Large-scale dose evaluation of deep learning organ contours in head-and-neck radiotherapy by leveraging existing plans
Abstract
Background and purposeRetrospective dose evaluation for organ-at-risk auto-contours has previously used small cohorts due to additional manual effort required for treatment planning on auto-contours. We aimed to do this at large scale, by a) proposing and assessing an automated plan optimization workflow that used existing clinical plan parameters and b) using it for head-and-neck auto-contour dose evaluation.
Materials and methodsOur automated workflow emulated our clinicβs treatment planning protocol and reused existing clinical plan optimization parameters. This workflow recreated the original clinical plan (πππΊ) with manual contours (πππΆ) and evaluated the dose effect (πππΊβπππΆ) on 70 photon and 30 proton plans of head-and-neck patients. As a use-case, the same workflow (and parameters) created a plan using auto-contours (ππ΄πΆ) of eight head-and-neck organs-at-risk from a commercial tool and evaluated their dose effect (πππΆβππ΄πΆ).
ResultsFor plan recreation (πππΊβπππΆ), our workflow had a median impact of 1.0% and 1.5% across dose metrics of auto-contours, for photon and proton respectively. Computer time of automated planning was 25% (photon) and 42% (proton) of manual planning time. For auto-contour evaluation (πππΆβππ΄πΆ), we noticed an impact of 2.0% and 2.6% for photon and proton radiotherapy. All evaluations had a median ΞNTCP (Normal Tissue Complication Probability) less than 0.3%. ConclusionsThe plan replication capability of our automated program provides a blueprint for other clinics to perform auto-contour dose evaluation with large patient cohorts. Finally, despite geometric differences, auto-contours had a minimal median dose impact, hence inspiring confidence in their utility and facilitating their clinical adoption.