforcement learningAdaptive projection selection